用于单粒子质谱中两步解吸/电离过程的固态红外激光器

IF 3.2 3区 地球科学 Q2 METEOROLOGY & ATMOSPHERIC SCIENCES Atmospheric Measurement Techniques Pub Date : 2024-09-12 DOI:10.5194/egusphere-2024-2587
Marco Schmidt, Haseeb Hakkim, Lukas Anders, Aleksandrs Kalamašņikovs, Thomas Kröger-Badge, Robert Irsig, Norbert Graf, Reinhard Kelnberger, Johannes Passig, Ralf Zimmermann
{"title":"用于单粒子质谱中两步解吸/电离过程的固态红外激光器","authors":"Marco Schmidt, Haseeb Hakkim, Lukas Anders, Aleksandrs Kalamašņikovs, Thomas Kröger-Badge, Robert Irsig, Norbert Graf, Reinhard Kelnberger, Johannes Passig, Ralf Zimmermann","doi":"10.5194/egusphere-2024-2587","DOIUrl":null,"url":null,"abstract":"<strong>Abstract.</strong> Recent advancements in single-particle mass spectrometry (SPMS) have enabled the detection of aromatic hydrocarbons at the individual particle level in conjunction with inorganic/refractory particle components. However, the laser desorption (LD) of organic material from particles prior to their ionization in a two-step process necessitates pulsed infrared lasers with adequate pulse energy that can be irregularly triggered on detected particles. Pulsed CO<sub>2</sub> lasers with a 10.6 µm wavelength have been traditionally utilized, yet these lasers are bulky, costly, and require regular maintenance, including gas exchange or a continuous laser gas supply. In this study, we present the application of a prototype solid-state laser based on an erbium-doped yttrium aluminum garnet (Er:YAG) crystal, emitting long pulses of 200 µs at 3 µm wavelength as a compact, cost-effective, and user-friendly alternative for LD. We directly compared the new laser with a commonly used CO<sub>2</sub> laser and found similar performance in LD for both laboratory particles and ambient air experiments. With the exception of slightly increased fragmentation observed with the CO<sub>2</sub> laser due to its beam profile, no qualitative differences were noted in the resulting mass spectra. Additionally, we compared the novel two-step ionization scheme for the combined detection of aromatic molecules and inorganics with conventional single-step laser desorption/ionization (LDI) for the detection of polycyclic aromatic hydrocarbons (PAH) in laboratory and field experiments. The combined methods demonstrated superior performance in the detection of PAHs, for both the CO<sub>2</sub> and the new Er:YAG laser. In addition to its higher sensitivity and lower fragmentation for PAHs when compared to single-step LDI, it is less dependent on the particle matrix, sharing the benefits of traditional two-step methods but extending its capability to combine PAH measurements with the LDI-based detection of inorganic particle compounds.","PeriodicalId":8619,"journal":{"name":"Atmospheric Measurement Techniques","volume":"217 1","pages":""},"PeriodicalIF":3.2000,"publicationDate":"2024-09-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A solid-state IR laser for two-step desorption/ionization processes in single-particle mass spectrometry\",\"authors\":\"Marco Schmidt, Haseeb Hakkim, Lukas Anders, Aleksandrs Kalamašņikovs, Thomas Kröger-Badge, Robert Irsig, Norbert Graf, Reinhard Kelnberger, Johannes Passig, Ralf Zimmermann\",\"doi\":\"10.5194/egusphere-2024-2587\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<strong>Abstract.</strong> Recent advancements in single-particle mass spectrometry (SPMS) have enabled the detection of aromatic hydrocarbons at the individual particle level in conjunction with inorganic/refractory particle components. However, the laser desorption (LD) of organic material from particles prior to their ionization in a two-step process necessitates pulsed infrared lasers with adequate pulse energy that can be irregularly triggered on detected particles. Pulsed CO<sub>2</sub> lasers with a 10.6 µm wavelength have been traditionally utilized, yet these lasers are bulky, costly, and require regular maintenance, including gas exchange or a continuous laser gas supply. In this study, we present the application of a prototype solid-state laser based on an erbium-doped yttrium aluminum garnet (Er:YAG) crystal, emitting long pulses of 200 µs at 3 µm wavelength as a compact, cost-effective, and user-friendly alternative for LD. We directly compared the new laser with a commonly used CO<sub>2</sub> laser and found similar performance in LD for both laboratory particles and ambient air experiments. With the exception of slightly increased fragmentation observed with the CO<sub>2</sub> laser due to its beam profile, no qualitative differences were noted in the resulting mass spectra. Additionally, we compared the novel two-step ionization scheme for the combined detection of aromatic molecules and inorganics with conventional single-step laser desorption/ionization (LDI) for the detection of polycyclic aromatic hydrocarbons (PAH) in laboratory and field experiments. The combined methods demonstrated superior performance in the detection of PAHs, for both the CO<sub>2</sub> and the new Er:YAG laser. In addition to its higher sensitivity and lower fragmentation for PAHs when compared to single-step LDI, it is less dependent on the particle matrix, sharing the benefits of traditional two-step methods but extending its capability to combine PAH measurements with the LDI-based detection of inorganic particle compounds.\",\"PeriodicalId\":8619,\"journal\":{\"name\":\"Atmospheric Measurement Techniques\",\"volume\":\"217 1\",\"pages\":\"\"},\"PeriodicalIF\":3.2000,\"publicationDate\":\"2024-09-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Atmospheric Measurement Techniques\",\"FirstCategoryId\":\"89\",\"ListUrlMain\":\"https://doi.org/10.5194/egusphere-2024-2587\",\"RegionNum\":3,\"RegionCategory\":\"地球科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"METEOROLOGY & ATMOSPHERIC SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Atmospheric Measurement Techniques","FirstCategoryId":"89","ListUrlMain":"https://doi.org/10.5194/egusphere-2024-2587","RegionNum":3,"RegionCategory":"地球科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"METEOROLOGY & ATMOSPHERIC SCIENCES","Score":null,"Total":0}
引用次数: 0

