USP 通过绝对法方法利用 SEC 多角光散射和折射率技术对商用聚(乳酸-共聚-乙醇酸)进行表征

Yixin Ren , Leo Liu , Yang Liu , Weidong Zhao , Peng Zhang , Hong Wang , Catherine Sheehan , Michael Ambrose
{"title":"USP 通过绝对法方法利用 SEC 多角光散射和折射率技术对商用聚(乳酸-共聚-乙醇酸)进行表征","authors":"Yixin Ren ,&nbsp;Leo Liu ,&nbsp;Yang Liu ,&nbsp;Weidong Zhao ,&nbsp;Peng Zhang ,&nbsp;Hong Wang ,&nbsp;Catherine Sheehan ,&nbsp;Michael Ambrose","doi":"10.1016/j.jpbao.2024.100031","DOIUrl":null,"url":null,"abstract":"<div><p>This research focuses on evaluating the data quality and reliability of Size Exclusion Chromatography with Multi-Angle Light Scattering and Refractive Index (SEC-MALS/RI) chromatography in determining molecular weight-related parameters in poly(lactic-co-glycolic) acid (PLGA) polymers. The study utilizes key metrics, particularly percent relative standard deviation (%RSD), to evaluate the precision across different data processing conditions. Exploring baseline selection of the chromatograms reveals that selection of the baseline based on the intrinsic shape of the chromatogram, rather than relying on elution peaks, improves consistency. The study emphasizes the critical role of result fitting in addressing systematic errors and sample heterogeneity, recommending the minima of the elution peak selection range for realistic molecular weight distribution representation. Analysis of light-scattering (LS) detector chromatograms highlights varying effects on different PLGA polymers, emphasizing the need for careful assessment and potential exclusion for precision improvement, especially in the presence of experimental artifacts. Across diverse PLGA polymers, the utilization of different column types, along with considerations such as baseline determination and peak selection, shows minimal variations in <em>M</em>n, <em>M</em>w, and polydispersity index (PDI), affirming the consistency of the methodology. The %RSD analysis further supports the methodology's precision, with values well within acceptable limits. In summary, this comprehensive evaluation of methodological conditions, including baseline selection, result fitting, LS detector data management, and column types, establishes a reliable SEC-MALS/RI chromatographic approach by Absolute Method for determining molecular weight parameters in PLGA polymers.</p></div>","PeriodicalId":100822,"journal":{"name":"Journal of Pharmaceutical and Biomedical Analysis Open","volume":"4 ","pages":"Article 100031"},"PeriodicalIF":0.0000,"publicationDate":"2024-06-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2949771X24000070/pdfft?md5=bbe1e901af41b24ff4f3540bad739844&pid=1-s2.0-S2949771X24000070-main.pdf","citationCount":"0","resultStr":"{\"title\":\"USP’s characterization of commercial poly(lactic-co-glycolic acid) utilizing SEC-Multi-Angle Light Scattering and Refractive Index techniques via Absolute Method approach\",\"authors\":\"Yixin Ren ,&nbsp;Leo Liu ,&nbsp;Yang Liu ,&nbsp;Weidong Zhao ,&nbsp;Peng Zhang ,&nbsp;Hong Wang ,&nbsp;Catherine Sheehan ,&nbsp;Michael Ambrose\",\"doi\":\"10.1016/j.jpbao.2024.100031\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>This research focuses on evaluating the data quality and reliability of Size Exclusion Chromatography with Multi-Angle Light Scattering and Refractive Index (SEC-MALS/RI) chromatography in determining molecular weight-related parameters in poly(lactic-co-glycolic) acid (PLGA) polymers. The study utilizes key metrics, particularly percent relative standard deviation (%RSD), to evaluate the precision across different data processing conditions. Exploring baseline selection of the chromatograms reveals that selection of the baseline based on the intrinsic shape of the chromatogram, rather than relying on elution peaks, improves consistency. The study emphasizes the critical role of result fitting in addressing systematic errors and sample heterogeneity, recommending the minima of the elution peak selection range for realistic molecular weight distribution representation. Analysis of light-scattering (LS) detector chromatograms highlights varying effects on different PLGA polymers, emphasizing the need for careful assessment and potential exclusion for precision improvement, especially in the presence of experimental artifacts. Across diverse PLGA polymers, the utilization of different column types, along with considerations such as baseline determination and peak selection, shows minimal variations in <em>M</em>n, <em>M</em>w, and polydispersity index (PDI), affirming the consistency of the methodology. The %RSD analysis further supports the methodology's precision, with values well within acceptable limits. In summary, this comprehensive evaluation of methodological conditions, including baseline selection, result fitting, LS detector data management, and column types, establishes a reliable SEC-MALS/RI chromatographic approach by Absolute Method for determining molecular weight parameters in PLGA polymers.</p></div>\",\"PeriodicalId\":100822,\"journal\":{\"name\":\"Journal of Pharmaceutical and Biomedical Analysis Open\",\"volume\":\"4 \",\"pages\":\"Article 100031\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-06-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S2949771X24000070/pdfft?md5=bbe1e901af41b24ff4f3540bad739844&pid=1-s2.0-S2949771X24000070-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Pharmaceutical and Biomedical Analysis Open\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2949771X24000070\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Pharmaceutical and Biomedical Analysis Open","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2949771X24000070","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

