聚丙烯与不锈钢丝缝合:腹股沟疝修补术后的短期复发率,对1120名患者进行的非劣效分析。病例对照研究。

IF 2.6 2区 医学 Q1 SURGERY Hernia Pub Date : 2024-12-01 Epub Date: 2024-08-29 DOI:10.1007/s10029-024-03110-z
Christoph Paasch, Marguerite Mainprize, Richard Hunger, Fernando A C Spencer Netto
{"title":"聚丙烯与不锈钢丝缝合:腹股沟疝修补术后的短期复发率,对1120名患者进行的非劣效分析。病例对照研究。","authors":"Christoph Paasch, Marguerite Mainprize, Richard Hunger, Fernando A C Spencer Netto","doi":"10.1007/s10029-024-03110-z","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Polypropylene material is commonly used for posterior wall reconstruction in hernia repair, in contrast with the classically described stainless-steel wire used at Shouldice Hospital. This study was conducted to evaluate possible differences in Shouldice Repair outcomes using polypropylene or stainless-steel wire sutures.</p><p><strong>Methods: </strong>A prospective follow-up of consecutive patients who underwent elective unilateral Shouldice primary inguinal hernia repair at Shouldice Hospital between December 6, 2021, and September 1, 2022, was conducted. Data was collected from follow-up telephone calls as well as manually reviewing patient's charts. The primary objective was to determine whether the use of polypropylene was non-inferior to the use of stainless-steel wire, regarding the recurrence rate reported by the patients with a minimum follow-up of 1 year after Shouldice primary inguinal hernia repair.</p><p><strong>Results: </strong>A total of 1120 patients were contacted by telephone (polypropylene: 560; stainless-steel wire: 560). The median follow-up period was 16 months (interquartile range: 15-18). In 22 (1.96%) cases a surgical site infection was diagnosed. There was a total of 18 recurrences reported by the patients (1.6%). There was no statistical difference between the groups (polypropylene: 7 (1.25%) vs. stainless steel wire: 11 (1.96%), p > 0.05) for the recurrence rate.</p><p><strong>Conclusion: </strong>The use of polypropylene is non-inferior to the use of stainless-steel wire regarding recurrence rate at a median follow-up period of 16 months after elective unilateral Shouldice primary inguinal hernia repair. This finding may encourage other centers where stainless-steel wire is not easily available to perform the Shouldice Repair.</p>","PeriodicalId":13168,"journal":{"name":"Hernia","volume":null,"pages":null},"PeriodicalIF":2.6000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11530496/pdf/","citationCount":"0","resultStr":"{\"title\":\"Polypropylene vs. stainless-steel wire suture: short-term recurrence rate after shouldice primary inguinal hernia repair, a non-inferior analysis among 1120 patients. A case-control study.\",\"authors\":\"Christoph Paasch, Marguerite Mainprize, Richard Hunger, Fernando A C Spencer Netto\",\"doi\":\"10.1007/s10029-024-03110-z\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>Polypropylene material is commonly used for posterior wall reconstruction in hernia repair, in contrast with the classically described stainless-steel wire used at Shouldice Hospital. This study was conducted to evaluate possible differences in Shouldice Repair outcomes using polypropylene or stainless-steel wire sutures.</p><p><strong>Methods: </strong>A prospective follow-up of consecutive patients who underwent elective unilateral Shouldice primary inguinal hernia repair at Shouldice Hospital between December 6, 2021, and September 1, 2022, was conducted. Data was collected from follow-up telephone calls as well as manually reviewing patient's charts. The primary objective was to determine whether the use of polypropylene was non-inferior to the use of stainless-steel wire, regarding the recurrence rate reported by the patients with a minimum follow-up of 1 year after Shouldice primary inguinal hernia repair.</p><p><strong>Results: </strong>A total of 1120 patients were contacted by telephone (polypropylene: 560; stainless-steel wire: 560). The median follow-up period was 16 months (interquartile range: 15-18). In 22 (1.96%) cases a surgical site infection was diagnosed. There was a total of 18 recurrences reported by the patients (1.6%). There was no statistical difference between the groups (polypropylene: 7 (1.25%) vs. stainless steel wire: 11 (1.96%), p > 0.05) for the recurrence rate.</p><p><strong>Conclusion: </strong>The use of polypropylene is non-inferior to the use of stainless-steel wire regarding recurrence rate at a median follow-up period of 16 months after elective unilateral Shouldice primary inguinal hernia repair. This finding may encourage other centers where stainless-steel wire is not easily available to perform the Shouldice Repair.</p>\",\"PeriodicalId\":13168,\"journal\":{\"name\":\"Hernia\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2024-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11530496/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Hernia\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s10029-024-03110-z\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/8/29 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"SURGERY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Hernia","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s10029-024-03110-z","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/29 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

