IF 3.5 2区 工程技术 Q3 ENERGY & FUELS Geothermics Pub Date : 2024-07-16 DOI:10.1016/j.geothermics.2024.103080
{"title":"立式和模块式地源热泵系统的碳排放比较评估","authors":"","doi":"10.1016/j.geothermics.2024.103080","DOIUrl":null,"url":null,"abstract":"<div><p>The urgent need to address climate change necessitates a reduction in carbon emissions, particularly within the building sector. To achieve carbon neutrality, innovative technologies such as carbon capture, renewable energy systems, and carbon-neutral materials have been developed. However, there remains a dearth of research quantitatively analyzing carbon emissions through a life cycle assessment while implementing these technologies in real-world building scenarios. Additionally, Ground-source Heat Pumps (GSHPs) demonstrate superior efficiency compared to Air-source Heat Pumps (ASHPs) by leveraging stable ground temperatures, yet their widespread adoption is hindered by high initial investment costs. This study compares and analyzes the carbon emissions of GSHPs with Modular Ground Heat Exchangers (MGHXs), designed to mitigate initial investment barriers, alongside Vertical Ground Heat Exchangers (VGHXs) and ASHPs. The primary objective is to evaluate technology adoption feasibility from a carbon equivalent perspective, focusing on energy demand through building energy simulation. Results indicate that MGHXs exhibit a 6.7 % reduction in carbon emissions compared to VGHXs during production and construction (stage A). However, MGHXs generate 0.57 CO2-eq more per square meter per year during building operation (stage C). The implementation of geothermal energy systems in new buildings across South Korea could potentially achieve a maximum reduction effect of 11.6 % concerning the country's NDC (Nationally Determined Contributions) 2030 carbon reduction target.</p></div>","PeriodicalId":55095,"journal":{"name":"Geothermics","volume":null,"pages":null},"PeriodicalIF":3.5000,"publicationDate":"2024-07-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparative carbon emission assessment of vertical and modular ground source heat pump systems\",\"authors\":\"\",\"doi\":\"10.1016/j.geothermics.2024.103080\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>The urgent need to address climate change necessitates a reduction in carbon emissions, particularly within the building sector. To achieve carbon neutrality, innovative technologies such as carbon capture, renewable energy systems, and carbon-neutral materials have been developed. However, there remains a dearth of research quantitatively analyzing carbon emissions through a life cycle assessment while implementing these technologies in real-world building scenarios. Additionally, Ground-source Heat Pumps (GSHPs) demonstrate superior efficiency compared to Air-source Heat Pumps (ASHPs) by leveraging stable ground temperatures, yet their widespread adoption is hindered by high initial investment costs. This study compares and analyzes the carbon emissions of GSHPs with Modular Ground Heat Exchangers (MGHXs), designed to mitigate initial investment barriers, alongside Vertical Ground Heat Exchangers (VGHXs) and ASHPs. The primary objective is to evaluate technology adoption feasibility from a carbon equivalent perspective, focusing on energy demand through building energy simulation. Results indicate that MGHXs exhibit a 6.7 % reduction in carbon emissions compared to VGHXs during production and construction (stage A). However, MGHXs generate 0.57 CO2-eq more per square meter per year during building operation (stage C). The implementation of geothermal energy systems in new buildings across South Korea could potentially achieve a maximum reduction effect of 11.6 % concerning the country's NDC (Nationally Determined Contributions) 2030 carbon reduction target.</p></div>\",\"PeriodicalId\":55095,\"journal\":{\"name\":\"Geothermics\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.5000,\"publicationDate\":\"2024-07-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Geothermics\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S037565052400169X\",\"RegionNum\":2,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENERGY & FUELS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Geothermics","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S037565052400169X","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
引用次数: 0

