厌氧条件下钴铬钼合金在模拟体液中的摩擦腐蚀行为

IF 5.3 1区 工程技术 Q1 ENGINEERING, MECHANICAL Wear Pub Date : 2024-07-31 DOI:10.1016/j.wear.2024.205523
J. Qi , T. Cole , A. Foster , W.M. Rainforth
{"title":"厌氧条件下钴铬钼合金在模拟体液中的摩擦腐蚀行为","authors":"J. Qi ,&nbsp;T. Cole ,&nbsp;A. Foster ,&nbsp;W.M. Rainforth","doi":"10.1016/j.wear.2024.205523","DOIUrl":null,"url":null,"abstract":"<div><p>CoCrMo has been used as an implant material for a long time due to its excellent combination of strength, corrosion resistance and biocompatibility. The formation of a thin passive oxide film on the surface of the material plays a crucial role in its performance. This passive film can be ruptured during contact between two surfaces, but usually reforms in short timescales. However, the reformation of the film depends on the availability of oxygen in the surrounding fluid. The oxygen level in human tissue, cartilage and synovial fluid, around which the implant is situated, is much lower than that in laboratory testing under open-air conditions. Moreover, the local oxygen concentration and pH values in the body vary from patient to patient, depending on the patient's health condition and other factors, which leads to variation in the corrosion resistance of metallic implants. Therefore, an implant that performs well at one time may still experience an undesirable level of corrosion at another. Thus, evaluation of the tribocorrosion of implant materials carried out in open-air conditions does not reflect the actual process the implants undergo once in the body, particularly if there is irritation due to injury or surgery. In this study, we investigate the tribocorrosion behaviour of CoCrMo in bioactive solutions under fully aerobic to anaerobic conditions with varying loads/contact pressures. The anaerobic condition leads to a reduction in wear rate and a reduction in the extent of tribofilm formation but does not have an appreciable effect on friction. The mechanisms are discussed in detail.</p></div>","PeriodicalId":23970,"journal":{"name":"Wear","volume":"556 ","pages":"Article 205523"},"PeriodicalIF":5.3000,"publicationDate":"2024-07-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S0043164824002886/pdfft?md5=5b66bc9579dcc2b23f95815f7320f7c3&pid=1-s2.0-S0043164824002886-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Tribocorrosion behaviour of CoCrMo in simulated body fluid under anaerobic conditions\",\"authors\":\"J. Qi ,&nbsp;T. Cole ,&nbsp;A. Foster ,&nbsp;W.M. Rainforth\",\"doi\":\"10.1016/j.wear.2024.205523\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>CoCrMo has been used as an implant material for a long time due to its excellent combination of strength, corrosion resistance and biocompatibility. The formation of a thin passive oxide film on the surface of the material plays a crucial role in its performance. This passive film can be ruptured during contact between two surfaces, but usually reforms in short timescales. However, the reformation of the film depends on the availability of oxygen in the surrounding fluid. The oxygen level in human tissue, cartilage and synovial fluid, around which the implant is situated, is much lower than that in laboratory testing under open-air conditions. Moreover, the local oxygen concentration and pH values in the body vary from patient to patient, depending on the patient's health condition and other factors, which leads to variation in the corrosion resistance of metallic implants. Therefore, an implant that performs well at one time may still experience an undesirable level of corrosion at another. Thus, evaluation of the tribocorrosion of implant materials carried out in open-air conditions does not reflect the actual process the implants undergo once in the body, particularly if there is irritation due to injury or surgery. In this study, we investigate the tribocorrosion behaviour of CoCrMo in bioactive solutions under fully aerobic to anaerobic conditions with varying loads/contact pressures. The anaerobic condition leads to a reduction in wear rate and a reduction in the extent of tribofilm formation but does not have an appreciable effect on friction. The mechanisms are discussed in detail.</p></div>\",\"PeriodicalId\":23970,\"journal\":{\"name\":\"Wear\",\"volume\":\"556 \",\"pages\":\"Article 205523\"},\"PeriodicalIF\":5.3000,\"publicationDate\":\"2024-07-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S0043164824002886/pdfft?md5=5b66bc9579dcc2b23f95815f7320f7c3&pid=1-s2.0-S0043164824002886-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Wear\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0043164824002886\",\"RegionNum\":1,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENGINEERING, MECHANICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Wear","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0043164824002886","RegionNum":1,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, MECHANICAL","Score":null,"Total":0}
引用次数: 0

