更新 BIPM.RI(II)-K1.Co-57 放射性核素 57Co 的放射性活度测量比对,以纳入 2023 年 BEV 的结果(奥地利)

IF 2.1 3区 工程技术 Q2 INSTRUMENTS & INSTRUMENTATION Metrologia Pub Date : 2024-08-19 DOI:10.1088/0026-1394/61/1a/06011
Romain Coulon, Carine Michotte, Sammy Courte, Manuel Nonis, Vincent Gressier, Robert Brettner-Messler, Patrick Lobner, Isabelle Mercedes Taschwer
{"title":"更新 BIPM.RI(II)-K1.Co-57 放射性核素 57Co 的放射性活度测量比对,以纳入 2023 年 BEV 的结果(奥地利)","authors":"Romain Coulon, Carine Michotte, Sammy Courte, Manuel Nonis, Vincent Gressier, Robert Brettner-Messler, Patrick Lobner, Isabelle Mercedes Taschwer","doi":"10.1088/0026-1394/61/1a/06011","DOIUrl":null,"url":null,"abstract":"<title>Main text</title>Since 1976, 20 laboratories have submitted 59 samples of <sup>57</sup>Co to the International Reference System (SIR) for activity comparison at the Bureau International des Poids et Mesures (BIPM), with comparison identifier BIPM.RI(II)-K1.Co-57. Recently, the BEV (Austria) participated in the comparison. The degrees of equivalence between each equivalent activity measured in the SIR or linked to the SIR from the CCRI(II)-S6.Co-57 comparison have been calculated and the results are given in the form of a table. A graphical representation is also given.To reach the main text of this paper, click on <ext-link xlink:href=\"https://www.bipm.org/documents/d/guest/bipm-ri-ii-k1-co-57_bev_2023\" xlink:type=\"simple\">Final Report</ext-link>. Note that this text is that which appears in Appendix B of the BIPM key comparison database <ext-link xlink:href=\"https://www.bipm.org/kcdb/\" xlink:type=\"simple\">https://www.bipm.org/kcdb/</ext-link>.The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).","PeriodicalId":18444,"journal":{"name":"Metrologia","volume":null,"pages":null},"PeriodicalIF":2.1000,"publicationDate":"2024-08-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Update of the BIPM comparison BIPM.RI(II)-K1.Co-57 of activity measurements of the radionuclide 57Co to include the 2023 result of the BEV (Austria)\",\"authors\":\"Romain Coulon, Carine Michotte, Sammy Courte, Manuel Nonis, Vincent Gressier, Robert Brettner-Messler, Patrick Lobner, Isabelle Mercedes Taschwer\",\"doi\":\"10.1088/0026-1394/61/1a/06011\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<title>Main text</title>Since 1976, 20 laboratories have submitted 59 samples of <sup>57</sup>Co to the International Reference System (SIR) for activity comparison at the Bureau International des Poids et Mesures (BIPM), with comparison identifier BIPM.RI(II)-K1.Co-57. Recently, the BEV (Austria) participated in the comparison. The degrees of equivalence between each equivalent activity measured in the SIR or linked to the SIR from the CCRI(II)-S6.Co-57 comparison have been calculated and the results are given in the form of a table. A graphical representation is also given.To reach the main text of this paper, click on <ext-link xlink:href=\\\"https://www.bipm.org/documents/d/guest/bipm-ri-ii-k1-co-57_bev_2023\\\" xlink:type=\\\"simple\\\">Final Report</ext-link>. Note that this text is that which appears in Appendix B of the BIPM key comparison database <ext-link xlink:href=\\\"https://www.bipm.org/kcdb/\\\" xlink:type=\\\"simple\\\">https://www.bipm.org/kcdb/</ext-link>.The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).\",\"PeriodicalId\":18444,\"journal\":{\"name\":\"Metrologia\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2024-08-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Metrologia\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1088/0026-1394/61/1a/06011\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"INSTRUMENTS & INSTRUMENTATION\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Metrologia","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1088/0026-1394/61/1a/06011","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0

摘要

正文自 1976 年以来,已有 20 个实验室向国际基准系统(SIR)提交了 59 个 57Co 样品,供国际计量局(BIPM)进行放射性活度比对,比对标识符为 BIPM.RI(II)-K1.Co-57。最近,奥地利 BEV 也参与了比对。通过 CCRI(II)-S6.Co-57 比对,计算了在 SIR 中测量的或与 SIR 相关联的每种等效活度之间的等效度,并以表格形式给出了结果。如需阅读本文正文,请点击 "最终报告"。请注意,本文为 BIPM 关键对比数据库附录 B 中的内容 https://www.bipm.org/kcdb/.The 根据 CIPM 互认安排 (CIPM MRA) 的规定,最终报告已经过同行评审,并获准由 CCRI 发布。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Update of the BIPM comparison BIPM.RI(II)-K1.Co-57 of activity measurements of the radionuclide 57Co to include the 2023 result of the BEV (Austria)
Main textSince 1976, 20 laboratories have submitted 59 samples of 57Co to the International Reference System (SIR) for activity comparison at the Bureau International des Poids et Mesures (BIPM), with comparison identifier BIPM.RI(II)-K1.Co-57. Recently, the BEV (Austria) participated in the comparison. The degrees of equivalence between each equivalent activity measured in the SIR or linked to the SIR from the CCRI(II)-S6.Co-57 comparison have been calculated and the results are given in the form of a table. A graphical representation is also given.To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/.The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Metrologia
Metrologia 工程技术-物理:应用
CiteScore
2.80
自引率
25.00%
发文量
137
审稿时长
12 months
期刊介绍: Published 6 times per year, Metrologia covers the fundamentals of measurements, particularly those dealing with the seven base units of the International System of Units (metre, kilogram, second, ampere, kelvin, candela, mole) or proposals to replace them. The journal also publishes papers that contribute to the solution of difficult measurement problems and improve the accuracy of derived units and constants that are of fundamental importance to physics. In addition to regular papers, the journal publishes review articles, issues devoted to single topics of timely interest and occasional conference proceedings. Letters to the Editor and Short Communications (generally three pages or less) are also considered.
期刊最新文献
A robust time scale for space applications using the student’s t-distribution A digital four-arm bridge for the comparison of resistance with capacitance Traceable characterisation of fibre-coupled single-photon detectors An emf-temperature reference function for Pt–20%Rh versus Pt thermocouples in the temperature range of 0 °C to 1100 °C Phase reconstruction by phase shift estimation with reliable parameter minimization
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1