用于光谱多重生物测定的平场透镜光栅微光谱仪

Gi Beom Kim, Jung‐Woo Park, Jaehun Jeon, Hyejeong Jeong, Eun‐Sil Yu, Ki‐Hun Jeong
{"title":"用于光谱多重生物测定的平场透镜光栅微光谱仪","authors":"Gi Beom Kim, Jung‐Woo Park, Jaehun Jeon, Hyejeong Jeong, Eun‐Sil Yu, Ki‐Hun Jeong","doi":"10.1002/admt.202401151","DOIUrl":null,"url":null,"abstract":"Spectroscopic multiplex bioassay allows the rapid and simultaneous detection of various biomarkers in biomedical applications. The high cost and bulky configuration of conventional spectrometers hinder the decentralization of biomedical instruments for point‐of‐care diagnostics. Here a flat‐field lens grating‐based microspectrometer (FLG‐µSPEC) is reported for continuous detection of multi‐target nucleic acid amplification. FLG‐µSPEC features the vertical integration of microslit, integrated flat‐field lens and transmission grating (FLG), concave mirror, and CMOS line sensor. FLG effectively corrects the field curvature by flattening the focal plane of dispersed wavelengths and also facilitates compact module packaging. FLG‐µSPEC module is precisely assembled into a dimension of 10 mm × 16 mm × 10 mm. The average spectral resolution exhibits 3.4 ± 0.9 nm over an operating range of 500 to 950 nm. A spectral detection system utilizing FLG‐µSPEC demonstrates the amplification of lambda DNA (𝜆‐DNA) for each target, exhibiting a high correlation with the obtained result from a conventional real‐time PCR (qPCR) machine. Furthermore, multiplex qPCR analysis using FLG‐µSPEC and spectral deconvolution successfully demonstrates simultaneous and accurate quantification of three different targets. The FLG‐µSPEC module offers diverse on‐demand analytical applications, including not only multiplex bioassay but also environmental monitoring.","PeriodicalId":7200,"journal":{"name":"Advanced Materials & Technologies","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-09-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Flat‐Field Lens Grating Microspectrometer for Spectroscopic Multiplex Bioassay\",\"authors\":\"Gi Beom Kim, Jung‐Woo Park, Jaehun Jeon, Hyejeong Jeong, Eun‐Sil Yu, Ki‐Hun Jeong\",\"doi\":\"10.1002/admt.202401151\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Spectroscopic multiplex bioassay allows the rapid and simultaneous detection of various biomarkers in biomedical applications. The high cost and bulky configuration of conventional spectrometers hinder the decentralization of biomedical instruments for point‐of‐care diagnostics. Here a flat‐field lens grating‐based microspectrometer (FLG‐µSPEC) is reported for continuous detection of multi‐target nucleic acid amplification. FLG‐µSPEC features the vertical integration of microslit, integrated flat‐field lens and transmission grating (FLG), concave mirror, and CMOS line sensor. FLG effectively corrects the field curvature by flattening the focal plane of dispersed wavelengths and also facilitates compact module packaging. FLG‐µSPEC module is precisely assembled into a dimension of 10 mm × 16 mm × 10 mm. The average spectral resolution exhibits 3.4 ± 0.9 nm over an operating range of 500 to 950 nm. A spectral detection system utilizing FLG‐µSPEC demonstrates the amplification of lambda DNA (𝜆‐DNA) for each target, exhibiting a high correlation with the obtained result from a conventional real‐time PCR (qPCR) machine. Furthermore, multiplex qPCR analysis using FLG‐µSPEC and spectral deconvolution successfully demonstrates simultaneous and accurate quantification of three different targets. The FLG‐µSPEC module offers diverse on‐demand analytical applications, including not only multiplex bioassay but also environmental monitoring.\",\"PeriodicalId\":7200,\"journal\":{\"name\":\"Advanced Materials & Technologies\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-09-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Advanced Materials & Technologies\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1002/admt.202401151\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advanced Materials & Technologies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/admt.202401151","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

光谱多重生物分析法可在生物医学应用中快速、同步地检测各种生物标记物。传统光谱仪的高成本和笨重结构阻碍了用于床旁诊断的生物医学仪器的分散化。本文报告了一种基于平场透镜光栅的微光谱仪(FLG-µSPEC),用于多目标核酸扩增的连续检测。FLG-µSPEC 的特点是垂直集成微缝、集成平场透镜和透射光栅(FLG)、凹面镜和 CMOS 线传感器。FLG 通过使分散波长的焦平面平坦化,有效地校正了场曲率,同时也有利于模块的紧凑封装。FLG-µSPEC 模块可精确组装成 10 毫米 × 16 毫米 × 10 毫米的尺寸。在 500 至 950 nm 的工作范围内,平均光谱分辨率为 3.4 ± 0.9 nm。利用 FLG-µSPEC 的光谱检测系统对每个目标进行了λ DNA(𝜆-DNA)扩增,与传统实时 PCR(qPCR)设备获得的结果具有很高的相关性。此外,利用 FLG-µSPEC 和光谱解卷积技术进行的多重 qPCR 分析成功地展示了对三个不同靶标的同步精确定量。FLG-µSPEC 模块可提供多种按需分析应用,不仅包括多重生物分析,还包括环境监测。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Flat‐Field Lens Grating Microspectrometer for Spectroscopic Multiplex Bioassay
Spectroscopic multiplex bioassay allows the rapid and simultaneous detection of various biomarkers in biomedical applications. The high cost and bulky configuration of conventional spectrometers hinder the decentralization of biomedical instruments for point‐of‐care diagnostics. Here a flat‐field lens grating‐based microspectrometer (FLG‐µSPEC) is reported for continuous detection of multi‐target nucleic acid amplification. FLG‐µSPEC features the vertical integration of microslit, integrated flat‐field lens and transmission grating (FLG), concave mirror, and CMOS line sensor. FLG effectively corrects the field curvature by flattening the focal plane of dispersed wavelengths and also facilitates compact module packaging. FLG‐µSPEC module is precisely assembled into a dimension of 10 mm × 16 mm × 10 mm. The average spectral resolution exhibits 3.4 ± 0.9 nm over an operating range of 500 to 950 nm. A spectral detection system utilizing FLG‐µSPEC demonstrates the amplification of lambda DNA (𝜆‐DNA) for each target, exhibiting a high correlation with the obtained result from a conventional real‐time PCR (qPCR) machine. Furthermore, multiplex qPCR analysis using FLG‐µSPEC and spectral deconvolution successfully demonstrates simultaneous and accurate quantification of three different targets. The FLG‐µSPEC module offers diverse on‐demand analytical applications, including not only multiplex bioassay but also environmental monitoring.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Plasma-Generated Luminescent Coatings: Innovations in Thermal Sensitivity and Corrosion Resistance Deep-Learning-Assisted Triboelectric Whisker Sensor Array for Real-Time Motion Sensing of Unmanned Underwater Vehicle Spectral Analysis on Color Detection Sharpness of Animal Vision toward Polychromatic Vision System Evaporated Copper-Based Perovskite Dynamic Memristors for Reservoir Computing Systems Hydrocarbon-Based Ionomer/PTFE-Reinforced Composite Membrane Through Multibar Coating Technique for Durable Fuel Cells
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1