使用两种型号的后房型法康眼内透镜对穹窿进行表征。

IF 2.6 3区 医学 Q2 OPHTHALMOLOGY Journal of cataract and refractive surgery Pub Date : 2024-12-01 DOI:10.1097/j.jcrs.0000000000001536
Beatriz Paredes, Javier Mora de Oñate, Dolores Martín Sánchez, David P Piñero
{"title":"使用两种型号的后房型法康眼内透镜对穹窿进行表征。","authors":"Beatriz Paredes, Javier Mora de Oñate, Dolores Martín Sánchez, David P Piñero","doi":"10.1097/j.jcrs.0000000000001536","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate and compare dynamic vault range (DVR) and asymmetry of the vault during a 3-month follow-up after the implantation of 2 posterior chamber phakic intraocular lenses (pIOLs).</p><p><strong>Setting: </strong>Aver Clinic, Madrid, Spain.</p><p><strong>Design: </strong>Prospective comparative study.</p><p><strong>Methods: </strong>119 eyes (65 patients) that underwent refractive surgical correction with implantation of 1 of 2 distinct pIOLs were enrolled: Eyecryl Phakic from Biotech Vision Care (Eyecryl group, 72 eyes) and Evo Visian Implantable Contact Lens from Staar Surgical (ICL group, 47 eyes). Besides evaluation of visual acuity, refraction, and ocular integrity, the pIOL vault centrally and at 2 mm nasally and temporally as well as the DVR from photopic (50 lux) to mesopic (10 lux) illumination conditions were measured.</p><p><strong>Results: </strong>No significant differences were found between the pIOL groups in visual and refractive outcomes ( P ≥ .454). No significant differences between the groups were found in central (523.72 ± 168.4 vs 494.16 ± 156.7 μm, P = .248) and temporal (499.43 ± 155.8 vs 431.28 ± 150.5 μm, P = .067) vaults. However, nasal vault was significantly lower in the ICL group (465.6 ± 149.1 vs 375.4 ± 144.0 μm, P = .045). A trend of a larger DVR was observed in the ICL group, although differences between groups did not reach statistical significance (54.00 ± 36.39 vs 86.5 ± 57.9 μm, P = .070). The pIOL diameter only correlated significantly with vault measurements in the ICL group ( r ≥ 0.650, P < .001).</p><p><strong>Conclusions: </strong>The Eyecryl pIOL showed more symmetric vaults and a trend of fewer light-induced changes in the central vault compared with the ICL pIOL. The clinical relevance of this finding should be investigated further.</p>","PeriodicalId":15214,"journal":{"name":"Journal of cataract and refractive surgery","volume":" ","pages":"1262-1269"},"PeriodicalIF":2.6000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11556799/pdf/","citationCount":"0","resultStr":"{\"title\":\"Characterization of vault with two models of posterior chamber phakic intraocular lenses.\",\"authors\":\"Beatriz Paredes, Javier Mora de Oñate, Dolores Martín Sánchez, David P Piñero\",\"doi\":\"10.1097/j.jcrs.0000000000001536\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To evaluate and compare dynamic vault range (DVR) and asymmetry of the vault during a 3-month follow-up after the implantation of 2 posterior chamber phakic intraocular lenses (pIOLs).</p><p><strong>Setting: </strong>Aver Clinic, Madrid, Spain.</p><p><strong>Design: </strong>Prospective comparative study.</p><p><strong>Methods: </strong>119 eyes (65 patients) that underwent refractive surgical correction with implantation of 1 of 2 distinct pIOLs were enrolled: Eyecryl Phakic from Biotech Vision Care (Eyecryl group, 72 eyes) and Evo Visian Implantable Contact Lens from Staar Surgical (ICL group, 47 eyes). Besides evaluation of visual acuity, refraction, and ocular integrity, the pIOL vault centrally and at 2 mm nasally and temporally as well as the DVR from photopic (50 lux) to mesopic (10 lux) illumination conditions were measured.</p><p><strong>Results: </strong>No significant differences were found between the pIOL groups in visual and refractive outcomes ( P ≥ .454). No significant differences between the groups were found in central (523.72 ± 168.4 vs 494.16 ± 156.7 μm, P = .248) and temporal (499.43 ± 155.8 vs 431.28 ± 150.5 μm, P = .067) vaults. However, nasal vault was significantly lower in the ICL group (465.6 ± 149.1 vs 375.4 ± 144.0 μm, P = .045). A trend of a larger DVR was observed in the ICL group, although differences between groups did not reach statistical significance (54.00 ± 36.39 vs 86.5 ± 57.9 μm, P = .070). The pIOL diameter only correlated significantly with vault measurements in the ICL group ( r ≥ 0.650, P < .001).</p><p><strong>Conclusions: </strong>The Eyecryl pIOL showed more symmetric vaults and a trend of fewer light-induced changes in the central vault compared with the ICL pIOL. The clinical relevance of this finding should be investigated further.</p>\",\"PeriodicalId\":15214,\"journal\":{\"name\":\"Journal of cataract and refractive surgery\",\"volume\":\" \",\"pages\":\"1262-1269\"},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2024-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11556799/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of cataract and refractive surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/j.jcrs.0000000000001536\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of cataract and refractive surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/j.jcrs.0000000000001536","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的: 评估并比较两种后房型人工晶体(pIOL)植入后 3 个月随访期间的动态穹窿范围(DVR)和穹窿不对称情况:设计:前瞻性比较研究:设计:前瞻性比较研究:方法:研究对象包括接受屈光手术矫正并植入两种不同人工晶体之一的 119 只眼睛(65 名患者):Biotech Vision Care 公司的 Eyecryl Phakic(Eyecryl 组,72 只眼睛)和 Staar Surgical 公司的 Evo Visian Implantable Contact Lens(ICL 组,47 只眼睛)。除了对视力、屈光度和眼球完整性进行评估外,还测量了pIOL穹窿的中心位置、鼻侧和颞侧2毫米的位置,以及从光照(50勒克斯)到中光照(10勒克斯)条件下的DVR:在视觉和屈光结果方面,pIOL 组间无明显差异(p≥0.454)。中心穹窿(523.72±168.4 vs. 494.16±156.7 µm,p=0.248)和颞穹窿(499.43±155.8 vs. 431.28±150.5 µm,p=0.067)组间无明显差异。然而,ICL 组的鼻穹隆明显较低(465.6±149.1 vs. 375.4±144.0 µm,p=0.045)。虽然组间差异未达到统计学意义(54.00±36.39 vs. 86.5±57.9 µm, p=0.070),但在 ICL 组中观察到 DVR 变大的趋势。只有 ICL 组的 pIOL 直径与穹窿测量值有显著相关性(r≥0.650,p 结论:与 ICL pIOL 相比,Eyecryl pIOL 显示出更对称的穹窿,并且中央穹窿由光线引起的变化有减少的趋势。这一发现的临床意义有待进一步研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Characterization of vault with two models of posterior chamber phakic intraocular lenses.

