{"title":"超声引导下真空辅助乳腺活检在处理放射学与病理学不一致中的作用:一项回顾性单中心研究。","authors":"Giulia Vatteroni, Giulia Pinna, Rubina Manuela Trimboli, Riccardo Levi, Isabella Bolengo, Francesco Patrone, Daria Volpe, Bethania Fernandes, Daniela Bernardi","doi":"10.1007/s11547-024-01864-1","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the efficacy of US-guided vacuum-assisted biopsy (US-VAB) in radiologic-pathologic (rad-path) discordance in women with suspicious breast lesions.</p><p><strong>Methods: </strong>Two thousand three hundred and sixty patients with 2385 BI-RADS category 4 and 5 lesions underwent percutaneous US-guided CNB. Thirty-six lesions were classified as discordant benign and underwent second-line US-VAB. A 14-gauge needle was utilized for CNB and 10-gauge for US-VAB. Final pathology was the reference standard for women who underwent surgery, imaging follow-up in other cases. Rates of malignancy for US-VAB and subsequent surgery were evaluated. Lesions with upgrade and no upgrade to second-line VAB were compared in terms of patient's age, lesion type and characteristics, size and BI-RADS category. Positive predictive value (PPV), negative predictive value (NPV) for BI-RADS categories and diagnostic performance for second-line US-VAB were calculated. p value < 0.05 was considered statistically significant (t-test, Mann-Whitney, χ<sup>2</sup>).</p><p><strong>Results: </strong>US-VAB identified 10 B2, 9 B3 and 17 B5 lesions with upgrade to malignancy of 47.2% (17/36). There were 8 invasive no special type, 7 ductal in situ, 1 invasive lobular carcinoma and 1 angiosarcoma, and their distribution among BI-RADS categories was: 2/2 in BI-RADS 5 (100%), 12/18 in BI-RADS 4C (67%) and 3/16 in BI-RADS 4B lesions (19%) (p = 0.006). Of the remaining 19 lesions, 6 underwent surgery and 2 were upgraded to ductal carcinoma in situ; 13 underwent radiological follow-up and one resulted malignant. False-negative rate for US-VAB was 15.8% (3/19) with final upgrade to malignancy of 55% (20/36). The univariate analysis revealed mass shape (p = 0.008) and BI-RADS categories (p = 0.006) to be associated with upgrade to malignancy. Sensitivity, specificity, PPV, NPV and accuracy for US-VAB were 85, 100, 100, 84 and 92%, respectively.</p><p><strong>Conclusions: </strong>US-VAB identified almost 50% of cancers missed by CNB, avoiding surgical biopsies and validating as an effective mini-invasive approach in rad-path discordance.</p>","PeriodicalId":20817,"journal":{"name":"Radiologia Medica","volume":" ","pages":"1454-1462"},"PeriodicalIF":9.7000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Role of ultrasound-guided vacuum-assisted breast biopsy in the management of radiologic-pathologic discordance: a retrospective single-centre study.\",\"authors\":\"Giulia Vatteroni, Giulia Pinna, Rubina Manuela Trimboli, Riccardo Levi, Isabella Bolengo, Francesco Patrone, Daria Volpe, Bethania Fernandes, Daniela Bernardi\",\"doi\":\"10.1007/s11547-024-01864-1\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To evaluate the efficacy of US-guided vacuum-assisted biopsy (US-VAB) in radiologic-pathologic (rad-path) discordance in women with suspicious breast lesions.</p><p><strong>Methods: </strong>Two thousand three hundred and sixty patients with 2385 BI-RADS category 4 and 5 lesions underwent percutaneous US-guided CNB. Thirty-six lesions were classified as discordant benign and underwent second-line US-VAB. A 14-gauge needle was utilized for CNB and 10-gauge for US-VAB. Final pathology was the reference standard for women who underwent surgery, imaging follow-up in other cases. Rates of malignancy for US-VAB and subsequent surgery were evaluated. Lesions with upgrade and no upgrade to second-line VAB were compared in terms of patient's age, lesion type and characteristics, size and BI-RADS category. Positive predictive value (PPV), negative predictive value (NPV) for BI-RADS categories and diagnostic performance for second-line US-VAB were calculated. p value < 0.05 was considered statistically significant (t-test, Mann-Whitney, χ<sup>2</sup>).</p><p><strong>Results: </strong>US-VAB identified 10 B2, 9 B3 and 17 B5 lesions with upgrade to malignancy of 47.2% (17/36). There were 8 invasive no special type, 7 ductal in situ, 1 invasive lobular carcinoma and 1 angiosarcoma, and their distribution among BI-RADS categories was: 2/2 in BI-RADS 5 (100%), 12/18 in BI-RADS 4C (67%) and 3/16 in BI-RADS 4B lesions (19%) (p = 0.006). Of the remaining 19 lesions, 6 underwent surgery and 2 were upgraded to ductal carcinoma in situ; 13 underwent radiological follow-up and one resulted malignant. False-negative rate for US-VAB was 15.8% (3/19) with final upgrade to malignancy of 55% (20/36). The univariate analysis revealed mass shape (p = 0.008) and BI-RADS categories (p = 0.006) to be associated with upgrade to malignancy. Sensitivity, specificity, PPV, NPV and accuracy for US-VAB were 85, 100, 100, 84 and 92%, respectively.