利用三维磁共振成像对外侧踝关节韧带附着位置进行内部和相互测量的可靠性。

IF 1.5 4区 医学 Q3 ORTHOPEDICS Journal of Orthopaedic Science Pub Date : 2024-08-19 DOI:10.1016/j.jos.2024.08.002
Yuriko Yoshimoto, Satoshi Yamaguchi, Seiji Kimura, Kaoru Kitsukawa, Koji Matsumoto, Yuki Shiko, Manato Horii, Shotaro Watanabe, Takahisa Sasho, Seiji Ohtori
{"title":"利用三维磁共振成像对外侧踝关节韧带附着位置进行内部和相互测量的可靠性。","authors":"Yuriko Yoshimoto, Satoshi Yamaguchi, Seiji Kimura, Kaoru Kitsukawa, Koji Matsumoto, Yuki Shiko, Manato Horii, Shotaro Watanabe, Takahisa Sasho, Seiji Ohtori","doi":"10.1016/j.jos.2024.08.002","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>We aimed to evaluate the intra- and interrater measurement reliability of the lateral ankle ligament attachment locations using three-dimensional magnetic resonance imaging.</p><p><strong>Methods: </strong>We analysed 54 participants with a mean age of 43 years who underwent three-dimensional ankle magnetic resonance imaging and had normal lateral ligaments. Bony landmarks of the distal fibula, talus, and calcaneus were identified in the reconstructed images. The centers of the anterior talofibular ligament and calcaneofibular ligament attachments were also identified. The distances between the landmarks and attachments were measured. Two raters performed the measurements twice, and intra- and interrater intraclass correlation coefficients were calculated.</p><p><strong>Results: </strong>The intrarater intraclass correlation coefficient values were between 0.71 and 0.96 for the anterior talofibular ligament attachment measurements and between 0.77 and 0.95 for the calcaneofibular ligament attachments. The interrater intraclass correlation coefficient was higher than 0.7, except for the distance between the anterior talofibular ligament superior bundle and fibular obscure tubercle. The fibular attachment of a single-bundle anterior talofibular ligament was located 13.3 mm from the inferior tip and 43% along the anterior edge of the distal fibula. The superior and inferior bundles of the double-bundle ligament were located at 43% and 23%, respectively. The calcaneofibular ligament fibular attachment was 5.5 mm from the inferior tip, at 16% along the anterior edge of the distal fibula.</p><p><strong>Conclusion: </strong>The measurements of anterior talofibular ligament and calcaneofibular ligament attachment locations identified on three-dimensional magnetic resonance imaging were sufficiently reliable. This measurement method provides in vivo anatomical data on the lateral ankle ligament anatomy.</p>","PeriodicalId":16939,"journal":{"name":"Journal of Orthopaedic Science","volume":" ","pages":""},"PeriodicalIF":1.5000,"publicationDate":"2024-08-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Intra- and interrater measurement reliability of lateral ankle ligament attachment locations using three-dimensional magnetic resonance imaging.\",\"authors\":\"Yuriko Yoshimoto, Satoshi Yamaguchi, Seiji Kimura, Kaoru Kitsukawa, Koji Matsumoto, Yuki Shiko, Manato Horii, Shotaro Watanabe, Takahisa Sasho, Seiji Ohtori\",\"doi\":\"10.1016/j.jos.2024.08.002\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>We aimed to evaluate the intra- and interrater measurement reliability of the lateral ankle ligament attachment locations using three-dimensional magnetic resonance imaging.</p><p><strong>Methods: </strong>We analysed 54 participants with a mean age of 43 years who underwent three-dimensional ankle magnetic resonance imaging and had normal lateral ligaments. Bony landmarks of the distal fibula, talus, and calcaneus were identified in the reconstructed images. The centers of the anterior talofibular ligament and calcaneofibular ligament attachments were also identified. The distances between the landmarks and attachments were measured. Two raters performed the measurements twice, and intra- and interrater intraclass correlation coefficients were calculated.</p><p><strong>Results: </strong>The intrarater intraclass correlation coefficient values were between 0.71 and 0.96 for the anterior talofibular ligament attachment measurements and between 0.77 and 0.95 for the calcaneofibular ligament attachments. The interrater intraclass correlation coefficient was higher than 0.7, except for the distance between the anterior talofibular ligament superior bundle and fibular obscure tubercle. The fibular attachment of a single-bundle anterior talofibular ligament was located 13.3 mm from the inferior tip and 43% along the anterior edge of the distal fibula. The superior and inferior bundles of the double-bundle ligament were located at 43% and 23%, respectively. The calcaneofibular ligament fibular attachment was 5.5 mm from the inferior tip, at 16% along the anterior edge of the distal fibula.</p><p><strong>Conclusion: </strong>The measurements of anterior talofibular ligament and calcaneofibular ligament attachment locations identified on three-dimensional magnetic resonance imaging were sufficiently reliable. This measurement method provides in vivo anatomical data on the lateral ankle ligament anatomy.</p>\",\"PeriodicalId\":16939,\"journal\":{\"name\":\"Journal of Orthopaedic Science\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2024-08-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Orthopaedic Science\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1016/j.jos.2024.08.002\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Orthopaedic Science","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.jos.2024.08.002","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

