用于核医学中放射性同位素在线监测的可穿戴 Perovskite 薄膜

Laura Basiricò, Matteo Verdi, Andrea Ciavatti, Lorenzo Piergallini, Elisa Grassi, Federica Fioroni, Lorenzo Margotti, Nicolò Tosi, Valentina Cicero, Alessandro Montanari, Mauro Iori, Beatrice Fraboni
{"title":"用于核医学中放射性同位素在线监测的可穿戴 Perovskite 薄膜","authors":"Laura Basiricò, Matteo Verdi, Andrea Ciavatti, Lorenzo Piergallini, Elisa Grassi, Federica Fioroni, Lorenzo Margotti, Nicolò Tosi, Valentina Cicero, Alessandro Montanari, Mauro Iori, Beatrice Fraboni","doi":"10.1002/admt.202401111","DOIUrl":null,"url":null,"abstract":"On-line in situ monitoring of radiation emitted by radiotracers during intravenous injection is of crucial importance for the safety of patients and personnel involved in nuclear medicine treatments and analysis. The aim of this work is to assess wearable perovskite ionizing radiation detectors for such application. With this purpose pixelated direct detector based on thin films of 2D layered perovskite PEA<sub>2</sub>PbBr<sub>4</sub> are tested for the monitoring of gamma-rays emitted by <sup>18</sup>F radiopharmaceutical under different experimental conditions. The wearable detector is here demonstrated being able to detect in real-time the gamma-rays emitted by annihilation of <sup>18</sup>F radiotracer. Its reliability is assessed by <sup>18</sup>F half-life measurement with a maximum accuracy deviation within 8%. The detector also successes in its validation for the foreseen application, demonstrating able to monitor in real-time the whole injection process and extravasation event.","PeriodicalId":7200,"journal":{"name":"Advanced Materials & Technologies","volume":"15 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-08-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Wearable Perovskite Films for On-Line Monitoring of Radiotracers in Nuclear Medicine\",\"authors\":\"Laura Basiricò, Matteo Verdi, Andrea Ciavatti, Lorenzo Piergallini, Elisa Grassi, Federica Fioroni, Lorenzo Margotti, Nicolò Tosi, Valentina Cicero, Alessandro Montanari, Mauro Iori, Beatrice Fraboni\",\"doi\":\"10.1002/admt.202401111\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"On-line in situ monitoring of radiation emitted by radiotracers during intravenous injection is of crucial importance for the safety of patients and personnel involved in nuclear medicine treatments and analysis. The aim of this work is to assess wearable perovskite ionizing radiation detectors for such application. With this purpose pixelated direct detector based on thin films of 2D layered perovskite PEA<sub>2</sub>PbBr<sub>4</sub> are tested for the monitoring of gamma-rays emitted by <sup>18</sup>F radiopharmaceutical under different experimental conditions. The wearable detector is here demonstrated being able to detect in real-time the gamma-rays emitted by annihilation of <sup>18</sup>F radiotracer. Its reliability is assessed by <sup>18</sup>F half-life measurement with a maximum accuracy deviation within 8%. The detector also successes in its validation for the foreseen application, demonstrating able to monitor in real-time the whole injection process and extravasation event.\",\"PeriodicalId\":7200,\"journal\":{\"name\":\"Advanced Materials & Technologies\",\"volume\":\"15 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-08-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Advanced Materials & Technologies\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1002/admt.202401111\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advanced Materials & Technologies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/admt.202401111","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

对放射性同位素在静脉注射过程中发出的辐射进行在线原位监测,对参与核医学治疗和分析的病人和工作人员的安全至关重要。这项工作的目的是评估用于此类应用的可穿戴式包晶电离辐射探测器。为此,对基于二维层状包晶 PEA2PbBr4 薄膜的像素化直接探测器进行了测试,以监测 18F 放射性药物在不同实验条件下发射的伽马射线。实验证明,这种可穿戴探测器能够实时检测到 18F 放射性示踪剂湮灭所发射的伽马射线。通过 18F 半衰期测量对其可靠性进行了评估,最大精度偏差在 8%以内。该探测器还成功通过了预期应用的验证,证明能够实时监测整个注射过程和外渗事件。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Wearable Perovskite Films for On-Line Monitoring of Radiotracers in Nuclear Medicine
On-line in situ monitoring of radiation emitted by radiotracers during intravenous injection is of crucial importance for the safety of patients and personnel involved in nuclear medicine treatments and analysis. The aim of this work is to assess wearable perovskite ionizing radiation detectors for such application. With this purpose pixelated direct detector based on thin films of 2D layered perovskite PEA2PbBr4 are tested for the monitoring of gamma-rays emitted by 18F radiopharmaceutical under different experimental conditions. The wearable detector is here demonstrated being able to detect in real-time the gamma-rays emitted by annihilation of 18F radiotracer. Its reliability is assessed by 18F half-life measurement with a maximum accuracy deviation within 8%. The detector also successes in its validation for the foreseen application, demonstrating able to monitor in real-time the whole injection process and extravasation event.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Plasma-Generated Luminescent Coatings: Innovations in Thermal Sensitivity and Corrosion Resistance Deep-Learning-Assisted Triboelectric Whisker Sensor Array for Real-Time Motion Sensing of Unmanned Underwater Vehicle Spectral Analysis on Color Detection Sharpness of Animal Vision toward Polychromatic Vision System Evaporated Copper-Based Perovskite Dynamic Memristors for Reservoir Computing Systems Hydrocarbon-Based Ionomer/PTFE-Reinforced Composite Membrane Through Multibar Coating Technique for Durable Fuel Cells
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1