通过计算机断层扫描对上肢骨移植部位进行三维分析。

IF 1.6 4区 医学 Journal of Orthopaedic Surgery Pub Date : 2024-05-01 DOI:10.1177/10225536241268607
Gregorio Alejandro Villarreal-Villarreal, Mario Simental-Mendía, Diego Arturo Ramírez Mendoza, Víctor Manuel Peña-Martínez, Adrian A Negreros-Osuna, Carlos Alberto Acosta-Olivo
{"title":"通过计算机断层扫描对上肢骨移植部位进行三维分析。","authors":"Gregorio Alejandro Villarreal-Villarreal, Mario Simental-Mendía, Diego Arturo Ramírez Mendoza, Víctor Manuel Peña-Martínez, Adrian A Negreros-Osuna, Carlos Alberto Acosta-Olivo","doi":"10.1177/10225536241268607","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To perform a quantitative analysis of the amount of cancellous bone in the distal radius and olecranon process by segmentation of computed tomographic scans. As a secondary analysis, the bone density by Hounsfield units was evaluated at the same sites.</p><p><strong>Methods: </strong>Computed tomography angiography images of the upper extremity were analyzed using 3-D Slicer™ medical imaging software. Bone volume (cm<sup>3</sup>) and density (Hounsfield units) from the cancellous bone between the distal radius and the olecranon process were compared by creating an advanced three-dimensional model. The images were analyzed in duplicate, and an intraclass correlation was performed to assess measurement consistency.</p><p><strong>Results: </strong>Twenty subjects were included. A total volume of 5.01 ± 1.21 cm<sup>3</sup> and 5.81 ± 1.61 cm<sup>3</sup> for the distal radius and the olecranon process (<i>p</i> < .0001), respectively, was found. Regarding Hounsfield units, the density of the olecranon process was 303.1 ± 73.26, and the distal radius was 206.5 ± 63.73 (<i>p</i> < .0001). All intraclass correlation coefficients were >0.992.</p><p><strong>Conclusion: </strong>These results suggest that the olecranon process has a greater volume and a higher bone mineral density than the distal radius. With these results, the surgeon will have the ability to decide the quantity and quality of bone grafts according to the surgical procedure.</p>","PeriodicalId":16608,"journal":{"name":"Journal of Orthopaedic Surgery","volume":"32 2","pages":"10225536241268607"},"PeriodicalIF":1.6000,"publicationDate":"2024-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Three-dimensional analysis of bone site grafting on the upper extremity on computed tomography scans.\",\"authors\":\"Gregorio Alejandro Villarreal-Villarreal, Mario Simental-Mendía, Diego Arturo Ramírez Mendoza, Víctor Manuel Peña-Martínez, Adrian A Negreros-Osuna, Carlos Alberto Acosta-Olivo\",\"doi\":\"10.1177/10225536241268607\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To perform a quantitative analysis of the amount of cancellous bone in the distal radius and olecranon process by segmentation of computed tomographic scans. As a secondary analysis, the bone density by Hounsfield units was evaluated at the same sites.</p><p><strong>Methods: </strong>Computed tomography angiography images of the upper extremity were analyzed using 3-D Slicer™ medical imaging software. Bone volume (cm<sup>3</sup>) and density (Hounsfield units) from the cancellous bone between the distal radius and the olecranon process were compared by creating an advanced three-dimensional model. The images were analyzed in duplicate, and an intraclass correlation was performed to assess measurement consistency.</p><p><strong>Results: </strong>Twenty subjects were included. A total volume of 5.01 ± 1.21 cm<sup>3</sup> and 5.81 ± 1.61 cm<sup>3</sup> for the distal radius and the olecranon process (<i>p</i> < .0001), respectively, was found. Regarding Hounsfield units, the density of the olecranon process was 303.1 ± 73.26, and the distal radius was 206.5 ± 63.73 (<i>p</i> < .0001). All intraclass correlation coefficients were >0.992.</p><p><strong>Conclusion: </strong>These results suggest that the olecranon process has a greater volume and a higher bone mineral density than the distal radius. With these results, the surgeon will have the ability to decide the quantity and quality of bone grafts according to the surgical procedure.</p>\",\"PeriodicalId\":16608,\"journal\":{\"name\":\"Journal of Orthopaedic Surgery\",\"volume\":\"32 2\",\"pages\":\"10225536241268607\"},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2024-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Orthopaedic Surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/10225536241268607\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Orthopaedic Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/10225536241268607","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的:通过对计算机断层扫描图像进行分割,对桡骨远端和锁骨突的松质骨量进行定量分析。作为辅助分析,用 Hounsfield 单位评估同一部位的骨密度:方法:使用 3-D Slicer™ 医学影像软件分析上肢的计算机断层扫描血管造影图像。通过创建先进的三维模型,比较桡骨远端和肩胛骨突之间松质骨的骨量(立方厘米)和密度(Hounsfield 单位)。对一式两份图像进行分析,并进行类内相关性分析以评估测量的一致性:结果:共纳入 20 名受试者。发现桡骨远端和肘突的总体积分别为 5.01 ± 1.21 cm3 和 5.81 ± 1.61 cm3(p < .0001)。就 Hounsfield 单位而言,肘突的密度为 303.1 ± 73.26,桡骨远端的密度为 206.5 ± 63.73(p < .0001)。所有类内相关系数均大于 0.992:这些结果表明,与桡骨远端相比,肩胛骨突的体积更大,骨矿密度更高。有了这些结果,外科医生就能根据手术方法决定骨移植的数量和质量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Three-dimensional analysis of bone site grafting on the upper extremity on computed tomography scans.

