{"title":"不同轴长白内障患者植入 PanOptix 三焦点眼内透镜后视觉质量改善情况分析。","authors":"Yin-Ping Yang, Ya Tan, Qiong Liao","doi":"10.62347/FRJZ4885","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To assess the visual quality, both subjective and objective, of cataract patients with varying axial lengths (AL) after PanOptix trifocal intraocular lens (IOL) implantation and investigated the lens tilt and its correlation with visual outcomes.</p><p><strong>Methods: </strong>From July 2020 to June 2022, 70 patients (140 eyes) diagnosed with age-related cataracts and undergoing PanOptix implantation at Chongqing Eye and Vision Care Hospital, Aier Eye Hospital Group, were included. Patients were assigned to either the observation group (35 cases, 70 eyes with PanOptix trifocal IOL) or the control group (35 cases, 70 eyes with bifocal IOL). Patients were further subdivided based on AL into AL < 24 mm (observation group: 23 eyes; control group: 26 eyes) and AL ≥ 24 mm (observation group: 47 eyes; control group: 44 eyes). Postoperative follow-up lasted three months. Visual acuity (distant, intermediate, near), objective visual quality (Strehl ratio: SR, total eye modulation transfer function (MTF)), and visual aberrations were measured preoperatively and at 3 months post-operation.</p><p><strong>Results: </strong>Postoperatively, all groups saw significant improvements in uncorrected distance visual acuity (UCDVA), uncorrected intermediate visual acuity (UCIVA), and uncorrected near visual acuity (UCNVA) compared to preoperative values (T0) (all P < 0.05). Notably, UCIVA was significantly better in the observation group than in the control group (P < 0.05). At three months (T1), reductions in total high-order aberration (tHOA), internal high-order aberration (iHOA), coma, and trefoil aberrations were observed in both groups compared to baseline, with more significant decreases in the observation group (all P < 0.05). Both SR and MTF cutoff showed marked improvement from T0 to T1, with the observation group experiencing greater enhancements (both P < 0.05). The defocus curve of the observation group showed a gentle slope between +0.5 D and -3.0 D, maintaining superior visual acuity compared to the control group (P < 0.05). Subjective visual quality scores at T1 were significantly higher than at T0 for both groups (P < 0.05), with patients in the observation group scoring higher than those in the control group across all AL categories (P < 0.05). Spearman correlation analysis indicated that the tilt after PanOptix trifocal IOL implantation was associated with tHOA (r = 0.273, P = 0.022), iHOA (r = 0.433, P < 0.001), Trefoil (r = 0.360, P = 0.002) and coma (r = 0.688, P < 0.001).</p><p><strong>Conclusion: </strong>PanOptix trifocal IOL implantation in cataract patients across different AL significantly enhances visual quality compared to bifocal IOLs, suggesting a strong case for its clinical adoption.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2024-07-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11301498/pdf/","citationCount":"0","resultStr":"{\"title\":\"Analysis of visual quality improvement after implantation of PanOptix trifocal intraocular lens in cataract patients with different axial lengths.\",\"authors\":\"Yin-Ping Yang, Ya Tan, Qiong Liao\",\"doi\":\"10.62347/FRJZ4885\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>To assess the visual quality, both subjective and objective, of cataract patients with varying axial lengths (AL) after PanOptix trifocal intraocular lens (IOL) implantation and investigated the lens tilt and its correlation with visual outcomes.</p><p><strong>Methods: </strong>From July 2020 to June 2022, 70 patients (140 eyes) diagnosed with age-related cataracts and undergoing PanOptix implantation at Chongqing Eye and Vision Care Hospital, Aier Eye Hospital Group, were included. Patients were assigned to either the observation group (35 cases, 70 eyes with PanOptix trifocal IOL) or the control group (35 cases, 70 eyes with bifocal IOL). Patients were further subdivided based on AL into AL < 24 mm (observation group: 23 eyes; control group: 26 eyes) and AL ≥ 24 mm (observation group: 47 eyes; control group: 44 eyes). Postoperative follow-up lasted three months. Visual acuity (distant, intermediate, near), objective visual quality (Strehl ratio: SR, total eye modulation transfer function (MTF)), and visual aberrations were measured preoperatively and at 3 months post-operation.