Purpose: To evaluate and compare dynamic vault range (DVR) and asymmetry of the vault during a 3-month follow-up after the implantation of 2 posterior chamber phakic intraocular lenses (pIOLs).

Setting: Aver Clinic, Madrid, Spain.

Design: Prospective comparative study.

Methods: 119 eyes (65 patients) that underwent refractive surgical correction with implantation of 1 of 2 distinct pIOLs were enrolled: Eyecryl Phakic from Biotech Vision Care (Eyecryl group, 72 eyes) and Evo Visian Implantable Contact Lens from Staar Surgical (ICL group, 47 eyes). Besides evaluation of visual acuity, refraction, and ocular integrity, the pIOL vault centrally and at 2 mm nasally and temporally as well as the DVR from photopic (50 lux) to mesopic (10 lux) illumination conditions were measured.

Results: No significant differences were found between the pIOL groups in visual and refractive outcomes ( P ≥ .454). No significant differences between the groups were found in central (523.72 ± 168.4 vs 494.16 ± 156.7 μm, P = .248) and temporal (499.43 ± 155.8 vs 431.28 ± 150.5 μm, P = .067) vaults. However, nasal vault was significantly lower in the ICL group (465.6 ± 149.1 vs 375.4 ± 144.0 μm, P = .045). A trend of a larger DVR was observed in the ICL group, although differences between groups did not reach statistical significance (54.00 ± 36.39 vs 86.5 ± 57.9 μm, P = .070). The pIOL diameter only correlated significantly with vault measurements in the ICL group ( r ≥ 0.650, P < .001).

Conclusions: The Eyecryl pIOL showed more symmetric vaults and a trend of fewer light-induced changes in the central vault compared with the ICL pIOL. The clinical relevance of this finding should be investigated further.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
5.60
自引率
14.30%
发文量
259
审稿时长
8.5 weeks
期刊介绍: The Journal of Cataract & Refractive Surgery (JCRS), a preeminent peer-reviewed monthly ophthalmology publication, is the official journal of the American Society of Cataract and Refractive Surgery (ASCRS) and the European Society of Cataract and Refractive Surgeons (ESCRS). JCRS publishes high quality articles on all aspects of anterior segment surgery. In addition to original clinical studies, the journal features a consultation section, practical techniques, important cases, and reviews as well as basic science articles.
期刊最新文献
Comparing visual outcomes of keratorefractive lenticule extraction, PRK, and LASIK procedures in the military population. Endophthalmitis rates after secondary intraocular lens surgeries: 11-year Medicare fee-for-service analysis. Longitudinal outcomes of iStent inject with cataract surgery compared with cataract surgery alone: real-world data from the Fight Glaucoma Blindness registry. Comparison of intraocular lens power formulas for negative diopter intraocular lens implantation for high myopia. Virtual follow-up after cataract surgery: systematic review.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1