摘要

摘要。单颗粒质谱法(SPMS)的最新进展使我们能够在单颗粒水平上检测芳香烃以及无机/耐火颗粒成分。然而,在两步法过程中,先用激光解吸(LD)颗粒中的有机物,然后再将其离子化,这就要求脉冲红外激光器具有足够的脉冲能量,并能在检测到的颗粒上不规则地触发。传统上使用的是波长为 10.6 µm 的脉冲 CO2 激光器,但这些激光器体积庞大、成本高昂,而且需要定期维护,包括气体交换或持续的激光气体供应。在本研究中,我们介绍了一种基于掺铒钇铝石榴石(Er:YAG)晶体的固态激光器原型的应用,这种激光器能在 3 µm 波长下发射 200 µs 的长脉冲,是一种结构紧凑、成本低廉、使用方便的 LD 替代品。我们将这种新型激光器与常用的 CO2 激光器进行了直接比较,发现在实验室颗粒和环境空气实验中,两者的激光雷达性能相似。除了 CO2 激光器的光束轮廓导致碎裂率略有增加外,所产生的质谱图没有发现质的差异。此外,我们还比较了在实验室和现场实验中联合检测芳香分子和无机物的新型两步电离方案与检测多环芳烃(PAH)的传统单步激光解吸/电离(LDI)方案。二氧化碳激光器和新型 Er:YAG 激光器的组合方法在多环芳烃检测方面都表现出了卓越的性能。与单步 LDI 相比,除了对 PAHs 的灵敏度更高、破碎率更低之外,该方法对颗粒基质的依赖性也更小,不仅分享了传统两步法的优点,还将其能力扩展到将 PAH 测量与基于 LDI 的无机颗粒化合物检测相结合。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A solid-state IR laser for two-step desorption/ionization processes in single-particle mass spectrometry
Abstract. Recent advancements in single-particle mass spectrometry (SPMS) have enabled the detection of aromatic hydrocarbons at the individual particle level in conjunction with inorganic/refractory particle components. However, the laser desorption (LD) of organic material from particles prior to their ionization in a two-step process necessitates pulsed infrared lasers with adequate pulse energy that can be irregularly triggered on detected particles. Pulsed CO2 lasers with a 10.6 µm wavelength have been traditionally utilized, yet these lasers are bulky, costly, and require regular maintenance, including gas exchange or a continuous laser gas supply. In this study, we present the application of a prototype solid-state laser based on an erbium-doped yttrium aluminum garnet (Er:YAG) crystal, emitting long pulses of 200 µs at 3 µm wavelength as a compact, cost-effective, and user-friendly alternative for LD. We directly compared the new laser with a commonly used CO2 laser and found similar performance in LD for both laboratory particles and ambient air experiments. With the exception of slightly increased fragmentation observed with the CO2 laser due to its beam profile, no qualitative differences were noted in the resulting mass spectra. Additionally, we compared the novel two-step ionization scheme for the combined detection of aromatic molecules and inorganics with conventional single-step laser desorption/ionization (LDI) for the detection of polycyclic aromatic hydrocarbons (PAH) in laboratory and field experiments. The combined methods demonstrated superior performance in the detection of PAHs, for both the CO2 and the new Er:YAG laser. In addition to its higher sensitivity and lower fragmentation for PAHs when compared to single-step LDI, it is less dependent on the particle matrix, sharing the benefits of traditional two-step methods but extending its capability to combine PAH measurements with the LDI-based detection of inorganic particle compounds.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Atmospheric Measurement Techniques
Atmospheric Measurement Techniques METEOROLOGY & ATMOSPHERIC SCIENCES-
CiteScore
7.10
自引率
18.40%
发文量
331
审稿时长
3 months
期刊介绍: Atmospheric Measurement Techniques (AMT) is an international scientific journal dedicated to the publication and discussion of advances in remote sensing, in-situ and laboratory measurement techniques for the constituents and properties of the Earth’s atmosphere. The main subject areas comprise the development, intercomparison and validation of measurement instruments and techniques of data processing and information retrieval for gases, aerosols, and clouds. The manuscript types considered for peer-reviewed publication are research articles, review articles, and commentaries.
期刊最新文献
Analyzing the chemical composition, morphology and size of ice-nucleating particles by coupling a scanning electron microscope to an offline diffusion chamber Wet-Radome Attenuation in ARM Cloud Radars and Its Utilization in Radar Calibration Using Disdrometer Measurements Chilean Observation Network De MeteOr Radars (CONDOR): Multi-Static System Configuration & Wind Comparison with Co-located Lidar Benchmarking KDP in Rainfall: A Quantitative Assessment of Estimation Algorithms Using C-Band Weather Radar Observations Advances in OH reactivity instruments for airborne field measurements
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1