{"title":"四种酶联免疫吸附试剂盒测量血清内皮素-1的准确性值得怀疑","authors":"Minqi Cai, Qian Zheng, Yiqiang Chen, Siyuan Liu, Huimin Zhu, Bing Bai","doi":"10.1515/labmed-2024-0028","DOIUrl":null,"url":null,"abstract":"Abstract Objectives Altered serum Netrin-1 levels have been widely reported in cancer and other clinical diseases and they are often measured by commercial ELISA kits. However, we found the questionable results using these kits and therefore performed this simple study to evaluate their accuracy in detection of serum Netrin-1. Methods Four commonly used commercial kits were collected. The kit standards were serially diluted or spiked into serum samples. The cells with confirmed expression of Netrin-1 and their culture medium, as well as the Netrin-1 controls of each kit were used for the kits to detect. The cell lysate samples and the kit controls were also blotted on a nitrocellulose membrane for detection antibodies of each kit to probe. Results Detection of the Netrin-1 standards in serum by each kit were all affected. Only one kit was able to detect Netrin-1 in the cell lysate or medium. No ELISA kits could detect all Netrin-1 controls of the four kits. None of the detection antibodies correctly probed Netrin-1 in the dot blot. Conclusions The accuracy of these four Netrin-1 ELISA kits is under question. Reported serum Netrin-1 levels based on measurements by these kits need be carefully interpreted.","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":"104 39","pages":""},"PeriodicalIF":17.7000,"publicationDate":"2024-06-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Questionable accuracy of four ELISA kits in serum Netrin-1 measurement\",\"authors\":\"Minqi Cai, Qian Zheng, Yiqiang Chen, Siyuan Liu, Huimin Zhu, Bing Bai\",\"doi\":\"10.1515/labmed-2024-0028\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract Objectives Altered serum Netrin-1 levels have been widely reported in cancer and other clinical diseases and they are often measured by commercial ELISA kits. However, we found the questionable results using these kits and therefore performed this simple study to evaluate their accuracy in detection of serum Netrin-1. Methods Four commonly used commercial kits were collected. The kit standards were serially diluted or spiked into serum samples. The cells with confirmed expression of Netrin-1 and their culture medium, as well as the Netrin-1 controls of each kit were used for the kits to detect. The cell lysate samples and the kit controls were also blotted on a nitrocellulose membrane for detection antibodies of each kit to probe. Results Detection of the Netrin-1 standards in serum by each kit were all affected. Only one kit was able to detect Netrin-1 in the cell lysate or medium. No ELISA kits could detect all Netrin-1 controls of the four kits. None of the detection antibodies correctly probed Netrin-1 in the dot blot. Conclusions The accuracy of these four Netrin-1 ELISA kits is under question. Reported serum Netrin-1 levels based on measurements by these kits need be carefully interpreted.\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":\"104 39\",\"pages\":\"\"},\"PeriodicalIF\":17.7000,\"publicationDate\":\"2024-06-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1515/labmed-2024-0028\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1515/labmed-2024-0028","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
Questionable accuracy of four ELISA kits in serum Netrin-1 measurement
Abstract Objectives Altered serum Netrin-1 levels have been widely reported in cancer and other clinical diseases and they are often measured by commercial ELISA kits. However, we found the questionable results using these kits and therefore performed this simple study to evaluate their accuracy in detection of serum Netrin-1. Methods Four commonly used commercial kits were collected. The kit standards were serially diluted or spiked into serum samples. The cells with confirmed expression of Netrin-1 and their culture medium, as well as the Netrin-1 controls of each kit were used for the kits to detect. The cell lysate samples and the kit controls were also blotted on a nitrocellulose membrane for detection antibodies of each kit to probe. Results Detection of the Netrin-1 standards in serum by each kit were all affected. Only one kit was able to detect Netrin-1 in the cell lysate or medium. No ELISA kits could detect all Netrin-1 controls of the four kits. None of the detection antibodies correctly probed Netrin-1 in the dot blot. Conclusions The accuracy of these four Netrin-1 ELISA kits is under question. Reported serum Netrin-1 levels based on measurements by these kits need be carefully interpreted.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.