制备工艺对 NaMgF3:Dy,Eu 的光致发光(OSL)和热致发光(TL)特性的影响研究

IF 1.6 3区 物理与天体物理 Q2 NUCLEAR SCIENCE & TECHNOLOGY Radiation Measurements Pub Date : 2024-09-10 DOI:10.1016/j.radmeas.2024.107297
Siyuan Zhang, Kaiyong Tang, Li Fu, Mo Zhou, Haijun Fan, Yan Zeng, Zhiyuan Li
{"title":"制备工艺对 NaMgF3:Dy,Eu 的光致发光(OSL)和热致发光(TL)特性的影响研究","authors":"Siyuan Zhang,&nbsp;Kaiyong Tang,&nbsp;Li Fu,&nbsp;Mo Zhou,&nbsp;Haijun Fan,&nbsp;Yan Zeng,&nbsp;Zhiyuan Li","doi":"10.1016/j.radmeas.2024.107297","DOIUrl":null,"url":null,"abstract":"<div><p>OSL fading with storage time after irradiation remains a major obstacle in the development of ideal OSL materials. Dy and Eu co-doped NaMgF<sub>3</sub> are attractive candidates for various rare earth doped matrix materials. In this study, NaMgF<sub>3</sub>:Dy,Eu was synthesized by a solid-state reaction, and the effects of heating temperature, duration, atmosphere, and cooling rate on XRD, TL and OSL properties were studied. A simple, safe, efficient, and time-saving solid-state reaction was identified as a potential method for the preparation of NaMgF<sub>3</sub>:Dy,Eu, which could be optimally prepared by heating at 750 °C for 2 h under nitrogen atmosphere (2 l/min) followed by rapid cooling. The results show that NaMgF<sub>3</sub>:Dy,Eu has a more stable OSL response and an excellent TL glow curve, with only a 0.4% decrease in the OSL signal read after 1 d of dose irradiation compared to that immediately after irradiation, and a high main TL peak at ∼320 °C. It has been indicated the OSL signal in this material seems to be strongly related to the main TL peak. The material has a considerable OSL sensitivity and decay rate than the Luxel Detector. NaMgF<sub>3</sub>:Dy,Eu will have a promising future in the field of OSL dosimetry due to its near tissue equivalence, low OSL fading without preheating, fast OSL decay rate, and predictable and easily reusable dose elimination.</p></div>","PeriodicalId":21055,"journal":{"name":"Radiation Measurements","volume":"178 ","pages":"Article 107297"},"PeriodicalIF":1.6000,"publicationDate":"2024-09-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Study on the effects of preparation processes on OSL and TL properties of NaMgF3:Dy,Eu\",\"authors\":\"Siyuan Zhang,&nbsp;Kaiyong Tang,&nbsp;Li Fu,&nbsp;Mo Zhou,&nbsp;Haijun Fan,&nbsp;Yan Zeng,&nbsp;Zhiyuan Li\",\"doi\":\"10.1016/j.radmeas.2024.107297\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>OSL fading with storage time after irradiation remains a major obstacle in the development of ideal OSL materials. Dy and Eu co-doped NaMgF<sub>3</sub> are attractive candidates for various rare earth doped matrix materials. In this study, NaMgF<sub>3</sub>:Dy,Eu was synthesized by a solid-state reaction, and the effects of heating temperature, duration, atmosphere, and cooling rate on XRD, TL and OSL properties were studied. A simple, safe, efficient, and time-saving solid-state reaction was identified as a potential method for the preparation of NaMgF<sub>3</sub>:Dy,Eu, which could be optimally prepared by heating at 750 °C for 2 h under nitrogen atmosphere (2 l/min) followed by rapid cooling. The results show that NaMgF<sub>3</sub>:Dy,Eu has a more stable OSL response and an excellent TL glow curve, with only a 0.4% decrease in the OSL signal read after 1 d of dose irradiation compared to that immediately after irradiation, and a high main TL peak at ∼320 °C. It has been indicated the OSL signal in this material seems to be strongly related to the main TL peak. The material has a considerable OSL sensitivity and decay rate than the Luxel Detector. NaMgF<sub>3</sub>:Dy,Eu will have a promising future in the field of OSL dosimetry due to its near tissue equivalence, low OSL fading without preheating, fast OSL decay rate, and predictable and easily reusable dose elimination.</p></div>\",\"PeriodicalId\":21055,\"journal\":{\"name\":\"Radiation Measurements\",\"volume\":\"178 \",\"pages\":\"Article 107297\"},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2024-09-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Radiation Measurements\",\"FirstCategoryId\":\"101\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1350448724002452\",\"RegionNum\":3,\"RegionCategory\":\"物理与天体物理\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"NUCLEAR SCIENCE & TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiation Measurements","FirstCategoryId":"101","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1350448724002452","RegionNum":3,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"NUCLEAR SCIENCE & TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

