Luciana Silva Colepícolo, Maria Auxiliadora Mourão Martinez, Andrea Augusto Rodrigues, Leonardo Silveira Baeta, Fernando Oliveira Costa
{"title":"创新的双基台或三基台种植体:为期 3-12 年的病例研究。","authors":"Luciana Silva Colepícolo, Maria Auxiliadora Mourão Martinez, Andrea Augusto Rodrigues, Leonardo Silveira Baeta, Fernando Oliveira Costa","doi":"10.1002/cap.10300","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The aim of this case study is to present the rationality and scientific evidence of a new design for a double (DA) and triple (TA) dental abutment-implant with their specific new concept of biodynamic optimized peri-implant tissue (BOPiT).</p><p><strong>Methods: </strong>The innovative design of these abutments with a paraboloid geometry was based on BOPiT, simultaneously involving the principles of mechanobiology, biotensegrity, and mechanotransduction. Thus, 37 consecutive individuals/43 cases rehabilitated with single dental implant using the innovative DA (n = 28) and TA (n = 15) on 43 implants were included in this case study. The DA and TA support 2 or 3 dental crowns on a single implant, respectively. Clinic and radiographic examinations were presented at T1 (loading after 4 months) and T2 [final examination with an average follow-up time of 7.2 years (>3 to 12 years)].</p><p><strong>Results: </strong>At T2, mean scores for plaque index, peri-implant bleeding on probing, and peri-implant probing depth were low, depicting healthy peri-implant conditions. All radiographic images showed insignificant annual marginal bone loss (0.022 ± 0.05 mm) when compared to T1, reflecting great bone stability.</p><p><strong>Conclusion: </strong>DA and TA, based on the BOPiT concept, represent an advantageous, simple and non-invasive mechanism for the longevity and healthy regulation of the peri-implant tissues.</p>","PeriodicalId":55950,"journal":{"name":"Clinical Advances in Periodontics","volume":null,"pages":null},"PeriodicalIF":0.9000,"publicationDate":"2024-07-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The innovative double or triple dental abutment-implant: Case study with a 3-to-12-year follow-up.\",\"authors\":\"Luciana Silva Colepícolo, Maria Auxiliadora Mourão Martinez, Andrea Augusto Rodrigues, Leonardo Silveira Baeta, Fernando Oliveira Costa\",\"doi\":\"10.1002/cap.10300\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>The aim of this case study is to present the rationality and scientific evidence of a new design for a double (DA) and triple (TA) dental abutment-implant with their specific new concept of biodynamic optimized peri-implant tissue (BOPiT).</p><p><strong>Methods: </strong>The innovative design of these abutments with a paraboloid geometry was based on BOPiT, simultaneously involving the principles of mechanobiology, biotensegrity, and mechanotransduction. Thus, 37 consecutive individuals/43 cases rehabilitated with single dental implant using the innovative DA (n = 28) and TA (n = 15) on 43 implants were included in this case study. The DA and TA support 2 or 3 dental crowns on a single implant, respectively. Clinic and radiographic examinations were presented at T1 (loading after 4 months) and T2 [final examination with an average follow-up time of 7.2 years (>3 to 12 years)].</p><p><strong>Results: </strong>At T2, mean scores for plaque index, peri-implant bleeding on probing, and peri-implant probing depth were low, depicting healthy peri-implant conditions. All radiographic images showed insignificant annual marginal bone loss (0.022 ± 0.05 mm) when compared to T1, reflecting great bone stability.</p><p><strong>Conclusion: </strong>DA and TA, based on the BOPiT concept, represent an advantageous, simple and non-invasive mechanism for the longevity and healthy regulation of the peri-implant tissues.</p>\",\"PeriodicalId\":55950,\"journal\":{\"name\":\"Clinical Advances in Periodontics\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.9000,\"publicationDate\":\"2024-07-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical Advances in Periodontics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1002/cap.10300\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Advances in Periodontics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/cap.10300","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
The innovative double or triple dental abutment-implant: Case study with a 3-to-12-year follow-up.
Background: The aim of this case study is to present the rationality and scientific evidence of a new design for a double (DA) and triple (TA) dental abutment-implant with their specific new concept of biodynamic optimized peri-implant tissue (BOPiT).
Methods: The innovative design of these abutments with a paraboloid geometry was based on BOPiT, simultaneously involving the principles of mechanobiology, biotensegrity, and mechanotransduction. Thus, 37 consecutive individuals/43 cases rehabilitated with single dental implant using the innovative DA (n = 28) and TA (n = 15) on 43 implants were included in this case study. The DA and TA support 2 or 3 dental crowns on a single implant, respectively. Clinic and radiographic examinations were presented at T1 (loading after 4 months) and T2 [final examination with an average follow-up time of 7.2 years (>3 to 12 years)].
Results: At T2, mean scores for plaque index, peri-implant bleeding on probing, and peri-implant probing depth were low, depicting healthy peri-implant conditions. All radiographic images showed insignificant annual marginal bone loss (0.022 ± 0.05 mm) when compared to T1, reflecting great bone stability.
Conclusion: DA and TA, based on the BOPiT concept, represent an advantageous, simple and non-invasive mechanism for the longevity and healthy regulation of the peri-implant tissues.