Ismael Vera-Puerto, Shrabana Sarkar, Gianfranco Moris, Hugo Valdes, Marco Quiroz, Juan López, Francisco Encina, Pascal Molle, Carlos A. Arias
{"title":"首次报告垂直流人工湿地处理联合污水溢流时产生臭味的成分","authors":"Ismael Vera-Puerto, Shrabana Sarkar, Gianfranco Moris, Hugo Valdes, Marco Quiroz, Juan López, Francisco Encina, Pascal Molle, Carlos A. Arias","doi":"10.1039/d4ew00303a","DOIUrl":null,"url":null,"abstract":"The present study represents the first attempt to demonstrate the online monitoring of components responsible for odor sensation from a constructed wetland (CW) utilized in treating combined sewer overflow (CSO). An experimental CSO treatment plant located in the south of Chile, employing vertical flow (VF) CW, was monitored. The components responsible for odor generation—hydrogen sulphide (H2S), methyl mercaptens (CH3SH) ammonia (NH3) and volatile organic compounds (VOCs) — were tracked for 27 days. During the study, the VF CW underwent two operational phases with CSO loadings, each lasting four days. The findings reveal minimal generation of H2S, CH3SH and NH3 from the VF CW during the monitoring period, regardless of its operational status or the time of the day. However, VOCs exhibited different behavior. VOCs emerged as a potential contributor to odor sensation, with elevated levels observed during specific morning hours, which intensified when the VF CW was not operational. Nevertheless, the results suggest that the VF CW treatment has a limited impact on the production of gases responsible for odor sensation. This is complementary to previous studies focusing on water quality assessment, highlighting the potential of this technology for sustainable CSO treating.","PeriodicalId":75,"journal":{"name":"Environmental Science: Water Research & Technology","volume":null,"pages":null},"PeriodicalIF":3.5000,"publicationDate":"2024-07-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"First report of components responsible for odor sensation from a vertical flow constructed wetland treating combined sewer overflow\",\"authors\":\"Ismael Vera-Puerto, Shrabana Sarkar, Gianfranco Moris, Hugo Valdes, Marco Quiroz, Juan López, Francisco Encina, Pascal Molle, Carlos A. Arias\",\"doi\":\"10.1039/d4ew00303a\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The present study represents the first attempt to demonstrate the online monitoring of components responsible for odor sensation from a constructed wetland (CW) utilized in treating combined sewer overflow (CSO). An experimental CSO treatment plant located in the south of Chile, employing vertical flow (VF) CW, was monitored. The components responsible for odor generation—hydrogen sulphide (H2S), methyl mercaptens (CH3SH) ammonia (NH3) and volatile organic compounds (VOCs) — were tracked for 27 days. During the study, the VF CW underwent two operational phases with CSO loadings, each lasting four days. The findings reveal minimal generation of H2S, CH3SH and NH3 from the VF CW during the monitoring period, regardless of its operational status or the time of the day. However, VOCs exhibited different behavior. VOCs emerged as a potential contributor to odor sensation, with elevated levels observed during specific morning hours, which intensified when the VF CW was not operational. Nevertheless, the results suggest that the VF CW treatment has a limited impact on the production of gases responsible for odor sensation. This is complementary to previous studies focusing on water quality assessment, highlighting the potential of this technology for sustainable CSO treating.\",\"PeriodicalId\":75,\"journal\":{\"name\":\"Environmental Science: Water Research & Technology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.5000,\"publicationDate\":\"2024-07-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Environmental Science: Water Research & Technology\",\"FirstCategoryId\":\"93\",\"ListUrlMain\":\"https://doi.org/10.1039/d4ew00303a\",\"RegionNum\":4,\"RegionCategory\":\"环境科学与生态学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, ENVIRONMENTAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Environmental Science: Water Research & Technology","FirstCategoryId":"93","ListUrlMain":"https://doi.org/10.1039/d4ew00303a","RegionNum":4,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, ENVIRONMENTAL","Score":null,"Total":0}
First report of components responsible for odor sensation from a vertical flow constructed wetland treating combined sewer overflow
The present study represents the first attempt to demonstrate the online monitoring of components responsible for odor sensation from a constructed wetland (CW) utilized in treating combined sewer overflow (CSO). An experimental CSO treatment plant located in the south of Chile, employing vertical flow (VF) CW, was monitored. The components responsible for odor generation—hydrogen sulphide (H2S), methyl mercaptens (CH3SH) ammonia (NH3) and volatile organic compounds (VOCs) — were tracked for 27 days. During the study, the VF CW underwent two operational phases with CSO loadings, each lasting four days. The findings reveal minimal generation of H2S, CH3SH and NH3 from the VF CW during the monitoring period, regardless of its operational status or the time of the day. However, VOCs exhibited different behavior. VOCs emerged as a potential contributor to odor sensation, with elevated levels observed during specific morning hours, which intensified when the VF CW was not operational. Nevertheless, the results suggest that the VF CW treatment has a limited impact on the production of gases responsible for odor sensation. This is complementary to previous studies focusing on water quality assessment, highlighting the potential of this technology for sustainable CSO treating.
期刊介绍:
Environmental Science: Water Research & Technology seeks to showcase high quality research about fundamental science, innovative technologies, and management practices that promote sustainable water.