这项研究的重点是评估尺寸排阻色谱-多角度光散射和折射率(SEC-MALS/RI)色谱法在测定聚乳酸-共聚乙醇酸(PLGA)聚合物分子量相关参数时的数据质量和可靠性。研究利用关键指标,特别是相对标准偏差百分比 (%RSD) 来评估不同数据处理条件下的精度。对色谱基线选择的探索表明,根据色谱的固有形状选择基线,而不是依赖洗脱峰,可以提高一致性。研究强调了结果拟合在解决系统误差和样品异质性方面的关键作用,建议选择洗脱峰范围的最小值,以获得真实的分子量分布表示。对光散射(LS)检测器色谱图的分析凸显了对不同 PLGA 聚合物的不同影响,强调了仔细评估和排除潜在干扰以提高精度的必要性,尤其是在存在实验伪影的情况下。在不同的 PLGA 聚合物中,使用不同类型的色谱柱以及基线测定和峰值选择等注意事项显示,Mn、Mw 和多分散指数 (PDI) 的变化极小,从而肯定了该方法的一致性。%RSD分析进一步证明了该方法的精确性,其值完全在可接受的范围内。总之,通过对方法条件(包括基线选择、结果拟合、LS 检测器数据管理和色谱柱类型)的全面评估,采用绝对法确定 PLGA 聚合物分子量参数的 SEC-MALS/RI 色谱方法是可靠的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
USP’s characterization of commercial poly(lactic-co-glycolic acid) utilizing SEC-Multi-Angle Light Scattering and Refractive Index techniques via Absolute Method approach

This research focuses on evaluating the data quality and reliability of Size Exclusion Chromatography with Multi-Angle Light Scattering and Refractive Index (SEC-MALS/RI) chromatography in determining molecular weight-related parameters in poly(lactic-co-glycolic) acid (PLGA) polymers. The study utilizes key metrics, particularly percent relative standard deviation (%RSD), to evaluate the precision across different data processing conditions. Exploring baseline selection of the chromatograms reveals that selection of the baseline based on the intrinsic shape of the chromatogram, rather than relying on elution peaks, improves consistency. The study emphasizes the critical role of result fitting in addressing systematic errors and sample heterogeneity, recommending the minima of the elution peak selection range for realistic molecular weight distribution representation. Analysis of light-scattering (LS) detector chromatograms highlights varying effects on different PLGA polymers, emphasizing the need for careful assessment and potential exclusion for precision improvement, especially in the presence of experimental artifacts. Across diverse PLGA polymers, the utilization of different column types, along with considerations such as baseline determination and peak selection, shows minimal variations in Mn, Mw, and polydispersity index (PDI), affirming the consistency of the methodology. The %RSD analysis further supports the methodology's precision, with values well within acceptable limits. In summary, this comprehensive evaluation of methodological conditions, including baseline selection, result fitting, LS detector data management, and column types, establishes a reliable SEC-MALS/RI chromatographic approach by Absolute Method for determining molecular weight parameters in PLGA polymers.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Recent advances in molecular imprinting techniques for the electrochemical analysis of chiral compounds A review for cortisol sensing in medical applications Preparation of novel semi-covalent molecularly imprinted polymer for highly improved adsorption performance of tetracycline in aqueous medium Development and validation of LC/MS/MS quantification method for plantaricins in culture supernatant Fabrication of ultra-sensitive and disposable electrochemical biosensor: Detection of kidney injury molecule-1 protein in urine for diagnosis of kidney injury
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1