使用锁定压缩板的近端螺钉固定技术用于马近端指间关节成形术的机械性能和失效模式:一项体内外研究。

IF 1 2区 农林科学 Q3 VETERINARY SCIENCES Veterinary and Comparative Orthopaedics and Traumatology Pub Date : 2024-11-01 Epub Date: 2024-06-04 DOI:10.1055/s-0044-1787680
Anderson F de Souza, César A M Pereira, Claudio Costa, Anton Fürst, Jan M Kümmerle, André L V De Zoppa
{"title":"使用锁定压缩板的近端螺钉固定技术用于马近端指间关节成形术的机械性能和失效模式:一项体内外研究。","authors":"Anderson F de Souza, César A M Pereira, Claudio Costa, Anton Fürst, Jan M Kümmerle, André L V De Zoppa","doi":"10.1055/s-0044-1787680","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong> The aim of this study was to measure the mechanical properties and failure mode of an <i>ex vivo</i> model of proximal interphalangeal arthrodesis in horses with different methods of proximal screw fixation using a locking compression plate.</p><p><strong>Study design: </strong> Pastern joint arthrodesis with a 3-hole 4.5-mm narrow locking compression plate was performed on 20 forelimbs of equine cadavers, randomized into four groups based on the fixation method and type of proximal screw used: unicortical cortex, bicortical cortex, unicortical locking, bicortical locking. Single-cycle axial compression testing was conducted until failure. The frequency of implant plastic deformation was recorded. Bone failure analysis was performed through computed tomography examinations and fractal analysis.</p><p><strong>Results: </strong> There were no differences in the analysed mechanical variables and fractal dimension among the groups. Transarticular screws showed a higher frequency of deformation (75%) regardless of the group. Both unicortical locking and bicortical locking groups deformed the plate more frequently.</p><p><strong>Conclusion: </strong> The type of screw used in the proximal hole of the locking compression plate and its method of anchoring in the proximal phalanx do not affect the mechanical properties of pastern arthrodesis in equine cadavers subjected to single-cycle axial compression tests until failure.</p>","PeriodicalId":51204,"journal":{"name":"Veterinary and Comparative Orthopaedics and Traumatology","volume":null,"pages":null},"PeriodicalIF":1.0000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Mechanical Properties and Failure Mode of Proximal Screw Fixation Technique Using Locking Compression Plate for Proximal Interphalangeal Arthrodesis in Horses: An Ex Vivo Study.\",\"authors\":\"Anderson F de Souza, César A M Pereira, Claudio Costa, Anton Fürst, Jan M Kümmerle, André L V De Zoppa\",\"doi\":\"10.1055/s-0044-1787680\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong> The aim of this study was to measure the mechanical properties and failure mode of an <i>ex vivo</i> model of proximal interphalangeal arthrodesis in horses with different methods of proximal screw fixation using a locking compression plate.</p><p><strong>Study design: </strong> Pastern joint arthrodesis with a 3-hole 4.5-mm narrow locking compression plate was performed on 20 forelimbs of equine cadavers, randomized into four groups based on the fixation method and type of proximal screw used: unicortical cortex, bicortical cortex, unicortical locking, bicortical locking. Single-cycle axial compression testing was conducted until failure. The frequency of implant plastic deformation was recorded. Bone failure analysis was performed through computed tomography examinations and fractal analysis.</p><p><strong>Results: </strong> There were no differences in the analysed mechanical variables and fractal dimension among the groups. Transarticular screws showed a higher frequency of deformation (75%) regardless of the group. Both unicortical locking and bicortical locking groups deformed the plate more frequently.</p><p><strong>Conclusion: </strong> The type of screw used in the proximal hole of the locking compression plate and its method of anchoring in the proximal phalanx do not affect the mechanical properties of pastern arthrodesis in equine cadavers subjected to single-cycle axial compression tests until failure.</p>\",\"PeriodicalId\":51204,\"journal\":{\"name\":\"Veterinary and Comparative Orthopaedics and Traumatology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2024-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Veterinary and Comparative Orthopaedics and Traumatology\",\"FirstCategoryId\":\"97\",\"ListUrlMain\":\"https://doi.org/10.1055/s-0044-1787680\",\"RegionNum\":2,\"RegionCategory\":\"农林科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/6/4 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"VETERINARY SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Veterinary and Comparative Orthopaedics and Traumatology","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.1055/s-0044-1787680","RegionNum":2,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/4 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

