视觉皮质厚度随长时间人工视觉恢复而增加

Noelle Stiles, Jeiran Choupan, Hossein Ameri, Vivek Patel, Yonggang Shi
{"title":"视觉皮质厚度随长时间人工视觉恢复而增加","authors":"Noelle Stiles, Jeiran Choupan, Hossein Ameri, Vivek Patel, Yonggang Shi","doi":"10.1101/2024.06.26.24309493","DOIUrl":null,"url":null,"abstract":"The Argus II retinal prosthesis restores visual perception to late blind patients. It has been shown that structural changes occur in the brain due to late-onset blindness, including cortical thinning in visual regions of the brain. Following vision restoration, it is not yet known whether these visual regions are reinvigorated and regain a normal cortical thickness or retain the diminished thickness from blindness.\nWe evaluated the cortical thicknesses of ten Argus II Retinal Prostheses patients, ten blind patients, and thirteen sighted participants. The Argus II patients on average had a thicker left Cuneus Cortex and Lateral Occipital Cortex relative to the blind patients. The duration of the Argus II use (time since implant in active users) significantly partially correlated with thicker visual cortical regions in the left hemisphere. Furthermore, in the two case studies (scanned before and after implantation), the patient with longer device use (44.5 months) had an increase in the cortical thickness of visual regions, whereas the shorter-using patient did not (6.5 months). Finally, a third case, scanned at three time points post-implantation, showed an increase in cortical thickness in the Lateral Occipital Cortex between 43.5 and 57 months, which was maintained even after 3 years of disuse (106 months).\nOverall, the Argus II patients cortical thickness was on average significantly rejuvenated in two higher visual regions and, patients using the implant for a longer duration had thicker visual regions. This research raises the possibility of structural plasticity reversing visual cortical atrophy in late-blind patients with prolonged vision restoration.","PeriodicalId":501390,"journal":{"name":"medRxiv - Ophthalmology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-06-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Visual Cortical Thickness Increases with Prolonged Artificial Vision Restoration\",\"authors\":\"Noelle Stiles, Jeiran Choupan, Hossein Ameri, Vivek Patel, Yonggang Shi\",\"doi\":\"10.1101/2024.06.26.24309493\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The Argus II retinal prosthesis restores visual perception to late blind patients. It has been shown that structural changes occur in the brain due to late-onset blindness, including cortical thinning in visual regions of the brain. Following vision restoration, it is not yet known whether these visual regions are reinvigorated and regain a normal cortical thickness or retain the diminished thickness from blindness.\\nWe evaluated the cortical thicknesses of ten Argus II Retinal Prostheses patients, ten blind patients, and thirteen sighted participants. The Argus II patients on average had a thicker left Cuneus Cortex and Lateral Occipital Cortex relative to the blind patients. The duration of the Argus II use (time since implant in active users) significantly partially correlated with thicker visual cortical regions in the left hemisphere. Furthermore, in the two case studies (scanned before and after implantation), the patient with longer device use (44.5 months) had an increase in the cortical thickness of visual regions, whereas the shorter-using patient did not (6.5 months). Finally, a third case, scanned at three time points post-implantation, showed an increase in cortical thickness in the Lateral Occipital Cortex between 43.5 and 57 months, which was maintained even after 3 years of disuse (106 months).\\nOverall, the Argus II patients cortical thickness was on average significantly rejuvenated in two higher visual regions and, patients using the implant for a longer duration had thicker visual regions. This research raises the possibility of structural plasticity reversing visual cortical atrophy in late-blind patients with prolonged vision restoration.\",\"PeriodicalId\":501390,\"journal\":{\"name\":\"medRxiv - Ophthalmology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-06-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"medRxiv - Ophthalmology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1101/2024.06.26.24309493\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"medRxiv - Ophthalmology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1101/2024.06.26.24309493","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

Argus II 视网膜假体能让晚期失明患者恢复视觉感知。研究表明,晚期失明会导致大脑结构发生变化,包括大脑视觉区域的皮质变薄。我们评估了十名 Argus II 视网膜假体患者、十名盲人患者和十三名视力正常者的大脑皮层厚度。与失明患者相比,Argus II 患者的左侧楔皮层和枕叶外侧皮层平均较厚。使用 Argus II 的持续时间(积极使用者的植入时间)与左半球视觉皮层区域的厚度有明显的部分相关性。此外,在两个病例研究(植入前后扫描)中,使用设备时间较长(44.5 个月)的患者视觉区域皮质厚度有所增加,而使用时间较短的患者(6.5 个月)则没有增加。最后,第三个病例在植入后的三个时间点进行了扫描,结果显示,在 43.5 个月至 57 个月期间,枕叶外侧皮层厚度有所增加,即使在停用 3 年(106 个月)后仍能保持。这项研究提出了结构可塑性逆转视力恢复期较长的晚盲患者视觉皮质萎缩的可能性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Visual Cortical Thickness Increases with Prolonged Artificial Vision Restoration
The Argus II retinal prosthesis restores visual perception to late blind patients. It has been shown that structural changes occur in the brain due to late-onset blindness, including cortical thinning in visual regions of the brain. Following vision restoration, it is not yet known whether these visual regions are reinvigorated and regain a normal cortical thickness or retain the diminished thickness from blindness. We evaluated the cortical thicknesses of ten Argus II Retinal Prostheses patients, ten blind patients, and thirteen sighted participants. The Argus II patients on average had a thicker left Cuneus Cortex and Lateral Occipital Cortex relative to the blind patients. The duration of the Argus II use (time since implant in active users) significantly partially correlated with thicker visual cortical regions in the left hemisphere. Furthermore, in the two case studies (scanned before and after implantation), the patient with longer device use (44.5 months) had an increase in the cortical thickness of visual regions, whereas the shorter-using patient did not (6.5 months). Finally, a third case, scanned at three time points post-implantation, showed an increase in cortical thickness in the Lateral Occipital Cortex between 43.5 and 57 months, which was maintained even after 3 years of disuse (106 months). Overall, the Argus II patients cortical thickness was on average significantly rejuvenated in two higher visual regions and, patients using the implant for a longer duration had thicker visual regions. This research raises the possibility of structural plasticity reversing visual cortical atrophy in late-blind patients with prolonged vision restoration.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Prediction of the ectasia screening index from raw Casia2 volume data for keratoconus identification by using convolutional neural networks Utilizing AI-Generated Plain Language Summaries to Enhance Interdisciplinary Understanding of Ophthalmology Notes: A Randomized Trial Deep Learning-Based Detection of Reticular Pseudodrusen in Age-Related Macular Degeneration on Optical Coherence Tomography Photoreceptor outer segment reflectivity with ultrahigh resolution visible light optical coherence tomography in systemic hydroxychloroquine use Comparison of visual function analysis of people with low vision using three different models of augmented reality devices
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1