Jayun Kim, Yoon-ji Kim, Sook-young Lee, Jae-Ku Oem, Subin Kim, Keugtae Kim, Woosik Jung, Sungpyo Kim, Dong-Hwan Jeong, Minjoo Lee, Soo-Hyung Lee, Hyunook Kim and Joonhong Park
{"title":"韩国城市污水设施中 SARS-CoV-2 的检测和感染性以及影响污水中 SARS-CoV-2 的环境因素的特征描述","authors":"Jayun Kim, Yoon-ji Kim, Sook-young Lee, Jae-Ku Oem, Subin Kim, Keugtae Kim, Woosik Jung, Sungpyo Kim, Dong-Hwan Jeong, Minjoo Lee, Soo-Hyung Lee, Hyunook Kim and Joonhong Park","doi":"10.1039/D4EW00334A","DOIUrl":null,"url":null,"abstract":"<p >Wastewater-based epidemiology can track infectious diseases and COVID-19 surges. There is variability in viral signals from wastewater owing to numerous sample processing and virus detection methods, and many factors including characteristics of wastewater treatment plants (WWTPs) should be considered to consistently associate the signals with COVID-19 prevalence. This study optimized the virus detection method, validated the use of a process-control virus, investigated 22 WWTPs across South Korea (covering approximately 20% of the population) during two periods (24.8 <em>versus</em> 2027.4 weekly COVID-19 cases per 100 000 people), tested the infectivity of SARS-CoV-2 in wastewater, and characterized the environmental factors influencing wastewater-bound SARS-CoV-2 and local COVID-19 using data-driven models (DDMs). The most sensitive virus quantification methods were selected (PEG precipitation and commercial kits for RT-qPCR detection, approximately 39% more sensitive) by comparing various methods. Using a surrogate virus showed reduced variation (approximately 24%) between the intra- and inter-laboratory results. The number of WWTPs with positive detection of SARS-CoV-2 in raw wastewater increased (four to twenty) as the national COVID-19 cases peaked. SARS-CoV-2 is more likely to be detected in moderately sized facilities located in populated areas with sanitary sewer systems. In addition, results of infectivity testing suggested no potential for COVID-19 transmission through wastewater. The DDMs indicated that the air temperature, water quality, and number of COVID-19 cases were related to the SARS-CoV-2 in wastewater. Community COVID-19 cases were predicted (test performance: 0.703–0.970) with the data on wastewater viral load and other variables implying that these factors should be monitored for wastewater surveillance.</p>","PeriodicalId":75,"journal":{"name":"Environmental Science: Water Research & Technology","volume":" 11","pages":" 2752-2764"},"PeriodicalIF":3.5000,"publicationDate":"2024-08-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Detection and infectivity of SARS-CoV-2 in Korean municipal wastewater facilities and characterization of environmental factors influencing wastewater-bound SARS-CoV-2†\",\"authors\":\"Jayun Kim, Yoon-ji Kim, Sook-young Lee, Jae-Ku Oem, Subin Kim, Keugtae Kim, Woosik Jung, Sungpyo Kim, Dong-Hwan Jeong, Minjoo Lee, Soo-Hyung Lee, Hyunook Kim and Joonhong Park\",\"doi\":\"10.1039/D4EW00334A\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p >Wastewater-based epidemiology can track infectious diseases and COVID-19 surges. There is variability in viral signals from wastewater owing to numerous sample processing and virus detection methods, and many factors including characteristics of wastewater treatment plants (WWTPs) should be considered to consistently associate the signals with COVID-19 prevalence. This study optimized the virus detection method, validated the use of a process-control virus, investigated 22 WWTPs across South Korea (covering approximately 20% of the population) during two periods (24.8 <em>versus</em> 2027.4 weekly COVID-19 cases per 100 000 people), tested the infectivity of SARS-CoV-2 in wastewater, and characterized the environmental factors influencing wastewater-bound SARS-CoV-2 and local COVID-19 using data-driven models (DDMs). The most sensitive virus quantification methods were selected (PEG precipitation and commercial kits for RT-qPCR detection, approximately 39% more sensitive) by comparing various methods. Using a surrogate virus showed reduced variation (approximately 24%) between the intra- and inter-laboratory results. The number of WWTPs with positive detection of SARS-CoV-2 in raw wastewater increased (four to twenty) as the national COVID-19 cases peaked. SARS-CoV-2 is more likely to be detected in moderately sized facilities located in populated areas with sanitary sewer systems. In addition, results of infectivity testing suggested no potential for COVID-19 transmission through wastewater. The DDMs indicated that the air temperature, water quality, and number of COVID-19 cases were related to the SARS-CoV-2 in wastewater. Community COVID-19 cases were predicted (test performance: 0.703–0.970) with the data on wastewater viral load and other variables implying that these factors should be monitored for wastewater surveillance.</p>\",\"PeriodicalId\":75,\"journal\":{\"name\":\"Environmental Science: Water Research & Technology\",\"volume\":\" 11\",\"pages\":\" 2752-2764\"},\"PeriodicalIF\":3.5000,\"publicationDate\":\"2024-08-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Environmental Science: Water Research & Technology\",\"FirstCategoryId\":\"93\",\"ListUrlMain\":\"https://pubs.rsc.org/en/content/articlelanding/2024/ew/d4ew00334a\",\"RegionNum\":4,\"RegionCategory\":\"环境科学与生态学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, ENVIRONMENTAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Environmental Science: Water Research & Technology","FirstCategoryId":"93","ListUrlMain":"https://pubs.rsc.org/en/content/articlelanding/2024/ew/d4ew00334a","RegionNum":4,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, ENVIRONMENTAL","Score":null,"Total":0}
Detection and infectivity of SARS-CoV-2 in Korean municipal wastewater facilities and characterization of environmental factors influencing wastewater-bound SARS-CoV-2†
Wastewater-based epidemiology can track infectious diseases and COVID-19 surges. There is variability in viral signals from wastewater owing to numerous sample processing and virus detection methods, and many factors including characteristics of wastewater treatment plants (WWTPs) should be considered to consistently associate the signals with COVID-19 prevalence. This study optimized the virus detection method, validated the use of a process-control virus, investigated 22 WWTPs across South Korea (covering approximately 20% of the population) during two periods (24.8 versus 2027.4 weekly COVID-19 cases per 100 000 people), tested the infectivity of SARS-CoV-2 in wastewater, and characterized the environmental factors influencing wastewater-bound SARS-CoV-2 and local COVID-19 using data-driven models (DDMs). The most sensitive virus quantification methods were selected (PEG precipitation and commercial kits for RT-qPCR detection, approximately 39% more sensitive) by comparing various methods. Using a surrogate virus showed reduced variation (approximately 24%) between the intra- and inter-laboratory results. The number of WWTPs with positive detection of SARS-CoV-2 in raw wastewater increased (four to twenty) as the national COVID-19 cases peaked. SARS-CoV-2 is more likely to be detected in moderately sized facilities located in populated areas with sanitary sewer systems. In addition, results of infectivity testing suggested no potential for COVID-19 transmission through wastewater. The DDMs indicated that the air temperature, water quality, and number of COVID-19 cases were related to the SARS-CoV-2 in wastewater. Community COVID-19 cases were predicted (test performance: 0.703–0.970) with the data on wastewater viral load and other variables implying that these factors should be monitored for wastewater surveillance.
期刊介绍:
Environmental Science: Water Research & Technology seeks to showcase high quality research about fundamental science, innovative technologies, and management practices that promote sustainable water.