牙槽嵴保留范围内外植入种植体的临床评估:对 28 名患者进行为期 10 周观察的回顾性病例系列。

IF 2.2 4区 医学 Q2 DENTISTRY, ORAL SURGERY & MEDICINE Journal of Periodontal and Implant Science Pub Date : 2024-07-10 DOI:10.5051/jpis.2400800040
Young-Chang Ko, Ki-Tae Koo, Ling Li, Dongseob Lee, Yong-Moo Lee, Yang-Jo Seol, Tae-Hyung Kim, Jungwon Lee
{"title":"牙槽嵴保留范围内外植入种植体的临床评估:对 28 名患者进行为期 10 周观察的回顾性病例系列。","authors":"Young-Chang Ko, Ki-Tae Koo, Ling Li, Dongseob Lee, Yong-Moo Lee, Yang-Jo Seol, Tae-Hyung Kim, Jungwon Lee","doi":"10.5051/jpis.2400800040","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study investigated the effect of implant vertical positioning within alveolar ridge preservation (ARP) sites on implant stability quotient (ISQ) values, which were measured 10 weeks post-implantation.</p><p><strong>Methods: </strong>Patients who underwent ARP using collagenized deproteinized bovine bone mineral, followed by implant placement in the posterior area, were divided into 2 groups: the within-ARP group and the beyond-ARP group. In the within-ARP group, osteotomy and implant placement occurred within the ARP boundary. In contrast, in the beyond-ARP group, these procedures were performed beyond the ARP boundary, incorporating 3 mm of pristine bone at the implant's apex. Bone quality was assessed by tactile sense, and both insertion torque during implant surgery and ISQ values at 10 weeks post-implant surgery were measured. Multiple linear regression analysis and Pearson correlation analysis were used to explore the relationship between insertion torque and ISQ values.</p><p><strong>Results: </strong>In total, 30 ARP sites in 28 patients were analyzed. There was no significant difference in bone quality, as determined by tactile sense, between the within-ARP and beyond-ARP groups. At the time of implant placement, the beyond-ARP group exhibited a higher insertion torque (33.33±13.39 Ncm) compared to the within-ARP group (17.08±11.17 Ncm). However, the ISQ values were similar between the 2 groups 10 weeks after implant placement. A positive correlation between insertion torque and ISQ values was confirmed at 10 weeks post-implant.</p><p><strong>Conclusions: </strong>The engagement of pristine bone may facilitate high insertion torque during the placement of implants in ARP sites. Nevertheless, by 10 weeks post-implantation, the ISQ values were found to be comparable, irrespective of the implant's position.</p>","PeriodicalId":48795,"journal":{"name":"Journal of Periodontal and Implant Science","volume":" ","pages":""},"PeriodicalIF":2.2000,"publicationDate":"2024-07-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Clinical evaluation of implants placed within or beyond the boundaries of the alveolar ridge preservation: a retrospective case series with 10 weeks of observations in 28 patients.\",\"authors\":\"Young-Chang Ko, Ki-Tae Koo, Ling Li, Dongseob Lee, Yong-Moo Lee, Yang-Jo Seol, Tae-Hyung Kim, Jungwon Lee\",\"doi\":\"10.5051/jpis.2400800040\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>This study investigated the effect of implant vertical positioning within alveolar ridge preservation (ARP) sites on implant stability quotient (ISQ) values, which were measured 10 weeks post-implantation.</p><p><strong>Methods: </strong>Patients who underwent ARP using collagenized deproteinized bovine bone mineral, followed by implant placement in the posterior area, were divided into 2 groups: the within-ARP group and the beyond-ARP group. In the within-ARP group, osteotomy and implant placement occurred within the ARP boundary. In contrast, in the beyond-ARP group, these procedures were performed beyond the ARP boundary, incorporating 3 mm of pristine bone at the implant's apex. Bone quality was assessed by tactile sense, and both insertion torque during implant surgery and ISQ values at 10 weeks post-implant surgery were measured. Multiple linear regression analysis and Pearson correlation analysis were used to explore the relationship between insertion torque and ISQ values.</p><p><strong>Results: </strong>In total, 30 ARP sites in 28 patients were analyzed. There was no significant difference in bone quality, as determined by tactile sense, between the within-ARP and beyond-ARP groups. At the time of implant placement, the beyond-ARP group exhibited a higher insertion torque (33.33±13.39 Ncm) compared to the within-ARP group (17.08±11.17 Ncm). However, the ISQ values were similar between the 2 groups 10 weeks after implant placement. A positive correlation between insertion torque and ISQ values was confirmed at 10 weeks post-implant.</p><p><strong>Conclusions: </strong>The engagement of pristine bone may facilitate high insertion torque during the placement of implants in ARP sites. Nevertheless, by 10 weeks post-implantation, the ISQ values were found to be comparable, irrespective of the implant's position.</p>\",\"PeriodicalId\":48795,\"journal\":{\"name\":\"Journal of Periodontal and Implant Science\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":2.2000,\"publicationDate\":\"2024-07-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Periodontal and Implant Science\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.5051/jpis.2400800040\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Periodontal and Implant Science","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.5051/jpis.2400800040","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