摘要

应对气候变化的迫切需要要求减少碳排放,尤其是在建筑领域。为了实现碳中和,碳捕获、可再生能源系统和碳中和材料等创新技术已被开发出来。然而,通过生命周期评估对碳排放进行定量分析,同时在现实世界的建筑场景中实施这些技术的研究仍然十分匮乏。此外,与空气源热泵(ASHPs)相比,地源热泵(GSHPs)通过利用稳定的地温显示出更高的效率,但其广泛采用却受到高昂的初始投资成本的阻碍。本研究比较和分析了 GSHPs 与模块化地热交换器 (MGHXs) 的碳排放情况,MGHXs 的设计目的是减少初期投资障碍,同时还比较和分析了垂直地热交换器 (VGHXs) 和 ASHPs 的碳排放情况。主要目的是从碳当量的角度评估技术采用的可行性,重点是通过建筑能源模拟来评估能源需求。结果表明,在生产和施工阶段(A 阶段),MGHX 的碳排放量比 VGHX 减少了 6.7%。然而,在建筑运行期间(C阶段),MGHX每年每平方米多产生0.57二氧化碳当量。在韩国各地的新建建筑中采用地热能源系统,有可能实现最大 11.6% 的减排效果,达到该国 2030 年的 NDC(国家确定的贡献)碳减排目标。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Comparative carbon emission assessment of vertical and modular ground source heat pump systems

The urgent need to address climate change necessitates a reduction in carbon emissions, particularly within the building sector. To achieve carbon neutrality, innovative technologies such as carbon capture, renewable energy systems, and carbon-neutral materials have been developed. However, there remains a dearth of research quantitatively analyzing carbon emissions through a life cycle assessment while implementing these technologies in real-world building scenarios. Additionally, Ground-source Heat Pumps (GSHPs) demonstrate superior efficiency compared to Air-source Heat Pumps (ASHPs) by leveraging stable ground temperatures, yet their widespread adoption is hindered by high initial investment costs. This study compares and analyzes the carbon emissions of GSHPs with Modular Ground Heat Exchangers (MGHXs), designed to mitigate initial investment barriers, alongside Vertical Ground Heat Exchangers (VGHXs) and ASHPs. The primary objective is to evaluate technology adoption feasibility from a carbon equivalent perspective, focusing on energy demand through building energy simulation. Results indicate that MGHXs exhibit a 6.7 % reduction in carbon emissions compared to VGHXs during production and construction (stage A). However, MGHXs generate 0.57 CO2-eq more per square meter per year during building operation (stage C). The implementation of geothermal energy systems in new buildings across South Korea could potentially achieve a maximum reduction effect of 11.6 % concerning the country's NDC (Nationally Determined Contributions) 2030 carbon reduction target.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Geothermics
Geothermics 工程技术-地球科学综合
CiteScore
7.70
自引率
15.40%
发文量
237
审稿时长
4.5 months
期刊介绍: Geothermics is an international journal devoted to the research and development of geothermal energy. The International Board of Editors of Geothermics, which comprises specialists in the various aspects of geothermal resources, exploration and development, guarantees the balanced, comprehensive view of scientific and technological developments in this promising energy field. It promulgates the state of the art and science of geothermal energy, its exploration and exploitation through a regular exchange of information from all parts of the world. The journal publishes articles dealing with the theory, exploration techniques and all aspects of the utilization of geothermal resources. Geothermics serves as the scientific house, or exchange medium, through which the growing community of geothermal specialists can provide and receive information.
期刊最新文献
Numerical investigation of the geometric parameters effect of helical blades installed on horizontal geo heat exchanger A segmented analytical solution heat transfer model of U-tube ground heat exchanger based on finite solid cylindrical heat source method Geothermal distribution and evolution of fault-controlled Linyi geothermal system: Constrained from hydrogeochemical composition and numerical simulation Structural controls on hydrothermal fluid flow in a carbonate geothermal reservoir: Insights from giant carbonate veins in western Germany Experiences as heuristics for geothermal public perception: Testing the correlation between thermal waters recreation and geothermal energy perception
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1