{"title":"仪器中子活化分析直接比较标准化方法综合测量方程的开发与应用","authors":"Giancarlo D'Agostino, Marco Di Luzio","doi":"10.1016/j.sab.2024.106997","DOIUrl":null,"url":null,"abstract":"<div><p>A comprehensive model equation for the measurement of elemental mass fractions in solid materials using the direct standardization method of Instrumental Neutron Activation Analysis was developed. The extensive modelling established for the single comparator standardization was revised and changed for the direct standardization to obtain a complete mathematical description of the measurand by physical and chemical quantities having dimensions in SI units. The model equation is presented both in case measurement and standard samples are measured in the same γ-counting position and in different γ-counting positions. The first was successfully applied for the quantitative determination of As mass fraction in a seafood matrix with a percent level relative uncertainty. The SI traceability of the result is established by a traceable standard via the measurement equation and the uncertainty budget compiled to highlight the input quantities that contribute most to the combined uncertainty.</p></div>","PeriodicalId":21890,"journal":{"name":"Spectrochimica Acta Part B: Atomic Spectroscopy","volume":"218 ","pages":"Article 106997"},"PeriodicalIF":3.2000,"publicationDate":"2024-07-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S0584854724001411/pdfft?md5=90e4ee12831c27c10e1375270438cb6c&pid=1-s2.0-S0584854724001411-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Development and application of a comprehensive measurement equation for the direct comparator standardization method of Instrumental Neutron Activation Analysis\",\"authors\":\"Giancarlo D'Agostino, Marco Di Luzio\",\"doi\":\"10.1016/j.sab.2024.106997\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>A comprehensive model equation for the measurement of elemental mass fractions in solid materials using the direct standardization method of Instrumental Neutron Activation Analysis was developed. The extensive modelling established for the single comparator standardization was revised and changed for the direct standardization to obtain a complete mathematical description of the measurand by physical and chemical quantities having dimensions in SI units. The model equation is presented both in case measurement and standard samples are measured in the same γ-counting position and in different γ-counting positions. The first was successfully applied for the quantitative determination of As mass fraction in a seafood matrix with a percent level relative uncertainty. The SI traceability of the result is established by a traceable standard via the measurement equation and the uncertainty budget compiled to highlight the input quantities that contribute most to the combined uncertainty.</p></div>\",\"PeriodicalId\":21890,\"journal\":{\"name\":\"Spectrochimica Acta Part B: Atomic Spectroscopy\",\"volume\":\"218 \",\"pages\":\"Article 106997\"},\"PeriodicalIF\":3.2000,\"publicationDate\":\"2024-07-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S0584854724001411/pdfft?md5=90e4ee12831c27c10e1375270438cb6c&pid=1-s2.0-S0584854724001411-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Spectrochimica Acta Part B: Atomic Spectroscopy\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0584854724001411\",\"RegionNum\":2,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"SPECTROSCOPY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Spectrochimica Acta Part B: Atomic Spectroscopy","FirstCategoryId":"92","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0584854724001411","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"SPECTROSCOPY","Score":null,"Total":0}
引用次数: 0
摘要
利用仪器中子活化分析直接标准化方法,建立了测量固体材料中元素质量分数的综合模型方程。针对直接标准化方法,对为单个比较器标准化方法建立的大量模型进行了修订和修改,以获得以国际单位制(SI)为单位的物理量和化学量对测量值的完整数学描述。在测量和标准样品在相同的 γ 计数位置和不同的 γ 计数位置测量的情况下,都给出了模型方程。第一种方法成功应用于海产品基质中砷质量分数的定量测定,相对不确定度为百分数。结果的 SI 可追溯性是通过测量方程和不确定度预算编制的可追溯标准确定的,以突出对综合不确定度影响最大的输入量。
Development and application of a comprehensive measurement equation for the direct comparator standardization method of Instrumental Neutron Activation Analysis
A comprehensive model equation for the measurement of elemental mass fractions in solid materials using the direct standardization method of Instrumental Neutron Activation Analysis was developed. The extensive modelling established for the single comparator standardization was revised and changed for the direct standardization to obtain a complete mathematical description of the measurand by physical and chemical quantities having dimensions in SI units. The model equation is presented both in case measurement and standard samples are measured in the same γ-counting position and in different γ-counting positions. The first was successfully applied for the quantitative determination of As mass fraction in a seafood matrix with a percent level relative uncertainty. The SI traceability of the result is established by a traceable standard via the measurement equation and the uncertainty budget compiled to highlight the input quantities that contribute most to the combined uncertainty.
期刊介绍:
Spectrochimica Acta Part B: Atomic Spectroscopy, is intended for the rapid publication of both original work and reviews in the following fields:
Atomic Emission (AES), Atomic Absorption (AAS) and Atomic Fluorescence (AFS) spectroscopy;
Mass Spectrometry (MS) for inorganic analysis covering Spark Source (SS-MS), Inductively Coupled Plasma (ICP-MS), Glow Discharge (GD-MS), and Secondary Ion Mass Spectrometry (SIMS).
Laser induced atomic spectroscopy for inorganic analysis, including non-linear optical laser spectroscopy, covering Laser Enhanced Ionization (LEI), Laser Induced Fluorescence (LIF), Resonance Ionization Spectroscopy (RIS) and Resonance Ionization Mass Spectrometry (RIMS); Laser Induced Breakdown Spectroscopy (LIBS); Cavity Ringdown Spectroscopy (CRDS), Laser Ablation Inductively Coupled Plasma Atomic Emission Spectroscopy (LA-ICP-AES) and Laser Ablation Inductively Coupled Plasma Mass Spectrometry (LA-ICP-MS).
X-ray spectrometry, X-ray Optics and Microanalysis, including X-ray fluorescence spectrometry (XRF) and related techniques, in particular Total-reflection X-ray Fluorescence Spectrometry (TXRF), and Synchrotron Radiation-excited Total reflection XRF (SR-TXRF).
Manuscripts dealing with (i) fundamentals, (ii) methodology development, (iii)instrumentation, and (iv) applications, can be submitted for publication.