摘要

CoCrMo 因其出色的强度、耐腐蚀性和生物相容性,长期以来一直被用作植入材料。材料表面形成的一层薄薄的被动氧化膜对其性能起着至关重要的作用。这种被动膜在两个表面接触时可能会破裂,但通常会在短时间内重整。不过,薄膜的重整取决于周围液体中氧气的含量。植入物周围的人体组织、软骨和滑液中的氧含量远低于实验室在露天条件下进行的测试。此外,不同患者体内的局部氧气浓度和 pH 值也不尽相同,这取决于患者的健康状况和其他因素,从而导致金属植入物的耐腐蚀性能发生变化。因此,在某一时期表现良好的植入体,在另一时期可能仍会出现不理想的腐蚀程度。因此,在露天条件下对植入物材料进行摩擦腐蚀评估并不能反映植入物进入人体后的实际过程,尤其是在受伤或手术造成刺激的情况下。在这项研究中,我们研究了钴铬钼合金在生物活性溶液中,在完全有氧和无氧条件下,不同载荷/接触压力下的摩擦腐蚀行为。厌氧条件导致磨损率降低,三膜形成程度减小,但对摩擦力没有明显影响。本文详细讨论了其中的机理。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Tribocorrosion behaviour of CoCrMo in simulated body fluid under anaerobic conditions

CoCrMo has been used as an implant material for a long time due to its excellent combination of strength, corrosion resistance and biocompatibility. The formation of a thin passive oxide film on the surface of the material plays a crucial role in its performance. This passive film can be ruptured during contact between two surfaces, but usually reforms in short timescales. However, the reformation of the film depends on the availability of oxygen in the surrounding fluid. The oxygen level in human tissue, cartilage and synovial fluid, around which the implant is situated, is much lower than that in laboratory testing under open-air conditions. Moreover, the local oxygen concentration and pH values in the body vary from patient to patient, depending on the patient's health condition and other factors, which leads to variation in the corrosion resistance of metallic implants. Therefore, an implant that performs well at one time may still experience an undesirable level of corrosion at another. Thus, evaluation of the tribocorrosion of implant materials carried out in open-air conditions does not reflect the actual process the implants undergo once in the body, particularly if there is irritation due to injury or surgery. In this study, we investigate the tribocorrosion behaviour of CoCrMo in bioactive solutions under fully aerobic to anaerobic conditions with varying loads/contact pressures. The anaerobic condition leads to a reduction in wear rate and a reduction in the extent of tribofilm formation but does not have an appreciable effect on friction. The mechanisms are discussed in detail.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Wear
Wear 工程技术-材料科学:综合
CiteScore
8.80
自引率
8.00%
发文量
280
审稿时长
47 days
期刊介绍: Wear journal is dedicated to the advancement of basic and applied knowledge concerning the nature of wear of materials. Broadly, topics of interest range from development of fundamental understanding of the mechanisms of wear to innovative solutions to practical engineering problems. Authors of experimental studies are expected to comment on the repeatability of the data, and whenever possible, conduct multiple measurements under similar testing conditions. Further, Wear embraces the highest standards of professional ethics, and the detection of matching content, either in written or graphical form, from other publications by the current authors or by others, may result in rejection.
期刊最新文献
Effect of normal load on damage mechanism of gradient copper-graphite composites under electric current Assessment of simulated and observed cavitation-induced erosion damage in spallation neutron source target vessels Derivative analysis and evaluation of roll-slip fretting wear mechanism of ultra-thin-walled bearings under high service Microstructure, mechanical properties and high-temperature sliding wear response of a new Al0.5CrFeNiV0.5 high-entropy alloy Editorial Board
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1