摘要

简介在疝修补术中,聚丙烯材料通常用于后壁重建,这与 Shouldice 医院使用的经典不锈钢丝形成鲜明对比。本研究旨在评估使用聚丙烯缝合线或不锈钢丝缝合线进行 Shouldice 修补术的结果可能存在的差异:对 2021 年 12 月 6 日至 2022 年 9 月 1 日期间在 Shouldice 医院接受选择性单侧 Shouldice 腹股沟原发性疝修补术的连续患者进行了前瞻性随访。数据是通过随访电话和人工查看患者病历收集的。主要目的是确定在应氏腹股沟疝初次修复术后至少随访一年的患者报告的复发率方面,使用聚丙烯是否不劣于使用不锈钢丝:共通过电话联系了 1120 名患者(聚丙烯:560 人;不锈钢丝:560 人)。随访时间中位数为 16 个月(四分位数间距:15-18)。22例(1.96%)患者被诊断为手术部位感染。患者共报告了 18 例复发(1.6%)。各组之间没有统计学差异(聚丙烯线:7(1.25%)对不锈钢线:11(1.96%),聚丙烯线:1.25%对不锈钢线:1.96%):结论:结论:在选择性单侧肩胛原发性腹股沟疝修补术后 16 个月的中位随访期内,就复发率而言,使用聚丙烯丝并不比使用不锈钢丝差。这一发现可能会鼓励其他不容易获得不锈钢丝的中心进行肩股疝修补术。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Polypropylene vs. stainless-steel wire suture: short-term recurrence rate after shouldice primary inguinal hernia repair, a non-inferior analysis among 1120 patients. A case-control study.

Introduction: Polypropylene material is commonly used for posterior wall reconstruction in hernia repair, in contrast with the classically described stainless-steel wire used at Shouldice Hospital. This study was conducted to evaluate possible differences in Shouldice Repair outcomes using polypropylene or stainless-steel wire sutures.

Methods: A prospective follow-up of consecutive patients who underwent elective unilateral Shouldice primary inguinal hernia repair at Shouldice Hospital between December 6, 2021, and September 1, 2022, was conducted. Data was collected from follow-up telephone calls as well as manually reviewing patient's charts. The primary objective was to determine whether the use of polypropylene was non-inferior to the use of stainless-steel wire, regarding the recurrence rate reported by the patients with a minimum follow-up of 1 year after Shouldice primary inguinal hernia repair.

Results: A total of 1120 patients were contacted by telephone (polypropylene: 560; stainless-steel wire: 560). The median follow-up period was 16 months (interquartile range: 15-18). In 22 (1.96%) cases a surgical site infection was diagnosed. There was a total of 18 recurrences reported by the patients (1.6%). There was no statistical difference between the groups (polypropylene: 7 (1.25%) vs. stainless steel wire: 11 (1.96%), p > 0.05) for the recurrence rate.

Conclusion: The use of polypropylene is non-inferior to the use of stainless-steel wire regarding recurrence rate at a median follow-up period of 16 months after elective unilateral Shouldice primary inguinal hernia repair. This finding may encourage other centers where stainless-steel wire is not easily available to perform the Shouldice Repair.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Hernia
Hernia SURGERY-
CiteScore
4.90
自引率
26.10%
发文量
171
审稿时长
4-8 weeks
期刊介绍: Hernia was founded in 1997 by Jean P. Chevrel with the purpose of promoting clinical studies and basic research as they apply to groin hernias and the abdominal wall . Since that time, a true revolution in the field of hernia studies has transformed the field from a ”simple” disease to one that is very specialized. While the majority of surgeries for primary inguinal and abdominal wall hernia are performed in hospitals worldwide, complex situations such as multi recurrences, complications, abdominal wall reconstructions and others are being studied and treated in specialist centers. As a result, major institutions and societies are creating specific parameters and criteria to better address the complexities of hernia surgery. Hernia is a journal written by surgeons who have made abdominal wall surgery their specific field of interest, but we will consider publishing content from any surgeon who wishes to improve the science of this field. The Journal aims to ensure that hernia surgery is safer and easier for surgeons as well as patients, and provides a forum to all surgeons in the exchange of new ideas, results, and important research that is the basis of professional activity.
期刊最新文献
Correction to: Analysis of hospitalization costs in adult inguinal hernia: based on quantile regression model. Correction to: Mesh versus suture for elective primary umbilical hernia open repair: a systematic review and meta-analysis. Artificial intelligence (AI), the metaverse and remote learning: simplifications or illusions? Hybrid intraperitoneal onlay mesh repair for incisional hernias: a systematic review and meta-analysis. Mesh versus suture for elective primary umbilical hernia open repair: a systematic review and meta-analysis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1