摩洛哥人口中小儿头部患者的尺寸特征:建立与年龄相关的关系,准确估计 CT 剂量

IF 1.4 4区 医学 Q4 ENVIRONMENTAL SCIENCES Radioprotection Pub Date : 2024-05-15 DOI:10.1051/radiopro/2024017
H. Sekkat, K. Elmansouri, A. Khallouqi, A. Halimi, O. El rhazouani, Z. Tahiri, M. Talbi, M. El Mansouri
{"title":"摩洛哥人口中小儿头部患者的尺寸特征:建立与年龄相关的关系,准确估计 CT 剂量","authors":"H. Sekkat, K. Elmansouri, A. Khallouqi, A. Halimi, O. El rhazouani, Z. Tahiri, M. Talbi, M. El Mansouri","doi":"10.1051/radiopro/2024017","DOIUrl":null,"url":null,"abstract":"Accurate dose estimation in computed tomography (CT) scans is crucial and relies on precise normalization of output dose, typically measured by the volume CT dose index (CTDIvol). Key metrics, including effective diameter (Deff) and water-equivalent diameter (Dw), play pivotal roles in characterizing patient size. However, a notable gap exists in delineating the specific relationships between age and head patient size (Deff and Dw) for pediatric patients in Morocco. The primary objective of this study was to establish these critical associations between patient age and head patient size (Deff and Dw), providing a foundation for calculating size-specific dose estimates (SSDE) in pediatric head CT examinations. A retrospective analysis of data from 134 pediatric patients, aged 0-13 years, comprising 71 males and 63 females who underwent head CT scans, was conducted. Utilizing the Radiant DICOM Viewer, patient sizes were measured in terms of both lateral and anterior-posterior dimensions for Deff and Dw calculations based on CT images in DICOM format. Our analysis revealed robust correlations between patient size (Deff and Dw) and the patient's age, with R2 values ranging from 0.65 to 0.86. Notably, larger Dw values were consistently observed compared to Deff. For male patients, Deff measurements ranged from 9.02 to 18.77 cm, with Dw values spanning 9.83 to 20.16 cm. Female patients exhibited Deff values ranging from 8.77 to 17.41 cm and Dw values ranging from 8.92 to 18.37 cm. These findings shed light on the crucial relationship between age and patient size, facilitating more precise dose calculations.","PeriodicalId":21009,"journal":{"name":"Radioprotection","volume":null,"pages":null},"PeriodicalIF":1.4000,"publicationDate":"2024-05-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Characterizing Pediatric Head Patient Size in Moroccan Population: Establishing Age-Dependent Relationships for Accurate CT Dose Estimation\",\"authors\":\"H. Sekkat, K. Elmansouri, A. Khallouqi, A. Halimi, O. El rhazouani, Z. Tahiri, M. Talbi, M. El Mansouri\",\"doi\":\"10.1051/radiopro/2024017\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Accurate dose estimation in computed tomography (CT) scans is crucial and relies on precise normalization of output dose, typically measured by the volume CT dose index (CTDIvol). Key metrics, including effective diameter (Deff) and water-equivalent diameter (Dw), play pivotal roles in characterizing patient size. However, a notable gap exists in delineating the specific relationships between age and head patient size (Deff and Dw) for pediatric patients in Morocco. The primary objective of this study was to establish these critical associations between patient age and head patient size (Deff and Dw), providing a foundation for calculating size-specific dose estimates (SSDE) in pediatric head CT examinations. A retrospective analysis of data from 134 pediatric patients, aged 0-13 years, comprising 71 males and 63 females who underwent head CT scans, was conducted. Utilizing the Radiant DICOM Viewer, patient sizes were measured in terms of both lateral and anterior-posterior dimensions for Deff and Dw calculations based on CT images in DICOM format. Our analysis revealed robust correlations between patient size (Deff and Dw) and the patient's age, with R2 values ranging from 0.65 to 0.86. Notably, larger Dw values were consistently observed compared to Deff. For male patients, Deff measurements ranged from 9.02 to 18.77 cm, with Dw values spanning 9.83 to 20.16 cm. Female patients exhibited Deff values ranging from 8.77 to 17.41 cm and Dw values ranging from 8.92 to 18.37 cm. These findings shed light on the crucial relationship between age and patient size, facilitating more precise dose calculations.\",\"PeriodicalId\":21009,\"journal\":{\"name\":\"Radioprotection\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2024-05-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Radioprotection\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1051/radiopro/2024017\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENVIRONMENTAL SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radioprotection","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1051/radiopro/2024017","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENVIRONMENTAL SCIENCES","Score":null,"Total":0}
引用次数: 0

