{"title":"不同皮肤缝合线挠曲强度的体外评估","authors":"Μaria Theofilaktidou, Leonidas Pavlidis, Ioannis Savvas, Vasileia Angellou, Apostolos Argyros, N. Michailidis, L. Papazoglou","doi":"10.1055/s-0044-1788577","DOIUrl":null,"url":null,"abstract":"\n Objective The aim of the study was to assess the flexural deformation strength of various brands of skin staples postfiring, and to compare the distance and alignment of the staple tips.\n Study Design In this experimental in vitro study, nine types of commercially available skin staples were tested. Following firing, six staples of each type were mounted on a material testing machine. Mechanical properties of staples were evaluated under uniaxial loading test, which translated to the bending of the staple for determination of flexural deformation strength. Staples were evaluated for tip alignment and distance between pointed tips.\n Results Maximum force to flexural deformation was greater for Precise (29.633 ± 7.8421 N), than Proximate (16.200 ± 1.1541 N; p = 0.000), Henry Schein (23.383 ± 5.2282 N; p = 0.011), Weck Visistat (24.329 ± 1.0372 N; p = 0.025), Appose (18.133 ± 1.2675 N; p = 0.000), Manipler (14.067 ± 3.7393 N; p = 0.000), and Leukoclip (22.288 ± 1.6915 N; p = 0.002) but was not different from Gima (27.483 ± 6.5637 N; p = 0.370) and Advan (27.283 ± 2.8708 N; p = 0.327) Precise, Appose, and Advan fired staples had their pointed tips met, whereas Manipler, Leukoclip, Gima, Henry Schein, Proximate, and Weck Visistat showed a gap between pointed tips. Proximate staples also showed malalignment between their pointed tips.\n Conclusion The flexural deformation strength of skin staples manufactured by Precise, Gima, and Advan was between 29 and 27 N and thus significantly superior to the other six staple types tested.","PeriodicalId":443672,"journal":{"name":"VCOT Open","volume":"27 13","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"In Vitro Evaluation of Flexural Strength of Different Skin Staples\",\"authors\":\"Μaria Theofilaktidou, Leonidas Pavlidis, Ioannis Savvas, Vasileia Angellou, Apostolos Argyros, N. Michailidis, L. Papazoglou\",\"doi\":\"10.1055/s-0044-1788577\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n Objective The aim of the study was to assess the flexural deformation strength of various brands of skin staples postfiring, and to compare the distance and alignment of the staple tips.\\n Study Design In this experimental in vitro study, nine types of commercially available skin staples were tested. Following firing, six staples of each type were mounted on a material testing machine. Mechanical properties of staples were evaluated under uniaxial loading test, which translated to the bending of the staple for determination of flexural deformation strength. Staples were evaluated for tip alignment and distance between pointed tips.\\n Results Maximum force to flexural deformation was greater for Precise (29.633 ± 7.8421 N), than Proximate (16.200 ± 1.1541 N; p = 0.000), Henry Schein (23.383 ± 5.2282 N; p = 0.011), Weck Visistat (24.329 ± 1.0372 N; p = 0.025), Appose (18.133 ± 1.2675 N; p = 0.000), Manipler (14.067 ± 3.7393 N; p = 0.000), and Leukoclip (22.288 ± 1.6915 N; p = 0.002) but was not different from Gima (27.483 ± 6.5637 N; p = 0.370) and Advan (27.283 ± 2.8708 N; p = 0.327) Precise, Appose, and Advan fired staples had their pointed tips met, whereas Manipler, Leukoclip, Gima, Henry Schein, Proximate, and Weck Visistat showed a gap between pointed tips. Proximate staples also showed malalignment between their pointed tips.\\n Conclusion The flexural deformation strength of skin staples manufactured by Precise, Gima, and Advan was between 29 and 27 N and thus significantly superior to the other six staple types tested.\",\"PeriodicalId\":443672,\"journal\":{\"name\":\"VCOT Open\",\"volume\":\"27 13\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"VCOT Open\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1055/s-0044-1788577\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"VCOT Open","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1055/s-0044-1788577","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

研究目的 评估各种品牌皮肤缝合钉烧结后的弯曲变形强度,并比较缝合钉尖端的距离和排列。研究设计 在这项体外实验研究中,测试了九种市售皮肤缝合钉。烧制后,每种类型的六枚订书针被安装在材料试验机上。在单轴加载测试下对皮钉的机械性能进行评估,即对皮钉进行弯曲以确定挠曲变形强度。对钉尖的排列和尖头之间的距离进行了评估。结果 Precise(29.633 ± 7.8421 N)比 Proximate(16.200 ± 1.1541 N;p = 0.000)、Henry Schein(23.383 ± 5.2282 N; p = 0.011)、Weck Visistat(24.329 ± 1.0372 N; p = 0.025)、Appose(18.133 ± 1.2675 N; p = 0.000)、Manipler(14.067 ± 3.7393 N; p = 0.Precise、Appose 和 Advan 发射钉的尖头相接,而 Manipler、Leukoclip、Gima、Henry Schein、Proximate 和 Weck Visistat 的尖头之间有间隙。Proximate 订书钉的尖头之间也有错位。结论 Precise、Gima 和 Advan 生产的皮肤缝合钉的弯曲变形强度介于 29 和 27 N 之间,因此明显优于其他六种受测缝合钉。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
In Vitro Evaluation of Flexural Strength of Different Skin Staples
Objective The aim of the study was to assess the flexural deformation strength of various brands of skin staples postfiring, and to compare the distance and alignment of the staple tips. Study Design In this experimental in vitro study, nine types of commercially available skin staples were tested. Following firing, six staples of each type were mounted on a material testing machine. Mechanical properties of staples were evaluated under uniaxial loading test, which translated to the bending of the staple for determination of flexural deformation strength. Staples were evaluated for tip alignment and distance between pointed tips. Results Maximum force to flexural deformation was greater for Precise (29.633 ± 7.8421 N), than Proximate (16.200 ± 1.1541 N; p = 0.000), Henry Schein (23.383 ± 5.2282 N; p = 0.011), Weck Visistat (24.329 ± 1.0372 N; p = 0.025), Appose (18.133 ± 1.2675 N; p = 0.000), Manipler (14.067 ± 3.7393 N; p = 0.000), and Leukoclip (22.288 ± 1.6915 N; p = 0.002) but was not different from Gima (27.483 ± 6.5637 N; p = 0.370) and Advan (27.283 ± 2.8708 N; p = 0.327) Precise, Appose, and Advan fired staples had their pointed tips met, whereas Manipler, Leukoclip, Gima, Henry Schein, Proximate, and Weck Visistat showed a gap between pointed tips. Proximate staples also showed malalignment between their pointed tips. Conclusion The flexural deformation strength of skin staples manufactured by Precise, Gima, and Advan was between 29 and 27 N and thus significantly superior to the other six staple types tested.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
In Vitro Evaluation of Flexural Strength of Different Skin Staples Surgical Approaches for Minimally Invasive Interlocking Nail Osteosynthesis in Dogs Intraoperative Distraction Device for Open Reduction of Nascent Lateral Humeral Condylar Fractures in Five Dogs Correction of Angular Limb Deformities in Two Dogs Using a Conformation-Based Surgical Approach and Planning Software Corrective Osteotomy in a Dog to Address Increased Distal Femoral Procurvatum Ascribed to a Distal Femoral Salter-Harris Type V Injury
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1