用于弱电网风光互补系统的并网型电压源逆变器

IF 5 Q1 ENGINEERING, ELECTRICAL & ELECTRONIC IEEE open journal of power electronics Pub Date : 2024-06-06 DOI:10.1109/OJPEL.2024.3410908
Amr Radwan;Mahmoud A. Elshenawy;Yasser Abdel-Rady I. Mohamed;Ehab Fahmy El-Saadany
{"title":"用于弱电网风光互补系统的并网型电压源逆变器","authors":"Amr Radwan;Mahmoud A. Elshenawy;Yasser Abdel-Rady I. Mohamed;Ehab Fahmy El-Saadany","doi":"10.1109/OJPEL.2024.3410908","DOIUrl":null,"url":null,"abstract":"This paper presents a grid-forming (GFM) voltage-source inverter (VSI) with direct current regulation for a hybrid wind-solar generator, enabling stable operation at very weak grid conditions and under faults. The GFM-VSI interfaces a hybrid wind-solar generator without an intermediate dc-dc conversion to increase the system efficiency. The wind generator comprises a wind turbine with a permanent magnet synchronous generator (PMSG) interfaced by a voltage-source rectifier (VSR). The PMSG-VSR and a solar photovoltaic (PV) array are connected to the GFM-VSI's dc-side. The VSR is responsible for extracting wind power with a power reserve option. The GFM-VSI is implemented to extract solar power with a power reserve capability and support the grid voltage or reactive power. The stable operation of the proposed system is validated under very weak grid conditions, and it is shown that a similar hybrid wind-solar system with grid-following control is unstable under the same weak grid conditions. A complete small-signal state-space model of the proposed hybrid system is developed and analyzed. Nonlinear time-domain simulations and real-time simulation tests verify the model's accuracy and show the proposed system's effective performance under challenging operating scenarios, such as grid uncertainties and faults.","PeriodicalId":93182,"journal":{"name":"IEEE open journal of power electronics","volume":null,"pages":null},"PeriodicalIF":5.0000,"publicationDate":"2024-06-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=10551428","citationCount":"0","resultStr":"{\"title\":\"Grid-Forming Voltage-Source Inverter for Hybrid Wind-Solar Systems Interfacing Weak Grids\",\"authors\":\"Amr Radwan;Mahmoud A. Elshenawy;Yasser Abdel-Rady I. Mohamed;Ehab Fahmy El-Saadany\",\"doi\":\"10.1109/OJPEL.2024.3410908\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a grid-forming (GFM) voltage-source inverter (VSI) with direct current regulation for a hybrid wind-solar generator, enabling stable operation at very weak grid conditions and under faults. The GFM-VSI interfaces a hybrid wind-solar generator without an intermediate dc-dc conversion to increase the system efficiency. The wind generator comprises a wind turbine with a permanent magnet synchronous generator (PMSG) interfaced by a voltage-source rectifier (VSR). The PMSG-VSR and a solar photovoltaic (PV) array are connected to the GFM-VSI's dc-side. The VSR is responsible for extracting wind power with a power reserve option. The GFM-VSI is implemented to extract solar power with a power reserve capability and support the grid voltage or reactive power. The stable operation of the proposed system is validated under very weak grid conditions, and it is shown that a similar hybrid wind-solar system with grid-following control is unstable under the same weak grid conditions. A complete small-signal state-space model of the proposed hybrid system is developed and analyzed. Nonlinear time-domain simulations and real-time simulation tests verify the model's accuracy and show the proposed system's effective performance under challenging operating scenarios, such as grid uncertainties and faults.\",\"PeriodicalId\":93182,\"journal\":{\"name\":\"IEEE open journal of power electronics\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":5.0000,\"publicationDate\":\"2024-06-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=10551428\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE open journal of power electronics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://ieeexplore.ieee.org/document/10551428/\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE open journal of power electronics","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/10551428/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

摘要

本文介绍了一种并网(GFM)电压源逆变器(VSI),该逆变器具有直流调节功能,适用于风能和太阳能混合发电机,可在电网非常薄弱的条件下和故障情况下稳定运行。GFM-VSI 与风能-太阳能混合发电机连接,无需中间的直流-直流转换,以提高系统效率。风力发电机由风力涡轮机和永磁同步发电机(PMSG)以及电压源整流器(VSR)组成。PMSG-VSR 和太阳能光伏 (PV) 阵列连接到 GFM-VSI 的直流侧。VSR 负责提取具有功率储备选项的风能。GFM-VSI 用于提取具有功率储备能力的太阳能电力,并支持电网电压或无功功率。在电网非常薄弱的条件下,验证了所提系统的稳定运行,并表明在同样薄弱的电网条件下,采用电网跟踪控制的类似风光互补系统是不稳定的。建立并分析了拟议混合系统的完整小信号状态空间模型。非线性时域仿真和实时仿真测试验证了模型的准确性,并显示了拟议系统在电网不确定性和故障等具有挑战性的运行情况下的有效性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Grid-Forming Voltage-Source Inverter for Hybrid Wind-Solar Systems Interfacing Weak Grids
This paper presents a grid-forming (GFM) voltage-source inverter (VSI) with direct current regulation for a hybrid wind-solar generator, enabling stable operation at very weak grid conditions and under faults. The GFM-VSI interfaces a hybrid wind-solar generator without an intermediate dc-dc conversion to increase the system efficiency. The wind generator comprises a wind turbine with a permanent magnet synchronous generator (PMSG) interfaced by a voltage-source rectifier (VSR). The PMSG-VSR and a solar photovoltaic (PV) array are connected to the GFM-VSI's dc-side. The VSR is responsible for extracting wind power with a power reserve option. The GFM-VSI is implemented to extract solar power with a power reserve capability and support the grid voltage or reactive power. The stable operation of the proposed system is validated under very weak grid conditions, and it is shown that a similar hybrid wind-solar system with grid-following control is unstable under the same weak grid conditions. A complete small-signal state-space model of the proposed hybrid system is developed and analyzed. Nonlinear time-domain simulations and real-time simulation tests verify the model's accuracy and show the proposed system's effective performance under challenging operating scenarios, such as grid uncertainties and faults.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
8.60
自引率
0.00%
发文量
0
审稿时长
8 weeks
期刊最新文献
Low Frequency versus High Frequency PWM in Medium Voltage, High Power, Higher Level Inverters: THD, Harmonic Filtering, and Efficiency Comparison Reliability Enhancement of Isolated Full-Bridge DC-DC Power Converter for Fast Charging of Electric Vehicles Constant-Parameter Average-Value Model of Power-Electronic Voltage-Source Converters With Direct Interface in Electromagnetic Transient Simulators A Novel Reduced-Order Modeling Approach of a Grid-Tied Hybrid Photovoltaic–Wind Turbine–Battery Energy Storage System for Dynamic Stability Analysis Ultra-High Gain Quadratic DC-DC Topology Using Two-winding Coupled Inductors with Voltage Multiplier Cells
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1