用于灵敏检测溶液中重金属的增强型等离子体光栅诱导击穿光谱仪

IF 3.2 2区 化学 Q1 SPECTROSCOPY Spectrochimica Acta Part B: Atomic Spectroscopy Pub Date : 2024-08-17 DOI:10.1016/j.sab.2024.107019
Fangfang Li , Mengyun Hu , Yu Qiao , Shupeng Xu , Enlai Wan , Heping Zeng
{"title":"用于灵敏检测溶液中重金属的增强型等离子体光栅诱导击穿光谱仪","authors":"Fangfang Li ,&nbsp;Mengyun Hu ,&nbsp;Yu Qiao ,&nbsp;Shupeng Xu ,&nbsp;Enlai Wan ,&nbsp;Heping Zeng","doi":"10.1016/j.sab.2024.107019","DOIUrl":null,"url":null,"abstract":"<div><p>Plasma grating-induced breakdown spectroscopy (GIBS) has gained notable attention for its capacity in trace metal element detection. This study examined the utilization of plasma grating to create micropores and nanoparticles on a Si sample surface and explored their impact on GIBS. We found that the presence of these features resulted in a significant 2.4-fold enhancement in the spectral intensity of the Si plasma at a laser energy of 2.7 mJ, with micropores structures and nanoparticles promoting the plasma excitation. Furthermore, the effect of micropores structures and nanoparticles on the spectral intensities of Cr and Cd elements in water was investigated. Significantly, the spectral line intensity of heavy metal Cr and Cd in the etched area was about 4.5 and 2.6 times that of the unetched area, and the detection limit for trace levels of Cr and Cd in water was determined to be 6.40 mg/L and 75.0 mg/L, respectively. These findings highlight the promising potential of the enhanced GIBS as a more sensitive method for detecting trace metal elements in water.</p></div>","PeriodicalId":21890,"journal":{"name":"Spectrochimica Acta Part B: Atomic Spectroscopy","volume":"220 ","pages":"Article 107019"},"PeriodicalIF":3.2000,"publicationDate":"2024-08-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Enhanced plasma grating-induced breakdown spectroscopy for sensitive detection of heavy metal in solution\",\"authors\":\"Fangfang Li ,&nbsp;Mengyun Hu ,&nbsp;Yu Qiao ,&nbsp;Shupeng Xu ,&nbsp;Enlai Wan ,&nbsp;Heping Zeng\",\"doi\":\"10.1016/j.sab.2024.107019\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Plasma grating-induced breakdown spectroscopy (GIBS) has gained notable attention for its capacity in trace metal element detection. This study examined the utilization of plasma grating to create micropores and nanoparticles on a Si sample surface and explored their impact on GIBS. We found that the presence of these features resulted in a significant 2.4-fold enhancement in the spectral intensity of the Si plasma at a laser energy of 2.7 mJ, with micropores structures and nanoparticles promoting the plasma excitation. Furthermore, the effect of micropores structures and nanoparticles on the spectral intensities of Cr and Cd elements in water was investigated. Significantly, the spectral line intensity of heavy metal Cr and Cd in the etched area was about 4.5 and 2.6 times that of the unetched area, and the detection limit for trace levels of Cr and Cd in water was determined to be 6.40 mg/L and 75.0 mg/L, respectively. These findings highlight the promising potential of the enhanced GIBS as a more sensitive method for detecting trace metal elements in water.</p></div>\",\"PeriodicalId\":21890,\"journal\":{\"name\":\"Spectrochimica Acta Part B: Atomic Spectroscopy\",\"volume\":\"220 \",\"pages\":\"Article 107019\"},\"PeriodicalIF\":3.2000,\"publicationDate\":\"2024-08-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Spectrochimica Acta Part B: Atomic Spectroscopy\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0584854724001630\",\"RegionNum\":2,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"SPECTROSCOPY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Spectrochimica Acta Part B: Atomic Spectroscopy","FirstCategoryId":"92","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0584854724001630","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"SPECTROSCOPY","Score":null,"Total":0}
引用次数: 0