辐照后,OSL 会随储存时间而衰减,这仍然是开发理想 OSL 材料的主要障碍。Dy和Eu共掺杂的NaMgF3是各种稀土掺杂基体材料的理想候选材料。本研究通过固态反应合成了 NaMgF3:Dy,Eu,并研究了加热温度、持续时间、气氛和冷却速率对 XRD、TL 和 OSL 性能的影响。结果表明,在氮气环境(2 升/分钟)下于 750 ℃加热 2 小时,然后快速冷却,可以制备出最佳的 NaMgF3:Dy,Eu。结果表明,NaMgF3:Dy,Eu 具有更稳定的 OSL 响应和出色的 TL 辉光曲线,在剂量辐照 1 d 后读取的 OSL 信号与辐照后立即读取的信号相比仅下降了 0.4%,并且在 ∼320 °C 处具有较高的 TL 主峰。这表明该材料中的 OSL 信号似乎与主 TL 峰密切相关。与 Luxel 探测器相比,该材料具有相当高的 OSL 灵敏度和衰减率。NaMgF3:Dy,Eu因其接近组织等效性、无需预热的低OSL衰减、快速的OSL衰减率以及可预测和易于重复使用的剂量消除,在OSL剂量测定领域前景广阔。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Study on the effects of preparation processes on OSL and TL properties of NaMgF3:Dy,Eu

OSL fading with storage time after irradiation remains a major obstacle in the development of ideal OSL materials. Dy and Eu co-doped NaMgF3 are attractive candidates for various rare earth doped matrix materials. In this study, NaMgF3:Dy,Eu was synthesized by a solid-state reaction, and the effects of heating temperature, duration, atmosphere, and cooling rate on XRD, TL and OSL properties were studied. A simple, safe, efficient, and time-saving solid-state reaction was identified as a potential method for the preparation of NaMgF3:Dy,Eu, which could be optimally prepared by heating at 750 °C for 2 h under nitrogen atmosphere (2 l/min) followed by rapid cooling. The results show that NaMgF3:Dy,Eu has a more stable OSL response and an excellent TL glow curve, with only a 0.4% decrease in the OSL signal read after 1 d of dose irradiation compared to that immediately after irradiation, and a high main TL peak at ∼320 °C. It has been indicated the OSL signal in this material seems to be strongly related to the main TL peak. The material has a considerable OSL sensitivity and decay rate than the Luxel Detector. NaMgF3:Dy,Eu will have a promising future in the field of OSL dosimetry due to its near tissue equivalence, low OSL fading without preheating, fast OSL decay rate, and predictable and easily reusable dose elimination.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Radiation Measurements
Radiation Measurements 工程技术-核科学技术
CiteScore
4.10
自引率
20.00%
发文量
116
审稿时长
48 days
期刊介绍: The journal seeks to publish papers that present advances in the following areas: spontaneous and stimulated luminescence (including scintillating materials, thermoluminescence, and optically stimulated luminescence); electron spin resonance of natural and synthetic materials; the physics, design and performance of radiation measurements (including computational modelling such as electronic transport simulations); the novel basic aspects of radiation measurement in medical physics. Studies of energy-transfer phenomena, track physics and microdosimetry are also of interest to the journal. Applications relevant to the journal, particularly where they present novel detection techniques, novel analytical approaches or novel materials, include: personal dosimetry (including dosimetric quantities, active/electronic and passive monitoring techniques for photon, neutron and charged-particle exposures); environmental dosimetry (including methodological advances and predictive models related to radon, but generally excluding local survey results of radon where the main aim is to establish the radiation risk to populations); cosmic and high-energy radiation measurements (including dosimetry, space radiation effects, and single event upsets); dosimetry-based archaeological and Quaternary dating; dosimetry-based approaches to thermochronometry; accident and retrospective dosimetry (including activation detectors), and dosimetry and measurements related to medical applications.
期刊最新文献
Photon energy estimation in diagnostic radiology using OSL dosimeters: Experimental validation and Monte Carlo simulations Review of real time 2D dosimetry in external radiotherapy: Advancements and techniques Exploration of dosimetry characteristics of PVA/MWCNT-OH nanocomposite for intraoperative electron radiotherapy Clinical evaluation of a new device for acceptance testing of Ru-106 plaques in ophthalmic brachytherapy Editorial Board
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1