智能手表检测心脏瓣膜手术后患者心房颤动的有效性:一项前瞻性观察研究。

IF 1.2 4区 医学 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS Scandinavian Cardiovascular Journal Pub Date : 2024-12-01 Epub Date: 2024-05-25 DOI:10.1080/14017431.2024.2353069
Margrethe Müller, Tove Aminda Hanssen, David Johansen, Øyvind Jakobsen, John Erling Pedersen, Inger Lise Aamot Aksetøy, Trine Bernholdt Rasmussen, Gunnar Hartvigsen, Vegard Skogen, Gyrd Thrane
{"title":"智能手表检测心脏瓣膜手术后患者心房颤动的有效性:一项前瞻性观察研究。","authors":"Margrethe Müller, Tove Aminda Hanssen, David Johansen, Øyvind Jakobsen, John Erling Pedersen, Inger Lise Aamot Aksetøy, Trine Bernholdt Rasmussen, Gunnar Hartvigsen, Vegard Skogen, Gyrd Thrane","doi":"10.1080/14017431.2024.2353069","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Atrial fibrillation (AF) is a common early arrhythmia after heart valve surgery that limits physical activity. We aimed to evaluate the criterion validity of the Apple Watch Series 5 single-lead electrocardiogram (ECG) for detecting AF in patients after heart valve surgery.</p><p><strong>Design: </strong>We enrolled 105 patients from the University Hospital of North Norway, of whom 93 completed the study. All patients underwent single-lead ECG using the smartwatch three times or more daily on the second to third or third to fourth postoperative day. These results were compared with continuous 2-4 days ECG telemetry monitoring and a 12-lead ECG on the third postoperative day.</p><p><strong>Results: </strong>On comparing the Apple Watch ECGs with the ECG monitoring, the sensitivity and specificity to detect AF were 91% (75, 100) and 96% (91, 99), respectively. The accuracy was 95% (91, 99). On comparing Apple Watch ECG with a 12-lead ECG, the sensitivity was 71% (62, 100) and the specificity was 92% (92, 100).</p><p><strong>Conclusion: </strong>The Apple smartwatch single-lead ECG has high sensitivity and specificity, and might be a useful tool for detecting AF in patients after heart valve surgery.</p>","PeriodicalId":21383,"journal":{"name":"Scandinavian Cardiovascular Journal","volume":null,"pages":null},"PeriodicalIF":1.2000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Validity of a smartwatch for detecting atrial fibrillation in patients after heart valve surgery: a prospective observational study.\",\"authors\":\"Margrethe Müller, Tove Aminda Hanssen, David Johansen, Øyvind Jakobsen, John Erling Pedersen, Inger Lise Aamot Aksetøy, Trine Bernholdt Rasmussen, Gunnar Hartvigsen, Vegard Skogen, Gyrd Thrane\",\"doi\":\"10.1080/14017431.2024.2353069\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>Atrial fibrillation (AF) is a common early arrhythmia after heart valve surgery that limits physical activity. We aimed to evaluate the criterion validity of the Apple Watch Series 5 single-lead electrocardiogram (ECG) for detecting AF in patients after heart valve surgery.</p><p><strong>Design: </strong>We enrolled 105 patients from the University Hospital of North Norway, of whom 93 completed the study. All patients underwent single-lead ECG using the smartwatch three times or more daily on the second to third or third to fourth postoperative day. These results were compared with continuous 2-4 days ECG telemetry monitoring and a 12-lead ECG on the third postoperative day.</p><p><strong>Results: </strong>On comparing the Apple Watch ECGs with the ECG monitoring, the sensitivity and specificity to detect AF were 91% (75, 100) and 96% (91, 99), respectively. The accuracy was 95% (91, 99). On comparing Apple Watch ECG with a 12-lead ECG, the sensitivity was 71% (62, 100) and the specificity was 92% (92, 100).</p><p><strong>Conclusion: </strong>The Apple smartwatch single-lead ECG has high sensitivity and specificity, and might be a useful tool for detecting AF in patients after heart valve surgery.</p>\",\"PeriodicalId\":21383,\"journal\":{\"name\":\"Scandinavian Cardiovascular Journal\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2024-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Scandinavian Cardiovascular Journal\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1080/14017431.2024.2353069\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/5/25 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Scandinavian Cardiovascular Journal","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/14017431.2024.2353069","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/5/25 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

