腹腔镜袖状胃切除术后不同血管密封装置的术后出血率和出血位置比较

Dylan Cuva, Julia Park, Patricia Chui, Jeffrey Lipman, Peter Einersen, John K Saunders, Manish Parikh
{"title":"腹腔镜袖状胃切除术后不同血管密封装置的术后出血率和出血位置比较","authors":"Dylan Cuva, Julia Park, Patricia Chui, Jeffrey Lipman, Peter Einersen, John K Saunders, Manish Parikh","doi":"10.1089/lap.2024.0082","DOIUrl":null,"url":null,"abstract":"<p><p><b><i>Background:</i></b> Laparoscopic sleeve gastrectomy (SG) is a commonly performed bariatric procedure. At our institution, two vessel sealing devices, Thunderbeat<sup>®</sup> (Olympus) and Maryland LigaSure™ (Covidien) are utilized for intraoperative dissection. <b><i>Methods:</i></b> A retrospective review of all patients who underwent primary SG from July 2013 through August 2022 was performed to evaluate postoperative bleeding (POB) rates between the two devices. The primary outcome measured was POB as defined by the Metabolic and Bariatric Surgery Accreditation and Quality Improvement Program (MBSAQIP), with secondary outcomes including reoperation, source of bleed, and overall safety. <b><i>Results:</i></b> A total of 8157 underwent SG. Average BMI and age were 43.2 kg/m<sup>2</sup> and 37.1 years, respectively. A total of 6600 (80.9%) were female. Thunderbeat<sup>®</sup> was utilized in 5143 (63%) cases and Maryland LigaSure™ was used in 3014 (37%) cases. There was no significant difference in overall bleeding between the Thunderbeat<sup>®</sup> (18/5143, .35%) and the Maryland LigaSure™ (19/3014, .63%; <i>P</i> = .0689). However, there was a difference noted when comparing reoperation for bleeding between Thunderbeat<sup>®</sup> (9/5143, .17%) and Maryland LigaSure™ (13/3014, .43%; <i>P</i> = .0291). Furthermore, the location of bleeding in the reoperations was more common from the cut edge of the mesentery compared to the staple line with the Maryland LigaSure™ versus the Thunderbeat<sup>®</sup> (<i>P</i> = .038). <b><i>Conclusions:</i></b> The Thunderbeat<sup>®</sup> device is comparatively more hemostatic than the Maryland LigaSure™ for SG. The location of postoperative bleed may be related to vessel sealing devices used.</p>","PeriodicalId":50166,"journal":{"name":"Journal of Laparoendoscopic & Advanced Surgical Techniques","volume":" ","pages":""},"PeriodicalIF":1.1000,"publicationDate":"2024-08-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparison of Postoperative Bleed Rates and Location of Bleed Between Vessel Sealing Devices after Laparoscopic Sleeve Gastrectomy.\",\"authors\":\"Dylan Cuva, Julia Park, Patricia Chui, Jeffrey Lipman, Peter Einersen, John K Saunders, Manish Parikh\",\"doi\":\"10.1089/lap.2024.0082\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b><i>Background:</i></b> Laparoscopic sleeve gastrectomy (SG) is a commonly performed bariatric procedure. At our institution, two vessel sealing devices, Thunderbeat<sup>®</sup> (Olympus) and Maryland LigaSure™ (Covidien) are utilized for intraoperative dissection. <b><i>Methods:</i></b> A retrospective review of all patients who underwent primary SG from July 2013 through August 2022 was performed to evaluate postoperative bleeding (POB) rates between the two devices. The primary outcome measured was POB as defined by the Metabolic and Bariatric Surgery Accreditation and Quality Improvement Program (MBSAQIP), with secondary outcomes including reoperation, source of bleed, and overall safety. <b><i>Results:</i></b> A total of 8157 underwent SG. Average BMI and age were 43.2 kg/m<sup>2</sup> and 37.1 years, respectively. A total of 6600 (80.9%) were female. Thunderbeat<sup>®</sup> was utilized in 5143 (63%) cases and Maryland LigaSure™ was used in 3014 (37%) cases. There was no significant difference in overall bleeding between the Thunderbeat<sup>®</sup> (18/5143, .35%) and the Maryland LigaSure™ (19/3014, .63%; <i>P</i> = .0689). However, there was a difference noted when comparing reoperation for bleeding between Thunderbeat<sup>®</sup> (9/5143, .17%) and Maryland LigaSure™ (13/3014, .43%; <i>P</i> = .0291). Furthermore, the location of bleeding in the reoperations was more common from the cut edge of the mesentery compared to the staple line with the Maryland LigaSure™ versus the Thunderbeat<sup>®</sup> (<i>P</i> = .038). <b><i>Conclusions:</i></b> The Thunderbeat<sup>®</sup> device is comparatively more hemostatic than the Maryland LigaSure™ for SG. The location of postoperative bleed may be related to vessel sealing devices used.</p>\",\"PeriodicalId\":50166,\"journal\":{\"name\":\"Journal of Laparoendoscopic & Advanced Surgical Techniques\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2024-08-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Laparoendoscopic & Advanced Surgical Techniques\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1089/lap.2024.0082\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"SURGERY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Laparoendoscopic & Advanced Surgical Techniques","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1089/lap.2024.0082","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

