基于摩擦阻尼器和钢管的垂直循环立体车库抗震性能研究

Yang‐yang Guo, Zu‐zhi Tian, Xiang‐fan Wu, Li‐yuan Tan, Hao‐peng Li
{"title":"基于摩擦阻尼器和钢管的垂直循环立体车库抗震性能研究","authors":"Yang‐yang Guo, Zu‐zhi Tian, Xiang‐fan Wu, Li‐yuan Tan, Hao‐peng Li","doi":"10.1002/tal.2177","DOIUrl":null,"url":null,"abstract":"The conventional vertical circulation stereo garage is susceptible to deformation and instability when subjected to extreme seismic loads and complex working conditions. The present study introduces the combination arrangement of steel pipe and friction damper to optimize vertical circulation stereo garage while also investigating their seismic suppression performance under three representative seismic waves (EL‐CNENTRO, TH1TG025(TH), and RH1TG025(RH)). The results showed that the garage structure hasbetter seismic suppression performance when the combination of steel pipes and friction dampers is applied in Scheme 4 compared to relying solely on diagonal tie rod, steel pipe or friction damper. And Scheme 4 achieves inhibition rates of up to 61.27%, 22.12%, 56.07%, and 12.84% for overall maximum deformation response, maximum Y‐direction deformation response, vertex acceleration response, and bottom shear response, respectively. This enhancement significantly improves the garage's seismic stability, providing valuable theoretical references for advancing the development and market promotion of vertical circulation stereo garages.","PeriodicalId":501238,"journal":{"name":"The Structural Design of Tall and Special Buildings","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-09-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Research on seismic suppression performance of vertical circulation stereo garage based on friction damper and steel pipe\",\"authors\":\"Yang‐yang Guo, Zu‐zhi Tian, Xiang‐fan Wu, Li‐yuan Tan, Hao‐peng Li\",\"doi\":\"10.1002/tal.2177\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The conventional vertical circulation stereo garage is susceptible to deformation and instability when subjected to extreme seismic loads and complex working conditions. The present study introduces the combination arrangement of steel pipe and friction damper to optimize vertical circulation stereo garage while also investigating their seismic suppression performance under three representative seismic waves (EL‐CNENTRO, TH1TG025(TH), and RH1TG025(RH)). The results showed that the garage structure hasbetter seismic suppression performance when the combination of steel pipes and friction dampers is applied in Scheme 4 compared to relying solely on diagonal tie rod, steel pipe or friction damper. And Scheme 4 achieves inhibition rates of up to 61.27%, 22.12%, 56.07%, and 12.84% for overall maximum deformation response, maximum Y‐direction deformation response, vertex acceleration response, and bottom shear response, respectively. This enhancement significantly improves the garage's seismic stability, providing valuable theoretical references for advancing the development and market promotion of vertical circulation stereo garages.\",\"PeriodicalId\":501238,\"journal\":{\"name\":\"The Structural Design of Tall and Special Buildings\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-09-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The Structural Design of Tall and Special Buildings\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1002/tal.2177\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Structural Design of Tall and Special Buildings","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/tal.2177","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

传统的垂直循环立体车库在极端地震荷载和复杂工况下容易发生变形和失稳。本研究介绍了钢管和摩擦阻尼器的组合布置,以优化垂直循环立体车库,同时还研究了其在三种代表性地震波(EL-CNENTRO、TH1TG025(TH)和 RH1TG025(RH))下的抗震性能。结果表明,与单纯依靠斜拉杆、钢管或摩擦阻尼器相比,方案 4 将钢管和摩擦阻尼器结合使用时,车库结构具有更好的抗震性能。方案 4 对整体最大变形响应、Y 方向最大变形响应、顶点加速度响应和底部剪切响应的抑制率分别高达 61.27%、22.12%、56.07% 和 12.84%。这一改进大大提高了车库的抗震稳定性,为推动垂直循环立体车库的发展和市场推广提供了有价值的理论参考。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Research on seismic suppression performance of vertical circulation stereo garage based on friction damper and steel pipe
The conventional vertical circulation stereo garage is susceptible to deformation and instability when subjected to extreme seismic loads and complex working conditions. The present study introduces the combination arrangement of steel pipe and friction damper to optimize vertical circulation stereo garage while also investigating their seismic suppression performance under three representative seismic waves (EL‐CNENTRO, TH1TG025(TH), and RH1TG025(RH)). The results showed that the garage structure hasbetter seismic suppression performance when the combination of steel pipes and friction dampers is applied in Scheme 4 compared to relying solely on diagonal tie rod, steel pipe or friction damper. And Scheme 4 achieves inhibition rates of up to 61.27%, 22.12%, 56.07%, and 12.84% for overall maximum deformation response, maximum Y‐direction deformation response, vertex acceleration response, and bottom shear response, respectively. This enhancement significantly improves the garage's seismic stability, providing valuable theoretical references for advancing the development and market promotion of vertical circulation stereo garages.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Analysis of seismic damage and seismic capacity of the structure of the ultrahigh pagoda Enhancing Concrete Performance with Waste Foundry Sand Using Ternary Blended Mixes of Ordinary Portland Cement, Silica Fume, and Ground Granulated Blast Furnace Slag An improved Chinese load code method for the evaluation of wind‐induced base shear force on base‐isolated buildings Prediction of wind pressures on supertall buildings based on proper orthogonal decomposition and machine learning The fiber hinge model for unbonded post‐tensioned beam‐column connections
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1