治疗真性胸腔动脉瘤的 Frozenix 最佳尺寸:是否可以缩小尺寸?

IF 1.1 4区 医学 Q4 CARDIAC & CARDIOVASCULAR SYSTEMS General Thoracic and Cardiovascular Surgery Pub Date : 2024-09-04 DOI:10.1007/s11748-024-02074-2
Jun Hayashi, Shingo Nakai, Kimihiro Kobayashi, Yoshinori Kuroda, Eiichi Ohba, Masahiro Mizumoto, Atsushi Yamashita, Tomonori Ochiai, Tetsuro Uchida
{"title":"治疗真性胸腔动脉瘤的 Frozenix 最佳尺寸:是否可以缩小尺寸?","authors":"Jun Hayashi, Shingo Nakai, Kimihiro Kobayashi, Yoshinori Kuroda, Eiichi Ohba, Masahiro Mizumoto, Atsushi Yamashita, Tomonori Ochiai, Tetsuro Uchida","doi":"10.1007/s11748-024-02074-2","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>During total arch replacement (TAR) using frozen elephant trunk (FET) technique with Frozenix for true thoracic aortic aneurysm (tTAA), oversized FET tends to be chosen similar to the endovascular devise selection. However, the oversized FET is considered a risk factor for intimal injury. The appropriate size selection of FET remains insufficiently understood.</p><p><strong>Methods: </strong>Between October 2014 and March 2022, a total of 49 patients underwent TAR using Frozenix for tTAA. Out of 49 patients, four patients planned to staged surgery were excluded, 19 patients were operated on with an undersized Frozenix compared with the descending aorta (undersized FET group) and in 26 patients an equal or oversized Frozenix was used (oversized FET group). Clinical outcomes and postoperative diameter changes were investigated.</p><p><strong>Results: </strong>In-hospital mortality was 0%. The mean diameter of Frozenix and the descending aorta was 30.7 mm and 28.8 mm, respectively, in the oversized FET group, and 26.7 mm and 30.1 mm in the undersized FET group. Postoperative computed tomography (CT) demonstrated no endoleaks not only in the oversized FET group but also in the undersized FET group. CT also revealed that undersized FET had expanded more than the original diameter in all cases except for two, with an average of 2.47 ± 1.53 mm. Additionally, the descending aorta covered with Frozenix shrank in 10 patients (53%). Postoperative adverse aortic events were not observed.</p><p><strong>Conclusions: </strong>Undersized Frozenix tightly fit the descending aorta and resulted in complete sealing without endoleaks. Oversized FET is not strictly necessary considering the size-related adverse complications.</p>","PeriodicalId":12585,"journal":{"name":"General Thoracic and Cardiovascular Surgery","volume":" ","pages":""},"PeriodicalIF":1.1000,"publicationDate":"2024-09-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Optimal size of Frozenix for true thoracic aneurysms: is downsizing an option?\",\"authors\":\"Jun Hayashi, Shingo Nakai, Kimihiro Kobayashi, Yoshinori Kuroda, Eiichi Ohba, Masahiro Mizumoto, Atsushi Yamashita, Tomonori Ochiai, Tetsuro Uchida\",\"doi\":\"10.1007/s11748-024-02074-2\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>During total arch replacement (TAR) using frozen elephant trunk (FET) technique with Frozenix for true thoracic aortic aneurysm (tTAA), oversized FET tends to be chosen similar to the endovascular devise selection. However, the oversized FET is considered a risk factor for intimal injury. The appropriate size selection of FET remains insufficiently understood.</p><p><strong>Methods: </strong>Between October 2014 and March 2022, a total of 49 patients underwent TAR using Frozenix for tTAA. Out of 49 patients, four patients planned to staged surgery were excluded, 19 patients were operated on with an undersized Frozenix compared with the descending aorta (undersized FET group) and in 26 patients an equal or oversized Frozenix was used (oversized FET group). Clinical outcomes and postoperative diameter changes were investigated.</p><p><strong>Results: </strong>In-hospital mortality was 0%. The mean diameter of Frozenix and the descending aorta was 30.7 mm and 28.8 mm, respectively, in the oversized FET group, and 26.7 mm and 30.1 mm in the undersized FET group. Postoperative computed tomography (CT) demonstrated no endoleaks not only in the oversized FET group but also in the undersized FET group. CT also revealed that undersized FET had expanded more than the original diameter in all cases except for two, with an average of 2.47 ± 1.53 mm. Additionally, the descending aorta covered with Frozenix shrank in 10 patients (53%). Postoperative adverse aortic events were not observed.</p><p><strong>Conclusions: </strong>Undersized Frozenix tightly fit the descending aorta and resulted in complete sealing without endoleaks. Oversized FET is not strictly necessary considering the size-related adverse complications.</p>\",\"PeriodicalId\":12585,\"journal\":{\"name\":\"General Thoracic and Cardiovascular Surgery\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2024-09-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"General Thoracic and Cardiovascular Surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s11748-024-02074-2\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"General Thoracic and Cardiovascular Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s11748-024-02074-2","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