摘要

研究目的本研究的目的是测量使用锁定加压钢板的不同近端螺钉固定方法的马近端指间关节固定体外模型的机械性能和失效模式:研究设计:在20个马尸体前肢上使用3孔4.5毫米窄锁定加压板进行趾间关节固定术,根据固定方法和使用的近端螺钉类型随机分为四组:单皮质、双皮质、单皮质锁定、双皮质锁定。进行单循环轴向压缩测试,直至失效。记录种植体塑性变形的频率。通过计算机断层扫描检查和分形分析进行骨破坏分析:结果:各组在分析的机械变量和骨折尺寸方面没有差异。不同组别中,经关节螺钉的变形频率较高(75%)。单皮质锁定组和双皮质锁定组的钢板变形频率都更高:结论:锁定加压钢板近端孔中使用的螺钉类型及其在近端指骨中的锚定方法不会影响在马尸体上进行单循环轴向加压试验直至失效的趾骨关节固定术的机械性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Mechanical Properties and Failure Mode of Proximal Screw Fixation Technique Using Locking Compression Plate for Proximal Interphalangeal Arthrodesis in Horses: An Ex Vivo Study.

Objective:  The aim of this study was to measure the mechanical properties and failure mode of an ex vivo model of proximal interphalangeal arthrodesis in horses with different methods of proximal screw fixation using a locking compression plate.

Study design:  Pastern joint arthrodesis with a 3-hole 4.5-mm narrow locking compression plate was performed on 20 forelimbs of equine cadavers, randomized into four groups based on the fixation method and type of proximal screw used: unicortical cortex, bicortical cortex, unicortical locking, bicortical locking. Single-cycle axial compression testing was conducted until failure. The frequency of implant plastic deformation was recorded. Bone failure analysis was performed through computed tomography examinations and fractal analysis.

Results:  There were no differences in the analysed mechanical variables and fractal dimension among the groups. Transarticular screws showed a higher frequency of deformation (75%) regardless of the group. Both unicortical locking and bicortical locking groups deformed the plate more frequently.

Conclusion:  The type of screw used in the proximal hole of the locking compression plate and its method of anchoring in the proximal phalanx do not affect the mechanical properties of pastern arthrodesis in equine cadavers subjected to single-cycle axial compression tests until failure.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.00
自引率
15.40%
发文量
49
审稿时长
18-36 weeks
期刊介绍: Veterinary and Comparative Orthopaedics and Traumatology (VCOT) is the most important single source for clinically relevant information in orthopaedics and neurosurgery available anywhere in the world today. It is unique in that it is truly comparative and there is an unrivalled mix of review articles and basic science amid the information that is immediately clinically relevant in veterinary surgery today.
期刊最新文献
Revision of Hip Luxation in a Canine Total Hip Replacement Caused by a Greater Trochanteric Fracture Secondary to an Inflammatory Granuloma. Mechanical Properties and Failure Mode of Proximal Screw Fixation Technique Using Locking Compression Plate for Proximal Interphalangeal Arthrodesis in Horses: An Ex Vivo Study. Effect of Plate Inclination and Osteotomy Positioning on Rock-back following Tibial Plateau Levelling Osteotomy in Dogs. Spinal Neuronavigation for Lumbar Plate Fixation in Miniature Breed Dogs. Biomechanical Principles of Intramedullary Nails in Veterinary and Human Medicine.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1