摘要

背景:腹腔镜袖带胃切除术(SG)是一种常用的减肥手术。在本院,Thunderbeat®(奥林巴斯)和Maryland LigaSure™(Covidien)两种血管密封装置被用于术中剥离。方法:对 2013 年 7 月至 2022 年 8 月期间接受初级 SG 的所有患者进行回顾性审查,以评估两种装置的术后出血率 (POB)。测量的主要结果是代谢与减肥手术认证和质量改进计划(MBSAQIP)定义的POB,次要结果包括再次手术、出血来源和总体安全性。结果:共有 8157 人接受了 SG 手术。平均体重指数和年龄分别为 43.2 kg/m2 和 37.1 岁。共有 6600 人(80.9%)为女性。5143 例(63%)使用了 Thunderbeat®,3014 例(37%)使用了 Maryland LigaSure™。Thunderbeat®(18/5143,0.35%)和Maryland LigaSure™(19/3014,0.63%;P = 0.0689)的总体出血量没有明显差异。然而,在比较 Thunderbeat® (9/5143,0.17%)和 Maryland LigaSure™ (13/3014,0.43%;P = 0.0291)之间因出血而再次手术的情况时,发现两者之间存在差异。此外,与 Thunderbeat® 相比,马里兰 LigaSure™ 和 Thunderbeat® 再手术的出血位置更常见于系膜切缘,而不是缝合线(P = .038)。结论:就 SG 而言,Thunderbeat® 设备比 Maryland LigaSure™ 止血效果更好。术后出血的位置可能与使用的血管密封装置有关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Comparison of Postoperative Bleed Rates and Location of Bleed Between Vessel Sealing Devices after Laparoscopic Sleeve Gastrectomy.

Background: Laparoscopic sleeve gastrectomy (SG) is a commonly performed bariatric procedure. At our institution, two vessel sealing devices, Thunderbeat® (Olympus) and Maryland LigaSure™ (Covidien) are utilized for intraoperative dissection. Methods: A retrospective review of all patients who underwent primary SG from July 2013 through August 2022 was performed to evaluate postoperative bleeding (POB) rates between the two devices. The primary outcome measured was POB as defined by the Metabolic and Bariatric Surgery Accreditation and Quality Improvement Program (MBSAQIP), with secondary outcomes including reoperation, source of bleed, and overall safety. Results: A total of 8157 underwent SG. Average BMI and age were 43.2 kg/m2 and 37.1 years, respectively. A total of 6600 (80.9%) were female. Thunderbeat® was utilized in 5143 (63%) cases and Maryland LigaSure™ was used in 3014 (37%) cases. There was no significant difference in overall bleeding between the Thunderbeat® (18/5143, .35%) and the Maryland LigaSure™ (19/3014, .63%; P = .0689). However, there was a difference noted when comparing reoperation for bleeding between Thunderbeat® (9/5143, .17%) and Maryland LigaSure™ (13/3014, .43%; P = .0291). Furthermore, the location of bleeding in the reoperations was more common from the cut edge of the mesentery compared to the staple line with the Maryland LigaSure™ versus the Thunderbeat® (P = .038). Conclusions: The Thunderbeat® device is comparatively more hemostatic than the Maryland LigaSure™ for SG. The location of postoperative bleed may be related to vessel sealing devices used.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.90
自引率
0.00%
发文量
163
审稿时长
3 months
期刊介绍: Journal of Laparoendoscopic & Advanced Surgical Techniques (JLAST) is the leading international peer-reviewed journal for practicing surgeons who want to keep up with the latest thinking and advanced surgical technologies in laparoscopy, endoscopy, NOTES, and robotics. The Journal is ideally suited to surgeons who are early adopters of new technology and techniques. Recognizing that many new technologies and techniques have significant overlap with several surgical specialties, JLAST is the first journal to focus on these topics both in general and pediatric surgery, and includes other surgical subspecialties such as: urology, gynecologic surgery, thoracic surgery, and more.
期刊最新文献
Application of Intraoperative Ultrasound in Laparoscopic Liver Resection with Pringle Maneuver: A Comparative Study with the Pringle Maneuver. Short-Term Efficacy of LCBDE+LC Versus ERCP/EST+LC in the Treatment of Cholelithiasis Combined with Common Bile Duct Stones: A Retrospective Cohort Study. Evaluation of Surgical Results and Effectiveness of Laparoscopic Transabdominal Preperitoneal and Laparoscopic Totally Extraperitoneal Approaches in Bilateral Inguinal Hernia Repair: A Randomized Analysis. Is Endoscopic Resection Essential for Patients with Type 1 Gastric Neuroendocrine Tumor? Is It Necessary to Endoscopically Evaluate the Anastomosis in Robotic or Laparoscopic Surgical Procedures for Colorectal Cancer?
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1