种植体螺钉通道内断裂螺钉的处理:病例报告

Q3 Dentistry Indian Journal of Dental Research Pub Date : 2024-01-01 Epub Date: 2024-06-20 DOI:10.4103/ijdr.ijdr_953_23
Sabrin Ali Azim, Hafsa Ali Aldrissi, Lovely M Annamma, Abdulhadi Warreth
{"title":"种植体螺钉通道内断裂螺钉的处理:病例报告","authors":"Sabrin Ali Azim, Hafsa Ali Aldrissi, Lovely M Annamma, Abdulhadi Warreth","doi":"10.4103/ijdr.ijdr_953_23","DOIUrl":null,"url":null,"abstract":"<p><strong>Rationale: </strong>This case report outlines a novel prosthodontic approach for managing a broken screw inside an implant screw channel, emphasising the importance of innovative solutions in implant dentistry.</p><p><strong>Patient concerns: </strong>A 57-year-old male patient sought restoration for implant-supported crowns (#46 and #47). A broken screw inside the implant screw channel posed a significant concern for both the patient and the dental team.</p><p><strong>Treatment: </strong>Utilising an impression pickup technique of the inner surface of the implant body, a custom titanium abutment was fabricated in the laboratory and restoration was successfully replaced. A follow-up of 6 months was performed, ensuring optimal function and patient satisfaction.</p><p><strong>Outcome: </strong>The custom titanium abutment with a zirconia crown was placed, leading to a successful restoration. The patient reported no discomfort, demonstrating improved function and aesthetics.</p><p><strong>Takeaway lesson: </strong>This case highlights the effectiveness of tailored prosthodontic interventions in addressing complex implant-related complications.</p>","PeriodicalId":13311,"journal":{"name":"Indian Journal of Dental Research","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Management of Broken Screw Inside Implant Screw Channel: A Case Report.\",\"authors\":\"Sabrin Ali Azim, Hafsa Ali Aldrissi, Lovely M Annamma, Abdulhadi Warreth\",\"doi\":\"10.4103/ijdr.ijdr_953_23\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Rationale: </strong>This case report outlines a novel prosthodontic approach for managing a broken screw inside an implant screw channel, emphasising the importance of innovative solutions in implant dentistry.</p><p><strong>Patient concerns: </strong>A 57-year-old male patient sought restoration for implant-supported crowns (#46 and #47). A broken screw inside the implant screw channel posed a significant concern for both the patient and the dental team.</p><p><strong>Treatment: </strong>Utilising an impression pickup technique of the inner surface of the implant body, a custom titanium abutment was fabricated in the laboratory and restoration was successfully replaced. A follow-up of 6 months was performed, ensuring optimal function and patient satisfaction.</p><p><strong>Outcome: </strong>The custom titanium abutment with a zirconia crown was placed, leading to a successful restoration. The patient reported no discomfort, demonstrating improved function and aesthetics.</p><p><strong>Takeaway lesson: </strong>This case highlights the effectiveness of tailored prosthodontic interventions in addressing complex implant-related complications.</p>\",\"PeriodicalId\":13311,\"journal\":{\"name\":\"Indian Journal of Dental Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Indian Journal of Dental Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/ijdr.ijdr_953_23\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/6/20 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"Dentistry\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indian Journal of Dental Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/ijdr.ijdr_953_23","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/20 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0

摘要

理由:本病例报告概述了一种处理种植体螺钉通道内断裂螺钉的新型修复方法,强调了创新解决方案在种植牙科中的重要性:一名 57 岁的男性患者寻求修复种植体支撑的牙冠(46 号和 47 号)。患者和牙科团队都非常担心种植体螺丝槽内的螺丝断裂问题:利用种植体内表面的印模采集技术,在技工室制作了一个定制的钛基台,并成功更换了修复体。进行了 6 个月的随访,确保了最佳功能和患者满意度:结果:定制的钛基台和氧化锆牙冠被植入,修复成功。患者表示没有任何不适感,功能和美观都得到了改善。启示: 本病例强调了量身定制的修复干预在解决复杂的种植相关并发症方面的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Management of Broken Screw Inside Implant Screw Channel: A Case Report.

Rationale: This case report outlines a novel prosthodontic approach for managing a broken screw inside an implant screw channel, emphasising the importance of innovative solutions in implant dentistry.

Patient concerns: A 57-year-old male patient sought restoration for implant-supported crowns (#46 and #47). A broken screw inside the implant screw channel posed a significant concern for both the patient and the dental team.

Treatment: Utilising an impression pickup technique of the inner surface of the implant body, a custom titanium abutment was fabricated in the laboratory and restoration was successfully replaced. A follow-up of 6 months was performed, ensuring optimal function and patient satisfaction.

Outcome: The custom titanium abutment with a zirconia crown was placed, leading to a successful restoration. The patient reported no discomfort, demonstrating improved function and aesthetics.

Takeaway lesson: This case highlights the effectiveness of tailored prosthodontic interventions in addressing complex implant-related complications.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Indian Journal of Dental Research
Indian Journal of Dental Research Dentistry-Dentistry (all)
CiteScore
1.80
自引率
0.00%
发文量
80
审稿时长
38 weeks
期刊介绍: Indian Journal of Dental Research (IJDR) is the official publication of the Indian Society for Dental Research (ISDR), India section of the International Association for Dental Research (IADR), published quarterly. IJDR publishes scientific papers on well designed and controlled original research involving orodental sciences. Papers may also include reports on unusual and interesting case presentations and invited review papers on significant topics.
期刊最新文献
Effect of Bisoctrizole on Ultraviolet (UV) Absorption Properties of Silicone and Effect on Surface Roughness - An In Vitro Study. Effect of Densah Burs on Primary and Secondary Stability of Immediately Loaded Implants in Addition to Crestal Bone Loss and Gingival Probing Depth - An Evaluative Study. Effect of Fluoride-releasing Resin Cement on the Development of White Spot Lesions Around Orthodontic Brackets - A Retrospective Study. Effect of Reduced-Step Polishing Systems on Color Stability of Nanocomposites Submitted to Thermocycling Staining with Common Beverages - An In Vitro Study. Evaluation of Stresses Generated with Two Different Self-Ligating Orthodontic Bracket Systems - A Finite Element Analysis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1