根据特定尺寸剂量估计值的分布,评估直接点剂量估计值。

IF 2.4 4区 医学 Q3 ENGINEERING, BIOMEDICAL Physical and Engineering Sciences in Medicine Pub Date : 2024-07-31 DOI:10.1007/s13246-024-01465-2
Choirul Anam, Heri Sutanto, Riska Amilia, Rini Marini, Sinta Nur Barokah, Noor Diyana Osman, Geoff Dougherty
{"title":"根据特定尺寸剂量估计值的分布,评估直接点剂量估计值。","authors":"Choirul Anam, Heri Sutanto, Riska Amilia, Rini Marini, Sinta Nur Barokah, Noor Diyana Osman, Geoff Dougherty","doi":"10.1007/s13246-024-01465-2","DOIUrl":null,"url":null,"abstract":"<p><p>The aim of this study was to evaluate the point doses using a distribution of the size-specific dose estimate (SSDE) from axial CT images of in-house phantoms having diameters from 8 to 40 cm. In-house phantoms made of polyester-resin (PESR) mixed with methyl ethyl ketone peroxide (MEKP) were used. The phantoms were built with different diameter sizes of 8, 16, 24, 32, and 40 cm. The phantoms were scanned by Siemens a SOMATOM Perspective-128 slice CT scanner with constant input parameters. The point doses were interpolated from the central SSDE (SSDEc) and the peripheral SSDE (SSDEp). The SSDEc and SSDEp were calculated from the SSDE with h- and k-factors. The point doses were compared to the direct measurements using the nanoDot™ optically-stimulated luminescence dosimeter (OSLD) in dedicated holes on the phantoms. It was found that the point dose decreases as the phantom diameter increased. The doses obtained using two approaches differed by 11% on average. The highest difference was 40% and the lowest difference was < 1%. It was found that dose based on the SSDE concept tended to be higher compared to the measured dose by OSLD. Point dose estimation using the concept of SSDE distribution can be considered an alternative for accurate and simple estimation. This approach still requires improvements to increase its accuracy and its application to estimate the organ dose needs further investigation.</p>","PeriodicalId":48490,"journal":{"name":"Physical and Engineering Sciences in Medicine","volume":null,"pages":null},"PeriodicalIF":2.4000,"publicationDate":"2024-07-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of direct point dose estimation based on the distribution of the size-specific dose estimate.\",\"authors\":\"Choirul Anam, Heri Sutanto, Riska Amilia, Rini Marini, Sinta Nur Barokah, Noor Diyana Osman, Geoff Dougherty\",\"doi\":\"10.1007/s13246-024-01465-2\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The aim of this study was to evaluate the point doses using a distribution of the size-specific dose estimate (SSDE) from axial CT images of in-house phantoms having diameters from 8 to 40 cm. In-house phantoms made of polyester-resin (PESR) mixed with methyl ethyl ketone peroxide (MEKP) were used. The phantoms were built with different diameter sizes of 8, 16, 24, 32, and 40 cm. The phantoms were scanned by Siemens a SOMATOM Perspective-128 slice CT scanner with constant input parameters. The point doses were interpolated from the central SSDE (SSDEc) and the peripheral SSDE (SSDEp). The SSDEc and SSDEp were calculated from the SSDE with h- and k-factors. The point doses were compared to the direct measurements using the nanoDot™ optically-stimulated luminescence dosimeter (OSLD) in dedicated holes on the phantoms. It was found that the point dose decreases as the phantom diameter increased. The doses obtained using two approaches differed by 11% on average. The highest difference was 40% and the lowest difference was < 1%. It was found that dose based on the SSDE concept tended to be higher compared to the measured dose by OSLD. Point dose estimation using the concept of SSDE distribution can be considered an alternative for accurate and simple estimation. This approach still requires improvements to increase its accuracy and its application to estimate the organ dose needs further investigation.</p>\",\"PeriodicalId\":48490,\"journal\":{\"name\":\"Physical and Engineering Sciences in Medicine\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.4000,\"publicationDate\":\"2024-07-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Physical and Engineering Sciences in Medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s13246-024-01465-2\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physical and Engineering Sciences in Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s13246-024-01465-2","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

本研究的目的是利用直径为 8 厘米至 40 厘米的内部模型轴向 CT 图像的尺寸特异性剂量估计值(SSDE)分布来评估点剂量。内部模型由聚酯树脂(PESR)和过氧化甲乙酮(MEKP)混合制成。模型的直径分别为 8、16、24、32 和 40 厘米。模型由西门子 SOMATOM Perspective-128 片 CT 扫描仪扫描,输入参数保持不变。点剂量由中央 SSDE(SSDEc)和外围 SSDE(SSDEp)内插得出。SSDEc 和 SSDEp 是根据带有 h 和 k 因子的 SSDE 计算得出的。点剂量与使用 nanoDot™ 光学刺激发光剂量计(OSLD)在模型上的专用孔中进行的直接测量结果进行了比较。结果发现,点剂量随着模型直径的增大而减小。使用两种方法获得的剂量平均相差 11%。最大差异为 40%,最小差异为
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Evaluation of direct point dose estimation based on the distribution of the size-specific dose estimate.

The aim of this study was to evaluate the point doses using a distribution of the size-specific dose estimate (SSDE) from axial CT images of in-house phantoms having diameters from 8 to 40 cm. In-house phantoms made of polyester-resin (PESR) mixed with methyl ethyl ketone peroxide (MEKP) were used. The phantoms were built with different diameter sizes of 8, 16, 24, 32, and 40 cm. The phantoms were scanned by Siemens a SOMATOM Perspective-128 slice CT scanner with constant input parameters. The point doses were interpolated from the central SSDE (SSDEc) and the peripheral SSDE (SSDEp). The SSDEc and SSDEp were calculated from the SSDE with h- and k-factors. The point doses were compared to the direct measurements using the nanoDot™ optically-stimulated luminescence dosimeter (OSLD) in dedicated holes on the phantoms. It was found that the point dose decreases as the phantom diameter increased. The doses obtained using two approaches differed by 11% on average. The highest difference was 40% and the lowest difference was < 1%. It was found that dose based on the SSDE concept tended to be higher compared to the measured dose by OSLD. Point dose estimation using the concept of SSDE distribution can be considered an alternative for accurate and simple estimation. This approach still requires improvements to increase its accuracy and its application to estimate the organ dose needs further investigation.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
8.40
自引率
4.50%
发文量
110
期刊最新文献
PET/CT-based 3D multi-class semantic segmentation of ovarian cancer and the stability of the extracted radiomics features. PPG2RespNet: a deep learning model for respirational signal synthesis and monitoring from photoplethysmography (PPG) signal Ecg signal watermarking using QR decomposition Effect of mirror system and scanner bed of a flatbed scanner on lateral response artefact in radiochromic film dosimetry A deep learning phase-based solution in 2D echocardiography motion estimation
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1