摘要

计算机断层扫描(CT)中精确的剂量估算至关重要,它依赖于输出剂量的精确归一化,通常以容积 CT 剂量指数(CTDIvol)来衡量。包括有效直径(Deff)和水当量直径(Dw)在内的关键指标在描述患者体型方面起着举足轻重的作用。然而,在界定摩洛哥儿科患者的年龄与头部患者体型(Deff 和 Dw)之间的具体关系方面存在明显差距。本研究的主要目的是确定患者年龄与头部患者体型(Deff 和 Dw)之间的关键关系,为计算儿科头部 CT 检查中的特定体型剂量估算值(SSDE)奠定基础。该研究对 134 名接受头部 CT 扫描的 0-13 岁儿科患者的数据进行了回顾性分析,其中包括 71 名男性和 63 名女性。利用 Radiant DICOM 查看器,根据 DICOM 格式的 CT 图像测量了患者的横向和前后尺寸,以计算 Deff 和 Dw。我们的分析表明,患者体型(Deff 和 Dw)与患者年龄之间存在很强的相关性,R2 值在 0.65 到 0.86 之间。值得注意的是,与 Deff 相比,Dw 值一直较大。男性患者的 Deff 测量值从 9.02 厘米到 18.77 厘米不等,Dw 值从 9.83 厘米到 20.16 厘米不等。女性患者的 Deff 值为 8.77 至 17.41 厘米,Dw 值为 8.92 至 18.37 厘米。这些发现揭示了年龄与患者体型之间的重要关系,有助于更精确地计算剂量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Characterizing Pediatric Head Patient Size in Moroccan Population: Establishing Age-Dependent Relationships for Accurate CT Dose Estimation
Accurate dose estimation in computed tomography (CT) scans is crucial and relies on precise normalization of output dose, typically measured by the volume CT dose index (CTDIvol). Key metrics, including effective diameter (Deff) and water-equivalent diameter (Dw), play pivotal roles in characterizing patient size. However, a notable gap exists in delineating the specific relationships between age and head patient size (Deff and Dw) for pediatric patients in Morocco. The primary objective of this study was to establish these critical associations between patient age and head patient size (Deff and Dw), providing a foundation for calculating size-specific dose estimates (SSDE) in pediatric head CT examinations. A retrospective analysis of data from 134 pediatric patients, aged 0-13 years, comprising 71 males and 63 females who underwent head CT scans, was conducted. Utilizing the Radiant DICOM Viewer, patient sizes were measured in terms of both lateral and anterior-posterior dimensions for Deff and Dw calculations based on CT images in DICOM format. Our analysis revealed robust correlations between patient size (Deff and Dw) and the patient's age, with R2 values ranging from 0.65 to 0.86. Notably, larger Dw values were consistently observed compared to Deff. For male patients, Deff measurements ranged from 9.02 to 18.77 cm, with Dw values spanning 9.83 to 20.16 cm. Female patients exhibited Deff values ranging from 8.77 to 17.41 cm and Dw values ranging from 8.92 to 18.37 cm. These findings shed light on the crucial relationship between age and patient size, facilitating more precise dose calculations.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Radioprotection
Radioprotection ENVIRONMENTAL SCIENCES-PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH
CiteScore
3.30
自引率
54.50%
发文量
35
审稿时长
>12 weeks
期刊介绍: Radioprotection publishes articles on all aspects of radiological protection, including non-ionising as well as ionising radiations. Fields of interest range from research, development and theory to operational matters, education and training. The very wide spectrum of its topics includes (theoretical and practical aspects): dosimetry, instrument development, specialized measuring techniques, epidemiology, biological effects (in vivo and in vitro) and risk and environmental impact assessments.
期刊最新文献
Young generations facing post-nuclear accident situations: from Chernobyl to Fukushima Le principe de limitation des doses et la tolérabilité du risque radiologique Evaluation of Barium sulfate-copper breast radiation shield for use in thoracic Computed Tomography Examinations Natural radioactivity and radiological hazards assessment in soil samples of Hassan district, Karnataka State, India Balancing precision and safety: the crucial imperative of radiation dose optimization in radiology and the role of certified medical physicists in quality assessment
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1