{"title":"氰化氢(HCN)干涉仪测量近太空高超音速飞行器等离子体电磁科学实验研究装置(ERAES)的首批成果。","authors":"J B Zhang, H Q Liu, Y Zhang, X C Wei, J X Xie, S X Wang, H Lian, Y X Jie, L Q Hu","doi":"10.1063/5.0215704","DOIUrl":null,"url":null,"abstract":"<p><p>The formation of a plasma sheath on the surface of spacecraft or satellites during high-speed atmospheric entry is a significant factor that affects communication and radar detection. Experimental research apparatus for electromagnetic science can simulate this plasma sheath and study the interaction mechanisms between electromagnetic waves and plasma sheaths. Electron density is a crucial parameter for this research. Therefore, in this paper, a HCN heterodyne interferometer has been designed to measure the electron densities of the device, which range from 1 × 109 to 3 × 1013 cm-3 and the pressure ranges from 50 to 1500 Pa. The light source is a HCN laser with a wavelength of 337 µm, which exhibits higher spatial resolution compared to microwave interferometers. The interferometer is configured as a Mach-Zehnder interferometer, which generates an intermediate frequency through the Doppler shift achieved by a rotating grating. The spatial and temporal resolution of the HCN interferometry reach ∼14 mm and 100 µs, respectively. Antenna-coupled ALGaN/GaN-HEMT detectors have been utilized, as they possess higher sensitivity-with a typical reduction factor responsivity of around 900 V/W-than VDI planar-diode Integrated Conical Horn Fundamental Mixers in HCN interferometry. Recently, the initial results of the HCN interferometer designed for ERAES have been obtained during an experimental campaign, demonstrating a phase resolution of up to 0.04π.</p>","PeriodicalId":21111,"journal":{"name":"Review of Scientific Instruments","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The first results of the hydrogen cyanide (HCN) interferometer measuring experimental research apparatus for electromagnetic science (ERAES) for hypersonic vehicle plasma in near space.\",\"authors\":\"J B Zhang, H Q Liu, Y Zhang, X C Wei, J X Xie, S X Wang, H Lian, Y X Jie, L Q Hu\",\"doi\":\"10.1063/5.0215704\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The formation of a plasma sheath on the surface of spacecraft or satellites during high-speed atmospheric entry is a significant factor that affects communication and radar detection. Experimental research apparatus for electromagnetic science can simulate this plasma sheath and study the interaction mechanisms between electromagnetic waves and plasma sheaths. Electron density is a crucial parameter for this research. Therefore, in this paper, a HCN heterodyne interferometer has been designed to measure the electron densities of the device, which range from 1 × 109 to 3 × 1013 cm-3 and the pressure ranges from 50 to 1500 Pa. The light source is a HCN laser with a wavelength of 337 µm, which exhibits higher spatial resolution compared to microwave interferometers. The interferometer is configured as a Mach-Zehnder interferometer, which generates an intermediate frequency through the Doppler shift achieved by a rotating grating. The spatial and temporal resolution of the HCN interferometry reach ∼14 mm and 100 µs, respectively. Antenna-coupled ALGaN/GaN-HEMT detectors have been utilized, as they possess higher sensitivity-with a typical reduction factor responsivity of around 900 V/W-than VDI planar-diode Integrated Conical Horn Fundamental Mixers in HCN interferometry. Recently, the initial results of the HCN interferometer designed for ERAES have been obtained during an experimental campaign, demonstrating a phase resolution of up to 0.04π.</p>\",\"PeriodicalId\":21111,\"journal\":{\"name\":\"Review of Scientific Instruments\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2024-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Review of Scientific Instruments\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1063/5.0215704\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"INSTRUMENTS & INSTRUMENTATION\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Review of Scientific Instruments","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1063/5.0215704","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0

摘要

航天器或卫星在高速进入大气层时,其表面会形成等离子鞘,这是影响通信和雷达探测的一个重要因素。电磁科学实验研究设备可以模拟这种等离子鞘,研究电磁波与等离子鞘之间的相互作用机制。电子密度是这一研究的关键参数。因此,本文设计了一个 HCN 外差干涉仪来测量该装置的电子密度,其范围为 1 × 109 至 3 × 1013 cm-3,压力范围为 50 至 1500 Pa。光源是波长为 337 微米的 HCN 激光器,与微波干涉仪相比,具有更高的空间分辨率。该干涉仪配置为马赫-泽恩德干涉仪,通过旋转光栅实现的多普勒频移产生中间频率。HCN 干涉仪的空间和时间分辨率分别达到 14 毫米和 100 微秒。在 HCN 干涉测量中,天线耦合 ALGaN/GaN-HEMT 探测器比 VDI 平面二极管集成锥形喇叭基频混频器具有更高的灵敏度(典型的降低系数响应率约为 900 V/W)。最近,为ERAES设计的HCN干涉仪在一次实验活动中取得了初步成果,显示出高达0.04π的相位分辨率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The first results of the hydrogen cyanide (HCN) interferometer measuring experimental research apparatus for electromagnetic science (ERAES) for hypersonic vehicle plasma in near space.

The formation of a plasma sheath on the surface of spacecraft or satellites during high-speed atmospheric entry is a significant factor that affects communication and radar detection. Experimental research apparatus for electromagnetic science can simulate this plasma sheath and study the interaction mechanisms between electromagnetic waves and plasma sheaths. Electron density is a crucial parameter for this research. Therefore, in this paper, a HCN heterodyne interferometer has been designed to measure the electron densities of the device, which range from 1 × 109 to 3 × 1013 cm-3 and the pressure ranges from 50 to 1500 Pa. The light source is a HCN laser with a wavelength of 337 µm, which exhibits higher spatial resolution compared to microwave interferometers. The interferometer is configured as a Mach-Zehnder interferometer, which generates an intermediate frequency through the Doppler shift achieved by a rotating grating. The spatial and temporal resolution of the HCN interferometry reach ∼14 mm and 100 µs, respectively. Antenna-coupled ALGaN/GaN-HEMT detectors have been utilized, as they possess higher sensitivity-with a typical reduction factor responsivity of around 900 V/W-than VDI planar-diode Integrated Conical Horn Fundamental Mixers in HCN interferometry. Recently, the initial results of the HCN interferometer designed for ERAES have been obtained during an experimental campaign, demonstrating a phase resolution of up to 0.04π.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Review of Scientific Instruments
Review of Scientific Instruments 工程技术-物理:应用
CiteScore
3.00
自引率
12.50%
发文量
758
审稿时长
2.6 months
期刊介绍: Review of Scientific Instruments, is committed to the publication of advances in scientific instruments, apparatuses, and techniques. RSI seeks to meet the needs of engineers and scientists in physics, chemistry, and the life sciences.
期刊最新文献
A liquid metal diffusion measurement technique integrating the x-ray radiography and multi-slice sliding cell. Classification of the L-, H-mode, and plasma-free state: Convolutional neural networks and variational autoencoders on the edge reflectometer for KSTAR. Design of a gamma threshold detector based on the bubble chamber for high-flux gamma beams. Development and construction of a cost-effective non-contact instrument for measuring the dielectric constant of liquids. Development of a compact bolometer camera concept for investigation of radiation asymmetries at Wendelstein 7-X.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1