Thi Lieu Tran, Thi Anh Huong Nguyen, Thi Lan Phuong Kieu, Thi Huyen Trang Luu, Thi Thu Hang Do, Hieu Duc Nguyen, Trung Quang Pham, Huy Quang Nguyen, Hasara Savindi Rupasinghe, Le Huu Tuyen, Thi Quynh Hoa Nguyen, Anh Quoc Hoang
{"title":"食品接触材料中的可萃取全氟烷基羧酸和磺酸盐:通过超声波萃取、分散性吸附剂净化和 LC-MS/MS 定量开发简易分析方法","authors":"Thi Lieu Tran,&nbsp;Thi Anh Huong Nguyen,&nbsp;Thi Lan Phuong Kieu,&nbsp;Thi Huyen Trang Luu,&nbsp;Thi Thu Hang Do,&nbsp;Hieu Duc Nguyen,&nbsp;Trung Quang Pham,&nbsp;Huy Quang Nguyen,&nbsp;Hasara Savindi Rupasinghe,&nbsp;Le Huu Tuyen,&nbsp;Thi Quynh Hoa Nguyen,&nbsp;Anh Quoc Hoang","doi":"10.1134/S1061934824700667","DOIUrl":null,"url":null,"abstract":"<p>Poly- and perfluoroalkyl substances (<b>PFAS</b>s) have attracted great scientific attention because of their environmental persistence, bioaccumulation potentials, and toxicity. This study validated a simple and efficient sample preparation method for determining extractable PFASs, including 12 perfluoroalkyl carboxylic acids and 4 perfluoroalkyl sulfonates. The samples underwent ultrasonic extraction, and the extracts were cleaned up by dispersive solid-phase extraction technique with graphitized carbon if necessary. PFAS quantification was performed by a liquid chromatography-tandem mass spectrometry system. The instrument provided analytical signals for all target compounds with good repeatability (RSD &lt; 15%), reproducibility (RSD &lt; 20%), linearity (<i>R</i><sup>2</sup> &gt; 0.99), and low detection limits (0.10–1.0 ng/mL). The validated method exhibited adequate recovery (70–115%), precision (RSD &lt; 15%), and method detection limits (0.020–0.70 ng/g). This validated method was applied to analyze PFASs in several food packaging samples collected in Vietnam, showing very low levels (range 0.090–2.9 ng/g; median 0.72 ng/g) derived from unintentional sources.</p>","PeriodicalId":606,"journal":{"name":"Journal of Analytical Chemistry","volume":null,"pages":null},"PeriodicalIF":1.0000,"publicationDate":"2024-09-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Extractable Perfluoroalkyl Carboxylic Acids and Sulfonates in Food Contact Materials: Development of a Simple Analytical Method with Ultrasonic Extraction, Dispersive Sorbent Clean-Up, and LC-MS/MS Quantification\",\"authors\":\"Thi Lieu Tran,&nbsp;Thi Anh Huong Nguyen,&nbsp;Thi Lan Phuong Kieu,&nbsp;Thi Huyen Trang Luu,&nbsp;Thi Thu Hang Do,&nbsp;Hieu Duc Nguyen,&nbsp;Trung Quang Pham,&nbsp;Huy Quang Nguyen,&nbsp;Hasara Savindi Rupasinghe,&nbsp;Le Huu Tuyen,&nbsp;Thi Quynh Hoa Nguyen,&nbsp;Anh Quoc Hoang\",\"doi\":\"10.1134/S1061934824700667\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Poly- and perfluoroalkyl substances (<b>PFAS</b>s) have attracted great scientific attention because of their environmental persistence, bioaccumulation potentials, and toxicity. This study validated a simple and efficient sample preparation method for determining extractable PFASs, including 12 perfluoroalkyl carboxylic acids and 4 perfluoroalkyl sulfonates. The samples underwent ultrasonic extraction, and the extracts were cleaned up by dispersive solid-phase extraction technique with graphitized carbon if necessary. PFAS quantification was performed by a liquid chromatography-tandem mass spectrometry system. The instrument provided analytical signals for all target compounds with good repeatability (RSD &lt; 15%), reproducibility (RSD &lt; 20%), linearity (<i>R</i><sup>2</sup> &gt; 0.99), and low detection limits (0.10–1.0 ng/mL). The validated method exhibited adequate recovery (70–115%), precision (RSD &lt; 15%), and method detection limits (0.020–0.70 ng/g). This validated method was applied to analyze PFASs in several food packaging samples collected in Vietnam, showing very low levels (range 0.090–2.9 ng/g; median 0.72 ng/g) derived from unintentional sources.