</p><p><strong>Results: </strong>Postoperatively, all groups saw significant improvements in uncorrected distance visual acuity (UCDVA), uncorrected intermediate visual acuity (UCIVA), and uncorrected near visual acuity (UCNVA) compared to preoperative values (T0) (all P < 0.05). Notably, UCIVA was significantly better in the observation group than in the control group (P < 0.05). At three months (T1), reductions in total high-order aberration (tHOA), internal high-order aberration (iHOA), coma, and trefoil aberrations were observed in both groups compared to baseline, with more significant decreases in the observation group (all P < 0.05). Both SR and MTF cutoff showed marked improvement from T0 to T1, with the observation group experiencing greater enhancements (both P < 0.05). The defocus curve of the observation group showed a gentle slope between +0.5 D and -3.0 D, maintaining superior visual acuity compared to the control group (P < 0.05). Subjective visual quality scores at T1 were significantly higher than at T0 for both groups (P < 0.05), with patients in the observation group scoring higher than those in the control group across all AL categories (P < 0.05). Spearman correlation analysis indicated that the tilt after PanOptix trifocal IOL implantation was associated with tHOA (r = 0.273, P = 0.022), iHOA (r = 0.433, P < 0.001), Trefoil (r = 0.360, P = 0.002) and coma (r = 0.688, P < 0.001).</p><p><strong>Conclusion: </strong>PanOptix trifocal IOL implantation in cataract patients across different AL significantly enhances visual quality compared to bifocal IOLs, suggesting a strong case for its clinical adoption.</p>\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2024-07-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11301498/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.62347/FRJZ4885\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.62347/FRJZ4885","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
Analysis of visual quality improvement after implantation of PanOptix trifocal intraocular lens in cataract patients with different axial lengths.
Objective: To assess the visual quality, both subjective and objective, of cataract patients with varying axial lengths (AL) after PanOptix trifocal intraocular lens (IOL) implantation and investigated the lens tilt and its correlation with visual outcomes.
Methods: From July 2020 to June 2022, 70 patients (140 eyes) diagnosed with age-related cataracts and undergoing PanOptix implantation at Chongqing Eye and Vision Care Hospital, Aier Eye Hospital Group, were included. Patients were assigned to either the observation group (35 cases, 70 eyes with PanOptix trifocal IOL) or the control group (35 cases, 70 eyes with bifocal IOL). Patients were further subdivided based on AL into AL < 24 mm (observation group: 23 eyes; control group: 26 eyes) and AL ≥ 24 mm (observation group: 47 eyes; control group: 44 eyes). Postoperative follow-up lasted three months. Visual acuity (distant, intermediate, near), objective visual quality (Strehl ratio: SR, total eye modulation transfer function (MTF)), and visual aberrations were measured preoperatively and at 3 months post-operation.
Results: Postoperatively, all groups saw significant improvements in uncorrected distance visual acuity (UCDVA), uncorrected intermediate visual acuity (UCIVA), and uncorrected near visual acuity (UCNVA) compared to preoperative values (T0) (all P < 0.05). Notably, UCIVA was significantly better in the observation group than in the control group (P < 0.05). At three months (T1), reductions in total high-order aberration (tHOA), internal high-order aberration (iHOA), coma, and trefoil aberrations were observed in both groups compared to baseline, with more significant decreases in the observation group (all P < 0.05). Both SR and MTF cutoff showed marked improvement from T0 to T1, with the observation group experiencing greater enhancements (both P < 0.05). The defocus curve of the observation group showed a gentle slope between +0.5 D and -3.0 D, maintaining superior visual acuity compared to the control group (P < 0.05). Subjective visual quality scores at T1 were significantly higher than at T0 for both groups (P < 0.05), with patients in the observation group scoring higher than those in the control group across all AL categories (P < 0.05). Spearman correlation analysis indicated that the tilt after PanOptix trifocal IOL implantation was associated with tHOA (r = 0.273, P = 0.022), iHOA (r = 0.433, P < 0.001), Trefoil (r = 0.360, P = 0.002) and coma (r = 0.688, P < 0.001).
Conclusion: PanOptix trifocal IOL implantation in cataract patients across different AL significantly enhances visual quality compared to bifocal IOLs, suggesting a strong case for its clinical adoption.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.