目的:在使用冷冻大象躯干(FET)技术和 Frozenix 治疗真性胸主动脉瘤(tTAA)的全弓置换术(TAR)中,往往会选择过大的 FET,这与血管内设备的选择类似。然而,过大的 FET 被认为是内膜损伤的风险因素。如何选择合适尺寸的 FET 仍未得到充分了解:2014年10月至2022年3月期间,共有49名患者使用Frozenix为tTAA进行了TAR手术。在 49 例患者中,有 4 例计划分期手术的患者被排除在外,19 例患者使用了与降主动脉相比过小的 Frozenix 进行手术(过小 FET 组),26 例患者使用了相同或过大的 Frozenix(过大 FET 组)。对临床结果和术后直径变化进行了调查:结果:院内死亡率为 0%。过大 FET 组的 Frozenix 和降主动脉平均直径分别为 30.7 毫米和 28.8 毫米,过小 FET 组的 Frozenix 和降主动脉平均直径分别为 26.7 毫米和 30.1 毫米。术后计算机断层扫描(CT)显示,不仅过大 FET 组没有内漏,过小 FET 组也没有内漏。计算机断层扫描还显示,除两个病例外,所有病例的过小 FET 的扩张都超过了原始直径,平均为 2.47 ± 1.53 毫米。此外,10 名患者(53%)的降主动脉在 Frozenix 的覆盖下缩小。术后未观察到主动脉不良事件:尺寸过小的 Frozenix 与降主动脉紧密贴合,实现了完全密封,没有内漏。考虑到与尺寸相关的不良并发症,过大的 FET 严格来说并非必要。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Optimal size of Frozenix for true thoracic aneurysms: is downsizing an option?

Objective: During total arch replacement (TAR) using frozen elephant trunk (FET) technique with Frozenix for true thoracic aortic aneurysm (tTAA), oversized FET tends to be chosen similar to the endovascular devise selection. However, the oversized FET is considered a risk factor for intimal injury. The appropriate size selection of FET remains insufficiently understood.

Methods: Between October 2014 and March 2022, a total of 49 patients underwent TAR using Frozenix for tTAA. Out of 49 patients, four patients planned to staged surgery were excluded, 19 patients were operated on with an undersized Frozenix compared with the descending aorta (undersized FET group) and in 26 patients an equal or oversized Frozenix was used (oversized FET group). Clinical outcomes and postoperative diameter changes were investigated.

Results: In-hospital mortality was 0%. The mean diameter of Frozenix and the descending aorta was 30.7 mm and 28.8 mm, respectively, in the oversized FET group, and 26.7 mm and 30.1 mm in the undersized FET group. Postoperative computed tomography (CT) demonstrated no endoleaks not only in the oversized FET group but also in the undersized FET group. CT also revealed that undersized FET had expanded more than the original diameter in all cases except for two, with an average of 2.47 ± 1.53 mm. Additionally, the descending aorta covered with Frozenix shrank in 10 patients (53%). Postoperative adverse aortic events were not observed.

Conclusions: Undersized Frozenix tightly fit the descending aorta and resulted in complete sealing without endoleaks. Oversized FET is not strictly necessary considering the size-related adverse complications.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
General Thoracic and Cardiovascular Surgery
General Thoracic and Cardiovascular Surgery Medicine-Pulmonary and Respiratory Medicine
CiteScore
2.70
自引率
8.30%
发文量
142
期刊介绍: The General Thoracic and Cardiovascular Surgery is the official publication of The Japanese Association for Thoracic Surgery and The Japanese Association for Chest Surgery, the affiliated journal of The Japanese Society for Cardiovascular Surgery, that publishes clinical and experimental studies in fields related to thoracic and cardiovascular surgery.
期刊最新文献
Postoperative pulmonary function of patients with lung cancer and interstitial lung abnormalities. Lessons from short chest drain management for primary spontaneous pneumothorax. Long-term results of the frozen elephant trunk technique in primary chronic type B aortic dissection. A balanced mitral leaflet and large ring strategy avoids systolic anterior motion in Barlow's disease. Preoperative neutrophil-to-lymphocyte ratio predicts recurrence of esophageal squamous cell carcinoma after neoadjuvant triplet chemotherapy.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1