摘要

背景:我们的目的是利用三维磁共振成像评估外侧踝关节韧带附着位置的内部和相互测量可靠性:我们对 54 名平均年龄为 43 岁、接受过三维踝关节磁共振成像且外侧韧带正常的参与者进行了分析。在重建图像中确定了腓骨远端、距骨和小方骨的骨性地标。此外,还确定了距腓前韧带和小方腓韧带附着点的中心。测量地标和附着点之间的距离。两名评分员进行了两次测量,并计算了评分员内部和评分员之间的类内相关系数:结果:对距胫骨前韧带附着物的测量结果,评分者内部的类内相关系数在 0.71 至 0.96 之间;对方腓韧带附着物的测量结果,评分者内部的类内相关系数在 0.77 至 0.95 之间。除了距骨腓骨前韧带上束与腓骨不明显结节之间的距离外,其他测量的类间相关系数均高于 0.7。单束距骨前韧带的腓骨附着点距离下端13.3毫米,43%位于腓骨远端前缘。双束韧带的上束和下束分别位于43%和23%处。小腿腓骨韧带腓骨附着点距离下端5.5毫米,位于腓骨远端前缘的16%处:结论:通过三维磁共振成像确定的距腓前韧带和小方腓韧带附着位置的测量结果非常可靠。这种测量方法提供了外侧踝关节韧带解剖的活体解剖数据。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Intra- and interrater measurement reliability of lateral ankle ligament attachment locations using three-dimensional magnetic resonance imaging.

Background: We aimed to evaluate the intra- and interrater measurement reliability of the lateral ankle ligament attachment locations using three-dimensional magnetic resonance imaging.

Methods: We analysed 54 participants with a mean age of 43 years who underwent three-dimensional ankle magnetic resonance imaging and had normal lateral ligaments. Bony landmarks of the distal fibula, talus, and calcaneus were identified in the reconstructed images. The centers of the anterior talofibular ligament and calcaneofibular ligament attachments were also identified. The distances between the landmarks and attachments were measured. Two raters performed the measurements twice, and intra- and interrater intraclass correlation coefficients were calculated.

Results: The intrarater intraclass correlation coefficient values were between 0.71 and 0.96 for the anterior talofibular ligament attachment measurements and between 0.77 and 0.95 for the calcaneofibular ligament attachments. The interrater intraclass correlation coefficient was higher than 0.7, except for the distance between the anterior talofibular ligament superior bundle and fibular obscure tubercle. The fibular attachment of a single-bundle anterior talofibular ligament was located 13.3 mm from the inferior tip and 43% along the anterior edge of the distal fibula. The superior and inferior bundles of the double-bundle ligament were located at 43% and 23%, respectively. The calcaneofibular ligament fibular attachment was 5.5 mm from the inferior tip, at 16% along the anterior edge of the distal fibula.

Conclusion: The measurements of anterior talofibular ligament and calcaneofibular ligament attachment locations identified on three-dimensional magnetic resonance imaging were sufficiently reliable. This measurement method provides in vivo anatomical data on the lateral ankle ligament anatomy.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Orthopaedic Science
Journal of Orthopaedic Science 医学-整形外科
CiteScore
3.00
自引率
0.00%
发文量
290
审稿时长
90 days
期刊介绍: The Journal of Orthopaedic Science is the official peer-reviewed journal of the Japanese Orthopaedic Association. The journal publishes the latest researches and topical debates in all fields of clinical and experimental orthopaedics, including musculoskeletal medicine, sports medicine, locomotive syndrome, trauma, paediatrics, oncology and biomaterials, as well as basic researches.
期刊最新文献
Validation of the Japanese version of the scoliosis research society-30 questionnaire for adult patients with spinal deformity. Prevalence and associated factors for primary osteoarthritis of the thumb carpometacarpal joint in the general elderly population: A cohort survey randomly sampled from a basic resident registry of a small rural town in Japan. Radiological features of the carpometacarpal joint in hamate body fracture on anteroposterior hand X-ray image. Clinical characteristics and results after conservative treatment or interfascicular neurolysis of 100 limbs with spontaneous anterior interosseous nerve palsy: A prospective Japanese multicenter study. Minimal clinically important difference in the Japanese Orthopedic Association Score and shoulder 36 after arthroscopic rotator cuff repair in a Japanese population: A retrospective cohort study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1