通过试点计划防止 Mho 距离继电器在负载侵占情况下误动作

IF 1.6 4区 工程技术 Q3 ENGINEERING, ELECTRICAL & ELECTRONIC Journal of Electrical Engineering & Technology Pub Date : 2024-09-04 DOI:10.1007/s42835-024-02019-y
Sujitha Arasu, Rathinam Ananthanarayanan
{"title":"通过试点计划防止 Mho 距离继电器在负载侵占情况下误动作","authors":"Sujitha Arasu, Rathinam Ananthanarayanan","doi":"10.1007/s42835-024-02019-y","DOIUrl":null,"url":null,"abstract":"<p>Distance relays are crucial components of power transmission systems, providing protection against faults and ensuring the stability and reliability of the electrical grid. However, under certain conditions, they may experience maloperations, leading to erroneous tripping or failure to trip during fault events. The proposed scheme incorporates a modified Mho characteristics for monitoring load impedance to improve loadability during load encroachment conditions and prevent false tripping. In addition, the pilot scheme Permissive Under reach Transfer Trip (PUTT) provides communication capabilities enhancing the relay’s accuracy in fault detection. Extensive simulations and tests are conducted using MATLAB/Simulink to validate the effectiveness of the pilot scheme in EMTP (Electro Magnetic Transient Program) environment. The results indicate that the proposed scheme achieves faster detection of remote circuit breaker operations by 520ms bypassing the Zone 2 set delay of 500ms also. The scheme offers a practical and cost-effective solution to mitigate the challenges associated with load encroachment and enhance the overall stability and reliability of power systems.</p>","PeriodicalId":15577,"journal":{"name":"Journal of Electrical Engineering & Technology","volume":null,"pages":null},"PeriodicalIF":1.6000,"publicationDate":"2024-09-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Preventing Maloperation of Mho Distance Relays During Load Encroachment Conditions Through a Pilot Scheme\",\"authors\":\"Sujitha Arasu, Rathinam Ananthanarayanan\",\"doi\":\"10.1007/s42835-024-02019-y\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Distance relays are crucial components of power transmission systems, providing protection against faults and ensuring the stability and reliability of the electrical grid. However, under certain conditions, they may experience maloperations, leading to erroneous tripping or failure to trip during fault events. The proposed scheme incorporates a modified Mho characteristics for monitoring load impedance to improve loadability during load encroachment conditions and prevent false tripping. In addition, the pilot scheme Permissive Under reach Transfer Trip (PUTT) provides communication capabilities enhancing the relay’s accuracy in fault detection. Extensive simulations and tests are conducted using MATLAB/Simulink to validate the effectiveness of the pilot scheme in EMTP (Electro Magnetic Transient Program) environment. The results indicate that the proposed scheme achieves faster detection of remote circuit breaker operations by 520ms bypassing the Zone 2 set delay of 500ms also. The scheme offers a practical and cost-effective solution to mitigate the challenges associated with load encroachment and enhance the overall stability and reliability of power systems.</p>\",\"PeriodicalId\":15577,\"journal\":{\"name\":\"Journal of Electrical Engineering & Technology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2024-09-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Electrical Engineering & Technology\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1007/s42835-024-02019-y\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Electrical Engineering & Technology","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s42835-024-02019-y","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

摘要

距离继电器是输电系统的重要组成部分,可提供故障保护并确保电网的稳定性和可靠性。然而,在某些条件下,它们可能会出现误动作,导致在故障事件中错误跳闸或无法跳闸。拟议方案采用改进的 Mho 特性来监测负载阻抗,以提高负载侵蚀条件下的可负载性,防止误跳闸。此外,试验方案允许欠压转移跳闸(PUTT)提供了通信功能,提高了继电器故障检测的准确性。我们使用 MATLAB/Simulink 进行了大量模拟和测试,以验证试点方案在 EMTP(电磁暂态程序)环境中的有效性。结果表明,拟议方案绕过了 2 区 500ms 的设定延迟,以 520ms 的速度实现了对远程断路器操作的快速检测。该方案提供了一个实用且经济高效的解决方案,可减轻与负载侵蚀相关的挑战,提高电力系统的整体稳定性和可靠性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Preventing Maloperation of Mho Distance Relays During Load Encroachment Conditions Through a Pilot Scheme

Distance relays are crucial components of power transmission systems, providing protection against faults and ensuring the stability and reliability of the electrical grid. However, under certain conditions, they may experience maloperations, leading to erroneous tripping or failure to trip during fault events. The proposed scheme incorporates a modified Mho characteristics for monitoring load impedance to improve loadability during load encroachment conditions and prevent false tripping. In addition, the pilot scheme Permissive Under reach Transfer Trip (PUTT) provides communication capabilities enhancing the relay’s accuracy in fault detection. Extensive simulations and tests are conducted using MATLAB/Simulink to validate the effectiveness of the pilot scheme in EMTP (Electro Magnetic Transient Program) environment. The results indicate that the proposed scheme achieves faster detection of remote circuit breaker operations by 520ms bypassing the Zone 2 set delay of 500ms also. The scheme offers a practical and cost-effective solution to mitigate the challenges associated with load encroachment and enhance the overall stability and reliability of power systems.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Electrical Engineering & Technology
Journal of Electrical Engineering & Technology ENGINEERING, ELECTRICAL & ELECTRONIC-
CiteScore
4.00
自引率
15.80%
发文量
321
审稿时长
3.8 months
期刊介绍: ournal of Electrical Engineering and Technology (JEET), which is the official publication of the Korean Institute of Electrical Engineers (KIEE) being published bimonthly, released the first issue in March 2006.The journal is open to submission from scholars and experts in the wide areas of electrical engineering technologies. The scope of the journal includes all issues in the field of Electrical Engineering and Technology. Included are techniques for electrical power engineering, electrical machinery and energy conversion systems, electrophysics and applications, information and controls.
期刊最新文献
Parameter Solution of Fractional Order PID Controller for Home Ventilator Based on Genetic-Ant Colony Algorithm Fault Detection of Flexible DC Grid Based on Empirical Wavelet Transform and WOA-CNN Aggregation and Bidding Strategy of Virtual Power Plant Power Management of Hybrid System Using Coronavirus Herd Immunity Optimizer Algorithm A Review on Power System Security Issues in the High Renewable Energy Penetration Environment
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1