摘要

等离子体光栅诱导击穿光谱(GIBS)因其在痕量金属元素检测方面的能力而备受关注。本研究利用等离子体光栅在硅样品表面形成微孔和纳米颗粒,并探讨它们对 GIBS 的影响。我们发现,在激光能量为 2.7 mJ 时,这些特征的存在使硅等离子体的光谱强度显著增强了 2.4 倍,其中微孔结构和纳米颗粒促进了等离子体的激发。此外,还研究了微孔结构和纳米颗粒对水中铬和镉元素光谱强度的影响。值得注意的是,蚀刻区重金属铬和镉的光谱线强度分别是未蚀刻区的 4.5 倍和 2.6 倍,水中痕量铬和镉的检测限分别为 6.40 毫克/升和 75.0 毫克/升。这些发现凸显了增强型 GIBS 作为一种更灵敏的检测水中痕量金属元素方法的巨大潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Enhanced plasma grating-induced breakdown spectroscopy for sensitive detection of heavy metal in solution

Plasma grating-induced breakdown spectroscopy (GIBS) has gained notable attention for its capacity in trace metal element detection. This study examined the utilization of plasma grating to create micropores and nanoparticles on a Si sample surface and explored their impact on GIBS. We found that the presence of these features resulted in a significant 2.4-fold enhancement in the spectral intensity of the Si plasma at a laser energy of 2.7 mJ, with micropores structures and nanoparticles promoting the plasma excitation. Furthermore, the effect of micropores structures and nanoparticles on the spectral intensities of Cr and Cd elements in water was investigated. Significantly, the spectral line intensity of heavy metal Cr and Cd in the etched area was about 4.5 and 2.6 times that of the unetched area, and the detection limit for trace levels of Cr and Cd in water was determined to be 6.40 mg/L and 75.0 mg/L, respectively. These findings highlight the promising potential of the enhanced GIBS as a more sensitive method for detecting trace metal elements in water.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
6.10
自引率
12.10%
发文量
173
审稿时长
81 days
期刊介绍: Spectrochimica Acta Part B: Atomic Spectroscopy, is intended for the rapid publication of both original work and reviews in the following fields: Atomic Emission (AES), Atomic Absorption (AAS) and Atomic Fluorescence (AFS) spectroscopy; Mass Spectrometry (MS) for inorganic analysis covering Spark Source (SS-MS), Inductively Coupled Plasma (ICP-MS), Glow Discharge (GD-MS), and Secondary Ion Mass Spectrometry (SIMS). Laser induced atomic spectroscopy for inorganic analysis, including non-linear optical laser spectroscopy, covering Laser Enhanced Ionization (LEI), Laser Induced Fluorescence (LIF), Resonance Ionization Spectroscopy (RIS) and Resonance Ionization Mass Spectrometry (RIMS); Laser Induced Breakdown Spectroscopy (LIBS); Cavity Ringdown Spectroscopy (CRDS), Laser Ablation Inductively Coupled Plasma Atomic Emission Spectroscopy (LA-ICP-AES) and Laser Ablation Inductively Coupled Plasma Mass Spectrometry (LA-ICP-MS). X-ray spectrometry, X-ray Optics and Microanalysis, including X-ray fluorescence spectrometry (XRF) and related techniques, in particular Total-reflection X-ray Fluorescence Spectrometry (TXRF), and Synchrotron Radiation-excited Total reflection XRF (SR-TXRF). Manuscripts dealing with (i) fundamentals, (ii) methodology development, (iii)instrumentation, and (iv) applications, can be submitted for publication.
期刊最新文献
Assessment of acupuncture's effectiveness in treating gulf war illness using laser induced breakdown spectroscopy and inductively coupled plasma mass spectrometry Characterization of the distribution of mineral elements in chromium-stressed rice (Oryza sativa L.) leaves based on laser-induced breakdown spectroscopy and data augmentation Rapid determination of 90Sr in seawater using a novel porous crown-based resin and tandem quadrupole ICP-MS/MS in cool plasma and O2-He mode Consideration of spectral interference in total reflection X-ray fluorescence analysis using a limited number of calibration samples: Case study of ocean polymetallic nodules Signal enhancement with double-pulse LIBS on biological samples and better discrimination of tissues through machine learning algorithms
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1