</p><p><strong>Conclusions: </strong>US-VAB identified almost 50% of cancers missed by CNB, avoiding surgical biopsies and validating as an effective mini-invasive approach in rad-path discordance.</p>\",\"PeriodicalId\":20817,\"journal\":{\"name\":\"Radiologia Medica\",\"volume\":\" \",\"pages\":\"1454-1462\"},\"PeriodicalIF\":9.7000,\"publicationDate\":\"2024-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Radiologia Medica\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s11547-024-01864-1\",\"RegionNum\":1,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/8/5 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiologia Medica","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s11547-024-01864-1","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/5 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
Role of ultrasound-guided vacuum-assisted breast biopsy in the management of radiologic-pathologic discordance: a retrospective single-centre study.
Purpose: To evaluate the efficacy of US-guided vacuum-assisted biopsy (US-VAB) in radiologic-pathologic (rad-path) discordance in women with suspicious breast lesions.
Methods: Two thousand three hundred and sixty patients with 2385 BI-RADS category 4 and 5 lesions underwent percutaneous US-guided CNB. Thirty-six lesions were classified as discordant benign and underwent second-line US-VAB. A 14-gauge needle was utilized for CNB and 10-gauge for US-VAB. Final pathology was the reference standard for women who underwent surgery, imaging follow-up in other cases. Rates of malignancy for US-VAB and subsequent surgery were evaluated. Lesions with upgrade and no upgrade to second-line VAB were compared in terms of patient's age, lesion type and characteristics, size and BI-RADS category. Positive predictive value (PPV), negative predictive value (NPV) for BI-RADS categories and diagnostic performance for second-line US-VAB were calculated. p value < 0.05 was considered statistically significant (t-test, Mann-Whitney, χ2).
Results: US-VAB identified 10 B2, 9 B3 and 17 B5 lesions with upgrade to malignancy of 47.2% (17/36). There were 8 invasive no special type, 7 ductal in situ, 1 invasive lobular carcinoma and 1 angiosarcoma, and their distribution among BI-RADS categories was: 2/2 in BI-RADS 5 (100%), 12/18 in BI-RADS 4C (67%) and 3/16 in BI-RADS 4B lesions (19%) (p = 0.006). Of the remaining 19 lesions, 6 underwent surgery and 2 were upgraded to ductal carcinoma in situ; 13 underwent radiological follow-up and one resulted malignant. False-negative rate for US-VAB was 15.8% (3/19) with final upgrade to malignancy of 55% (20/36). The univariate analysis revealed mass shape (p = 0.008) and BI-RADS categories (p = 0.006) to be associated with upgrade to malignancy. Sensitivity, specificity, PPV, NPV and accuracy for US-VAB were 85, 100, 100, 84 and 92%, respectively.
Conclusions: US-VAB identified almost 50% of cancers missed by CNB, avoiding surgical biopsies and validating as an effective mini-invasive approach in rad-path discordance.
期刊介绍:
Felice Perussia founded La radiologia medica in 1914. It is a peer-reviewed journal and serves as the official journal of the Italian Society of Medical and Interventional Radiology (SIRM). The primary purpose of the journal is to disseminate information related to Radiology, especially advancements in diagnostic imaging and related disciplines. La radiologia medica welcomes original research on both fundamental and clinical aspects of modern radiology, with a particular focus on diagnostic and interventional imaging techniques. It also covers topics such as radiotherapy, nuclear medicine, radiobiology, health physics, and artificial intelligence in the context of clinical implications. The journal includes various types of contributions such as original articles, review articles, editorials, short reports, and letters to the editor. With an esteemed Editorial Board and a selection of insightful reports, the journal is an indispensable resource for radiologists and professionals in related fields. Ultimately, La radiologia medica aims to serve as a platform for international collaboration and knowledge sharing within the radiological community.