{"title":"体外肺灌注过程中延长缺血时间与死亡率增加无关。","authors":"Doug A Gouchoe, Divyaam Satija, Ervin Y Cui, Ahmed Aly, Matthew C Henn, Kukbin Choi, David Nunley, Nahush A Mokadam, Asvin M Ganapathi, Bryan A Whitson","doi":"10.1111/aor.14820","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The purpose of this study was to identify the association of increasing ischemic times in recipients who receive lungs evaluated by ex vivo lung perfusion (EVLP) and their association with outcomes following lung transplantation.</p><p><strong>Methods: </strong>Lung transplant recipients who received an allograft evaluated by EVLP were identified from the United Network for Organ Sharing (UNOS) Database from 2016-2023. Recipients were stratified into three groups based on total ischemic time (TOT): short TOT (STOT, 0 to <7 h), medium TOT (MTOT, 7> to <14 h), and long TOT (LTOT, +14 h). The groups were assessed with comparative statistics and Kaplan-Meier methods. A Cox regression was created to determine the association of ischemic time in EVLP donors and long-term mortality.</p><p><strong>Results: </strong>Recipients in the LTOT group had significantly longer length of stay and post-operative extracorporeal membrane use at 72 h (p < 0.05 for both). Additionally, they had nonsignificant increases in rate of stroke (4.7%, p = 0.05) and primary graft dysfunction grade 3 (PGD3, 27.5%, p = 0.082). However, there was no significant difference in hospital mortality or mid-term survival (p > 0.05 for both). On multivariable analysis, ischemic time was not associated with increased mortality whereas increasing recipient age, preoperative ECMO use and donation after circulatory death donors were (p < 0.05 for all).</p><p><strong>Conclusions: </strong>If EVLP technology is available, under certain circumstances, surgeons should not be dissuaded from using an allograft with extended ischemic time.</p>","PeriodicalId":8450,"journal":{"name":"Artificial organs","volume":null,"pages":null},"PeriodicalIF":2.2000,"publicationDate":"2024-08-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Extended ischemic times during ex vivo lung perfusion is not associated with increased mortality.\",\"authors\":\"Doug A Gouchoe, Divyaam Satija, Ervin Y Cui, Ahmed Aly, Matthew C Henn, Kukbin Choi, David Nunley, Nahush A Mokadam, Asvin M Ganapathi, Bryan A Whitson\",\"doi\":\"10.1111/aor.14820\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>The purpose of this study was to identify the association of increasing ischemic times in recipients who receive lungs evaluated by ex vivo lung perfusion (EVLP) and their association with outcomes following lung transplantation.</p><p><strong>Methods: </strong>Lung transplant recipients who received an allograft evaluated by EVLP were identified from the United Network for Organ Sharing (UNOS) Database from 2016-2023. Recipients were stratified into three groups based on total ischemic time (TOT): short TOT (STOT, 0 to <7 h), medium TOT (MTOT, 7> to <14 h), and long TOT (LTOT, +14 h). The groups were assessed with comparative statistics and Kaplan-Meier methods. A Cox regression was created to determine the association of ischemic time in EVLP donors and long-term mortality.</p><p><strong>Results: </strong>Recipients in the LTOT group had significantly longer length of stay and post-operative extracorporeal membrane use at 72 h (p < 0.05 for both). Additionally, they had nonsignificant increases in rate of stroke (4.7%, p = 0.05) and primary graft dysfunction grade 3 (PGD3, 27.5%, p = 0.082). However, there was no significant difference in hospital mortality or mid-term survival (p > 0.05 for both). On multivariable analysis, ischemic time was not associated with increased mortality whereas increasing recipient age, preoperative ECMO use and donation after circulatory death donors were (p < 0.05 for all).</p><p><strong>Conclusions: </strong>If EVLP technology is available, under certain circumstances, surgeons should not be dissuaded from using an allograft with extended ischemic time.</p>\",\"PeriodicalId\":8450,\"journal\":{\"name\":\"Artificial organs\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.2000,\"publicationDate\":\"2024-08-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Artificial organs\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1111/aor.14820\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Artificial organs","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1111/aor.14820","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

背景:本研究旨在确定接受体外肺灌注(EVLP)评估的肺移植受者缺血时间延长与肺移植术后预后的关系:从器官共享联合网络(UNOS)2016-2023 年数据库中识别了接受过 EVLP 评估的同种异体肺移植受者。根据总缺血时间(TOT)将受者分为三组:短缺血时间组(STOT,0至结果)、长缺血时间组(LTOT,0至结果)和长缺血时间组(EVLP,0至结果):LTOT组受者的住院时间和术后72小时体外膜使用时间明显更长(均为P 0.05)。在多变量分析中,缺血时间与死亡率增加无关,而受者年龄增加、术前使用 ECMO 和循环死亡供体后捐献则与死亡率增加有关(P 结论:如果有 EVLP 技术,在某些情况下,外科医生不应该放弃使用延长缺血时间的同种异体移植物。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Extended ischemic times during ex vivo lung perfusion is not associated with increased mortality.

Background: The purpose of this study was to identify the association of increasing ischemic times in recipients who receive lungs evaluated by ex vivo lung perfusion (EVLP) and their association with outcomes following lung transplantation.

Methods: Lung transplant recipients who received an allograft evaluated by EVLP were identified from the United Network for Organ Sharing (UNOS) Database from 2016-2023. Recipients were stratified into three groups based on total ischemic time (TOT): short TOT (STOT, 0 to <7 h), medium TOT (MTOT, 7> to <14 h), and long TOT (LTOT, +14 h). The groups were assessed with comparative statistics and Kaplan-Meier methods. A Cox regression was created to determine the association of ischemic time in EVLP donors and long-term mortality.

Results: Recipients in the LTOT group had significantly longer length of stay and post-operative extracorporeal membrane use at 72 h (p < 0.05 for both). Additionally, they had nonsignificant increases in rate of stroke (4.7%, p = 0.05) and primary graft dysfunction grade 3 (PGD3, 27.5%, p = 0.082). However, there was no significant difference in hospital mortality or mid-term survival (p > 0.05 for both). On multivariable analysis, ischemic time was not associated with increased mortality whereas increasing recipient age, preoperative ECMO use and donation after circulatory death donors were (p < 0.05 for all).

Conclusions: If EVLP technology is available, under certain circumstances, surgeons should not be dissuaded from using an allograft with extended ischemic time.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Artificial organs
Artificial organs 工程技术-工程:生物医学
CiteScore
4.30
自引率
12.50%
发文量
303
审稿时长
4-8 weeks
期刊介绍: Artificial Organs is the official peer reviewed journal of The International Federation for Artificial Organs (Members of the Federation are: The American Society for Artificial Internal Organs, The European Society for Artificial Organs, and The Japanese Society for Artificial Organs), The International Faculty for Artificial Organs, the International Society for Rotary Blood Pumps, The International Society for Pediatric Mechanical Cardiopulmonary Support, and the Vienna International Workshop on Functional Electrical Stimulation. Artificial Organs publishes original research articles dealing with developments in artificial organs applications and treatment modalities and their clinical applications worldwide. Membership in the Societies listed above is not a prerequisite for publication. Articles are published without charge to the author except for color figures and excess page charges as noted.
期刊最新文献
Issue Information Cover Image Upcoming Meetings Development and validation of a questionnaire on bodily experience in VAD patients (BE-S). Single-center experience of extended brain-death donor heart preservation with the organ care system.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1