{"title":"利用液相色谱法/高分辨质谱法对马尿液中的 1000 多种化合物进行广谱、灵敏的筛选。","authors":"Taiga Uchida, Takaya Kisugi, Hideaki Ishii, Masayuki Yamada, Kenji Kinoshita, Gary Ngai-Wa Leung","doi":"10.1002/rcm.9856","DOIUrl":null,"url":null,"abstract":"<div>\n \n <section>\n \n <h3> Rationale</h3>\n \n <p>To uphold the integrity of horseracing and equestrian sports, it is critical for an equine doping control laboratory to develop a comprehensive screening method to cover a wide range of target substances at the required detection levels in equine urine.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>The procedure involved the enzymatic hydrolysis of 3 mL urine samples followed by solid-phase extraction using HF Bond Elut C18 cartridge. The resulting extracts were then separated on a C18 reversed-phase column and analyzed using liquid chromatography/high-resolution mass spectrometry (LC/HRMS) in both electrospray ionization positive and negative modes in two separate injections. The analytical data were obtained in full scan and product ion scan (PIS) modes in an 11 min LC run.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>The method can detect 1011 compounds (in both positive and negative ion modes). Over 95% of the target compounds have limits of detections (LODs) ≤10 ng/mL, and more than 50% of the LODs are ≤0.5 ng/mL. The lowest LOD can reach down to 0.01 ng/mL. The applicability of the method was demonstrated by the successful detection of prohibited substances in overseas and domestic equine urine samples.</p>\n </section>\n \n <section>\n \n <h3> Conclusions</h3>\n \n <p>We have successfully developed a regular screening method for equine urine samples that can detect more than 1000 compounds at sub-ppb levels in both positive and negative ion modes with full scan and PIS using LC/HRMS. Furthermore, this method can theoretically be expanded to accommodate an unlimited number of prohibited substances in full-scan mode.</p>\n </section>\n </div>","PeriodicalId":225,"journal":{"name":"Rapid Communications in Mass Spectrometry","volume":"38 17","pages":""},"PeriodicalIF":1.8000,"publicationDate":"2024-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Broad-spectrum and sensitive screening of more than 1000 compounds in equine urine using liquid chromatography/high-resolution mass spectrometry\",\"authors\":\"Taiga Uchida, Takaya Kisugi, Hideaki Ishii, Masayuki Yamada, Kenji Kinoshita, Gary Ngai-Wa Leung\",\"doi\":\"10.1002/rcm.9856\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n <section>\\n \\n <h3> Rationale</h3>\\n \\n <p>To uphold the integrity of horseracing and equestrian sports, it is critical for an equine doping control laboratory to develop a comprehensive screening method to cover a wide range of target substances at the required detection levels in equine urine.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Methods</h3>\\n \\n <p>The procedure involved the enzymatic hydrolysis of 3 mL urine samples followed by solid-phase extraction using HF Bond Elut C18 cartridge. The resulting extracts were then separated on a C18 reversed-phase column and analyzed using liquid chromatography/high-resolution mass spectrometry (LC/HRMS) in both electrospray ionization positive and negative modes in two separate injections. The analytical data were obtained in full scan and product ion scan (PIS) modes in an 11 min LC run.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Results</h3>\\n \\n <p>The method can detect 1011 compounds (in both positive and negative ion modes). Over 95% of the target compounds have limits of detections (LODs) ≤10 ng/mL, and more than 50% of the LODs are ≤0.5 ng/mL. The lowest LOD can reach down to 0.01 ng/mL. The applicability of the method was demonstrated by the successful detection of prohibited substances in overseas and domestic equine urine samples.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Conclusions</h3>\\n \\n <p>We have successfully developed a regular screening method for equine urine samples that can detect more than 1000 compounds at sub-ppb levels in both positive and negative ion modes with full scan and PIS using LC/HRMS. Furthermore, this method can theoretically be expanded to accommodate an unlimited number of prohibited substances in full-scan mode.</p>\\n </section>\\n </div>\",\"PeriodicalId\":225,\"journal\":{\"name\":\"Rapid Communications in Mass Spectrometry\",\"volume\":\"38 17\",\"pages\":\"\"},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2024-06-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Rapid Communications in Mass Spectrometry\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/rcm.9856\",\"RegionNum\":3,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"BIOCHEMICAL RESEARCH METHODS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Rapid Communications in Mass Spectrometry","FirstCategoryId":"92","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/rcm.9856","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
Broad-spectrum and sensitive screening of more than 1000 compounds in equine urine using liquid chromatography/high-resolution mass spectrometry
Rationale
To uphold the integrity of horseracing and equestrian sports, it is critical for an equine doping control laboratory to develop a comprehensive screening method to cover a wide range of target substances at the required detection levels in equine urine.
Methods
The procedure involved the enzymatic hydrolysis of 3 mL urine samples followed by solid-phase extraction using HF Bond Elut C18 cartridge. The resulting extracts were then separated on a C18 reversed-phase column and analyzed using liquid chromatography/high-resolution mass spectrometry (LC/HRMS) in both electrospray ionization positive and negative modes in two separate injections. The analytical data were obtained in full scan and product ion scan (PIS) modes in an 11 min LC run.
Results
The method can detect 1011 compounds (in both positive and negative ion modes). Over 95% of the target compounds have limits of detections (LODs) ≤10 ng/mL, and more than 50% of the LODs are ≤0.5 ng/mL. The lowest LOD can reach down to 0.01 ng/mL. The applicability of the method was demonstrated by the successful detection of prohibited substances in overseas and domestic equine urine samples.
Conclusions
We have successfully developed a regular screening method for equine urine samples that can detect more than 1000 compounds at sub-ppb levels in both positive and negative ion modes with full scan and PIS using LC/HRMS. Furthermore, this method can theoretically be expanded to accommodate an unlimited number of prohibited substances in full-scan mode.
期刊介绍:
Rapid Communications in Mass Spectrometry is a journal whose aim is the rapid publication of original research results and ideas on all aspects of the science of gas-phase ions; it covers all the associated scientific disciplines. There is no formal limit on paper length ("rapid" is not synonymous with "brief"), but papers should be of a length that is commensurate with the importance and complexity of the results being reported. Contributions may be theoretical or practical in nature; they may deal with methods, techniques and applications, or with the interpretation of results; they may cover any area in science that depends directly on measurements made upon gaseous ions or that is associated with such measurements.