目的:心房颤动(AF)是心脏瓣膜手术后常见的早期心律失常,会限制体力活动。我们旨在评估 Apple Watch Series 5 单导联心电图(ECG)检测心脏瓣膜手术后患者房颤的标准有效性:我们从挪威北部大学医院招募了 105 名患者,其中 93 人完成了研究。所有患者在术后第二天至第三天或第三天至第四天每天三次或三次以上使用智能手表进行单导联心电图检查。这些结果与连续 2-4 天的心电图遥测监测和术后第三天的 12 导联心电图进行了比较:结果:将 Apple Watch 心电图与心电图监测进行比较,发现房颤的敏感性和特异性分别为 91% (75, 100) 和 96% (91, 99)。准确率为 95% (91, 99)。将 Apple Watch 心电图与 12 导联心电图进行比较,灵敏度为 71%(62, 100),特异性为 92%(92, 100):结论:苹果智能手表单导联心电图具有较高的灵敏度和特异性,可作为检测心脏瓣膜手术后患者房颤的有用工具。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Validity of a smartwatch for detecting atrial fibrillation in patients after heart valve surgery: a prospective observational study.

Objectives: Atrial fibrillation (AF) is a common early arrhythmia after heart valve surgery that limits physical activity. We aimed to evaluate the criterion validity of the Apple Watch Series 5 single-lead electrocardiogram (ECG) for detecting AF in patients after heart valve surgery.

Design: We enrolled 105 patients from the University Hospital of North Norway, of whom 93 completed the study. All patients underwent single-lead ECG using the smartwatch three times or more daily on the second to third or third to fourth postoperative day. These results were compared with continuous 2-4 days ECG telemetry monitoring and a 12-lead ECG on the third postoperative day.

Results: On comparing the Apple Watch ECGs with the ECG monitoring, the sensitivity and specificity to detect AF were 91% (75, 100) and 96% (91, 99), respectively. The accuracy was 95% (91, 99). On comparing Apple Watch ECG with a 12-lead ECG, the sensitivity was 71% (62, 100) and the specificity was 92% (92, 100).

Conclusion: The Apple smartwatch single-lead ECG has high sensitivity and specificity, and might be a useful tool for detecting AF in patients after heart valve surgery.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Scandinavian Cardiovascular Journal
Scandinavian Cardiovascular Journal 医学-心血管系统
CiteScore
3.40
自引率
0.00%
发文量
56
审稿时长
6-12 weeks
期刊介绍: The principal aim of Scandinavian Cardiovascular Journal is to promote cardiovascular research that crosses the borders between disciplines. The journal is a forum for the entire field of cardiovascular research, basic and clinical including: • Cardiology - Interventional and non-invasive • Cardiovascular epidemiology • Cardiovascular anaesthesia and intensive care • Cardiovascular surgery • Cardiovascular radiology • Clinical physiology • Transplantation of thoracic organs
期刊最新文献
Timing of Chest Tube Removal Following Adult Cardiac Surgery: A Cluster Randomized Controlled Trial. Self-rated health in primiparous women with congenital heart disease before, during and after pregnancy - A register study. Molecular mechanism of triptolide in myocardial fibrosis through the Wnt/β-catenin signaling pathway. Symptoms during pregnancy in primiparous women with congenital heart disease. PET evaluation of myocardial perfusion function after percutaneous coronary intervention in patients with chronic total occlusion: a systematic review and meta-analysis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1