Purpose: To perform a quantitative analysis of the amount of cancellous bone in the distal radius and olecranon process by segmentation of computed tomographic scans. As a secondary analysis, the bone density by Hounsfield units was evaluated at the same sites.

Methods: Computed tomography angiography images of the upper extremity were analyzed using 3-D Slicer™ medical imaging software. Bone volume (cm3) and density (Hounsfield units) from the cancellous bone between the distal radius and the olecranon process were compared by creating an advanced three-dimensional model. The images were analyzed in duplicate, and an intraclass correlation was performed to assess measurement consistency.

Results: Twenty subjects were included. A total volume of 5.01 ± 1.21 cm3 and 5.81 ± 1.61 cm3 for the distal radius and the olecranon process (p < .0001), respectively, was found. Regarding Hounsfield units, the density of the olecranon process was 303.1 ± 73.26, and the distal radius was 206.5 ± 63.73 (p < .0001). All intraclass correlation coefficients were >0.992.

Conclusion: These results suggest that the olecranon process has a greater volume and a higher bone mineral density than the distal radius. With these results, the surgeon will have the ability to decide the quantity and quality of bone grafts according to the surgical procedure.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
91
期刊介绍: Journal of Orthopaedic Surgery is an open access peer-reviewed journal publishing original reviews and research articles on all aspects of orthopaedic surgery. It is the official journal of the Asia Pacific Orthopaedic Association. The journal welcomes and will publish materials of a diverse nature, from basic science research to clinical trials and surgical techniques. The journal encourages contributions from all parts of the world, but special emphasis is given to research of particular relevance to the Asia Pacific region.
期刊最新文献
Anxiety and depression as risk factors for postoperative complications and pain in lumbar spine surgery: A national database study Imaging evaluation of extraarticular posterior loose bodies in varus ankle osteoarthritis Oblique sliding ulna osteotomy to treat paediatric neglected monteggia fracture dislocation. Comparative analysis of changes in spinal dimensions following different correction methods in adult spinal deformity surgery. Letter to the editor regarding the article "knocking-down long non-coding RNA LINC01094 prohibits chondrocyte apoptosis via regulating microRNA-577/metal-regulatory transcription factor 1 axis".
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1