目的:本研究探讨了牙槽嵴保留(ARP)部位内种植体垂直定位对种植体稳定性商(ISQ)值的影响:使用胶原蛋白化牛骨矿物质进行 ARP,然后在后部植入种植体的患者分为两组:ARP 内组和 ARP 外组。在 ARP 内组中,截骨和种植体植入均在 ARP 边界内进行。而在 ARP 以外组,这些手术在 ARP 边界以外进行,在种植体顶端植入 3 毫米的原始骨。通过触觉评估骨质,并测量种植手术中的插入扭矩和种植手术后 10 周的 ISQ 值。采用多元线性回归分析和皮尔逊相关分析来探讨插入扭矩和 ISQ 值之间的关系:共分析了 28 名患者的 30 个 ARP 位点。根据触觉判断,ARP内组和ARP外组的骨质无明显差异。在植入种植体时,ARP 外组的插入扭矩(33.33±13.39 Ncm)高于 ARP 内组(17.08±11.17 Ncm)。然而,两组患者在种植体植入 10 周后的 ISQ 值相似。种植体植入后 10 周时,植入扭矩和 ISQ 值之间的正相关性得到了证实:结论:在 ARP 位点植入种植体时,原始骨质的参与可能会促进较高的植入扭矩。尽管如此,在种植体植入后 10 周,无论种植体的位置如何,ISQ 值都是相当的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Clinical evaluation of implants placed within or beyond the boundaries of the alveolar ridge preservation: a retrospective case series with 10 weeks of observations in 28 patients.

Purpose: This study investigated the effect of implant vertical positioning within alveolar ridge preservation (ARP) sites on implant stability quotient (ISQ) values, which were measured 10 weeks post-implantation.

Methods: Patients who underwent ARP using collagenized deproteinized bovine bone mineral, followed by implant placement in the posterior area, were divided into 2 groups: the within-ARP group and the beyond-ARP group. In the within-ARP group, osteotomy and implant placement occurred within the ARP boundary. In contrast, in the beyond-ARP group, these procedures were performed beyond the ARP boundary, incorporating 3 mm of pristine bone at the implant's apex. Bone quality was assessed by tactile sense, and both insertion torque during implant surgery and ISQ values at 10 weeks post-implant surgery were measured. Multiple linear regression analysis and Pearson correlation analysis were used to explore the relationship between insertion torque and ISQ values.

Results: In total, 30 ARP sites in 28 patients were analyzed. There was no significant difference in bone quality, as determined by tactile sense, between the within-ARP and beyond-ARP groups. At the time of implant placement, the beyond-ARP group exhibited a higher insertion torque (33.33±13.39 Ncm) compared to the within-ARP group (17.08±11.17 Ncm). However, the ISQ values were similar between the 2 groups 10 weeks after implant placement. A positive correlation between insertion torque and ISQ values was confirmed at 10 weeks post-implant.

Conclusions: The engagement of pristine bone may facilitate high insertion torque during the placement of implants in ARP sites. Nevertheless, by 10 weeks post-implantation, the ISQ values were found to be comparable, irrespective of the implant's position.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Periodontal and Implant Science
Journal of Periodontal and Implant Science DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
3.30
自引率
5.30%
发文量
38
期刊介绍: Journal of Periodontal & Implant Science (JPIS) is a peer-reviewed and open-access journal providing up-to-date information relevant to professionalism of periodontology and dental implantology. JPIS is dedicated to global and extensive publication which includes evidence-based original articles, and fundamental reviews in order to cover a variety of interests in the field of periodontal as well as implant science.
期刊最新文献
Does defect configuration affect the outcomes of alveolar ridge preservation? An experimental in vivo study. Comprehensive treatment protocol for peri-implantitis: an up-to date narrative review of the literature. Guided bone regeneration of calcium phosphate-coated and strontium ranelate-doped titanium mesh in a rat calvarial defect model. Soft-tissue volume augmentation using a connective tissue graft and a volume-stable collagen matrix with polydeoxyribonucleotide for immediate implant placement: a pilot study in a dog model. The activin/BMP-2 chimera AB204 promotes periodontal tissue regeneration in a buccal dehiscence model: a pilot study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1