</p>\",\"PeriodicalId\":606,\"journal\":{\"name\":\"Journal of Analytical Chemistry\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2024-09-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Analytical Chemistry\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://link.springer.com/article/10.1134/S1061934824700667\",\"RegionNum\":4,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Analytical Chemistry","FirstCategoryId":"92","ListUrlMain":"https://link.springer.com/article/10.1134/S1061934824700667","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

摘要 全氟烷基和全氟烷基化合物(PFASs)因其环境持久性、生物累积潜力和毒性而受到科学界的高度关注。本研究验证了一种简单高效的样品制备方法,用于测定可萃取的 PFASs,包括 12 种全氟烷基羧酸和 4 种全氟烷基磺酸盐。样品经过超声波萃取,必要时使用分散固相萃取技术和石墨化碳对萃取物进行净化。采用液相色谱-串联质谱系统对 PFAS 进行定量。该仪器可提供所有目标化合物的分析信号,具有良好的重复性(RSD < 15%)、再现性(RSD < 20%)、线性(R2 > 0.99)和低检测限(0.10-1.0 ng/mL)。该方法的回收率(70-115%)、精密度(RSD <15%)和方法检出限(0.020-0.70 ng/g)均符合要求。该验证方法被用于分析在越南采集的几个食品包装样品中的全氟辛烷磺酸,结果显示,这些样品中的全氟辛烷磺酸含量非常低(范围为 0.090-2.9 纳克/克;中位数为 0.72 纳克/克),这些样品来自非有意来源。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Extractable Perfluoroalkyl Carboxylic Acids and Sulfonates in Food Contact Materials: Development of a Simple Analytical Method with Ultrasonic Extraction, Dispersive Sorbent Clean-Up, and LC-MS/MS Quantification

Poly- and perfluoroalkyl substances (PFASs) have attracted great scientific attention because of their environmental persistence, bioaccumulation potentials, and toxicity. This study validated a simple and efficient sample preparation method for determining extractable PFASs, including 12 perfluoroalkyl carboxylic acids and 4 perfluoroalkyl sulfonates. The samples underwent ultrasonic extraction, and the extracts were cleaned up by dispersive solid-phase extraction technique with graphitized carbon if necessary. PFAS quantification was performed by a liquid chromatography-tandem mass spectrometry system. The instrument provided analytical signals for all target compounds with good repeatability (RSD < 15%), reproducibility (RSD < 20%), linearity (R2 > 0.99), and low detection limits (0.10–1.0 ng/mL). The validated method exhibited adequate recovery (70–115%), precision (RSD < 15%), and method detection limits (0.020–0.70 ng/g). This validated method was applied to analyze PFASs in several food packaging samples collected in Vietnam, showing very low levels (range 0.090–2.9 ng/g; median 0.72 ng/g) derived from unintentional sources.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Analytical Chemistry
Journal of Analytical Chemistry 化学-分析化学
CiteScore
2.10
自引率
9.10%
发文量
146
审稿时长
13 months
期刊介绍: The Journal of Analytical Chemistry is an international peer reviewed journal that covers theoretical and applied aspects of analytical chemistry; it informs the reader about new achievements in analytical methods, instruments and reagents. Ample space is devoted to problems arising in the analysis of vital media such as water and air. Consideration is given to the detection and determination of metal ions, anions, and various organic substances. The journal welcomes manuscripts from all countries in the English or Russian language.
期刊最新文献
Separation of Chlorogenic Acids and Caffeine on a Diasfer-110-C10CN Stationary Phase Development, Validation, and Quantification of Organic Impurities with Mass Balance in the Levodopa and Benserazide Hydrochloride Pharmaceutical Dosage Form Surface-Assisted Laser Desorption/Ionization of Metal Complexes with Dithizone Determination of Potassium, Neodymium, and Strontium in Solid Solutions in the KNd(SO4)2·H2O–SrSO4·0.5H2O System Using X-Ray Fluorescence Spectrometry Thin-Layer Chromatography of Methylated Derivatives of Linear Alkylbenzene Sulfonates in Water Analysis by Gas Chromatography–Mass Spectrometry
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1