在没有下腔静脉通路的患者中进行导管消融的三维绘图和高级方法。

IF 1.7 4区 医学 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS Pace-Pacing and Clinical Electrophysiology Pub Date : 2024-11-01 Epub Date: 2024-08-27 DOI:10.1111/pace.15047
Chu-Yu Hsu, Shih-Lin Chang, Yenn-Jiang Lin, Li-We Lo, Yu-Feng Hu, Fa-Po Chung, Chin-Yu Lin, Ting-Yung Chang, Chieh-Mao Chuang, Ming-Jen Kou, Wei-Tso Chen, Chheng Chhay, Pei-Heng Kao, Ahliah E Ibrahim, Wei-Shiang Lin, Shih-Ann Chen
{"title":"在没有下腔静脉通路的患者中进行导管消融的三维绘图和高级方法。","authors":"Chu-Yu Hsu, Shih-Lin Chang, Yenn-Jiang Lin, Li-We Lo, Yu-Feng Hu, Fa-Po Chung, Chin-Yu Lin, Ting-Yung Chang, Chieh-Mao Chuang, Ming-Jen Kou, Wei-Tso Chen, Chheng Chhay, Pei-Heng Kao, Ahliah E Ibrahim, Wei-Shiang Lin, Shih-Ann Chen","doi":"10.1111/pace.15047","DOIUrl":null,"url":null,"abstract":"<p><p>Catheter ablation for tachyarrhythmia via superior approach has been used in patients without possible inferior vena cava access such as in cases of venous occlusion or complex anomaly. Difficulty in catheter manipulation, instability, number of required vascular access, and radiation exposure of operator had been described in the procedure. Application of three-dimensional (3-D) mapping system in catheter ablation via superior approach could navigate the guiding catheter and provide more precise ablation. We reported four cases receiving catheter ablation due to atrioventricular nodal reentry tachycardia, atrial fibrillation, and right ventricular arrhythmia via superior approach facilitated by 3-D mapping system with fewer vascular access and catheters.</p>","PeriodicalId":54653,"journal":{"name":"Pace-Pacing and Clinical Electrophysiology","volume":null,"pages":null},"PeriodicalIF":1.7000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Three-dimensional mapping and superior approach for catheter ablation in patients without inferior vena cava access.\",\"authors\":\"Chu-Yu Hsu, Shih-Lin Chang, Yenn-Jiang Lin, Li-We Lo, Yu-Feng Hu, Fa-Po Chung, Chin-Yu Lin, Ting-Yung Chang, Chieh-Mao Chuang, Ming-Jen Kou, Wei-Tso Chen, Chheng Chhay, Pei-Heng Kao, Ahliah E Ibrahim, Wei-Shiang Lin, Shih-Ann Chen\",\"doi\":\"10.1111/pace.15047\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Catheter ablation for tachyarrhythmia via superior approach has been used in patients without possible inferior vena cava access such as in cases of venous occlusion or complex anomaly. Difficulty in catheter manipulation, instability, number of required vascular access, and radiation exposure of operator had been described in the procedure. Application of three-dimensional (3-D) mapping system in catheter ablation via superior approach could navigate the guiding catheter and provide more precise ablation. We reported four cases receiving catheter ablation due to atrioventricular nodal reentry tachycardia, atrial fibrillation, and right ventricular arrhythmia via superior approach facilitated by 3-D mapping system with fewer vascular access and catheters.</p>\",\"PeriodicalId\":54653,\"journal\":{\"name\":\"Pace-Pacing and Clinical Electrophysiology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2024-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Pace-Pacing and Clinical Electrophysiology\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1111/pace.15047\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/8/27 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pace-Pacing and Clinical Electrophysiology","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1111/pace.15047","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/27 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

导管消融术通过上腔途径治疗快速性心律失常,曾用于无法进入下腔静脉的患者,如静脉闭塞或复杂异常的病例。该方法存在导管操作困难、不稳定性、所需血管通路数量和操作者辐射暴露等问题。应用三维(3-D)映射系统通过上腔途径进行导管消融可以为引导导管导航,并提供更精确的消融。我们报告了四例因房室结返跳性心动过速、心房颤动和右室心律失常而接受导管消融术的病例,这些病例在三维映射系统的帮助下,通过上腔途径进行消融,减少了血管通路和导管。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Three-dimensional mapping and superior approach for catheter ablation in patients without inferior vena cava access.

Catheter ablation for tachyarrhythmia via superior approach has been used in patients without possible inferior vena cava access such as in cases of venous occlusion or complex anomaly. Difficulty in catheter manipulation, instability, number of required vascular access, and radiation exposure of operator had been described in the procedure. Application of three-dimensional (3-D) mapping system in catheter ablation via superior approach could navigate the guiding catheter and provide more precise ablation. We reported four cases receiving catheter ablation due to atrioventricular nodal reentry tachycardia, atrial fibrillation, and right ventricular arrhythmia via superior approach facilitated by 3-D mapping system with fewer vascular access and catheters.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Pace-Pacing and Clinical Electrophysiology
Pace-Pacing and Clinical Electrophysiology 医学-工程:生物医学
CiteScore
2.70
自引率
5.60%
发文量
209
审稿时长
2-4 weeks
期刊介绍: Pacing and Clinical Electrophysiology (PACE) is the foremost peer-reviewed journal in the field of pacing and implantable cardioversion defibrillation, publishing over 50% of all English language articles in its field, featuring original, review, and didactic papers, and case reports related to daily practice. Articles also include editorials, book reviews, Musings on humane topics relevant to medical practice, electrophysiology (EP) rounds, device rounds, and information concerning the quality of devices used in the practice of the specialty.
期刊最新文献
Coronary Spasm Due to Pulsed Field Ablation: A State-of-the-Art Review. Recalled But Responsive: Easier Extraction of Recalled Leads. Vein of Marshall Ethanol Infusion: Beware the Left Atrial Appendage Isolation. Changes in QRS morphology during antidromic atrioventricular reentrant tachycardia. Exercise-induced type 1 Brugada pattern in a child.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1