{"title":"有机沉淀、电凝和电氧化联合处理厌氧处理棕榈油厂污水的性能","authors":"Peerawat Khongkliang, Kaewmada Chalearmkul, Kettawan Boonloh, Nunthakan Kanjanasombun, Tipaporn Darnsawat, Jarungwit Boonnorat, Abudukeremu Kadier, Putu Teta Prihartini Aryanti, Chantaraporn Phalakornkule","doi":"10.1007/s13201-024-02288-y","DOIUrl":null,"url":null,"abstract":"<div><p>Palm oil mill effluent (POME), wastewater generated from palm oil production, is known for its extremely high chemical oxygen demand and brownish color. Anaerobic digestion is the primary treatment method for POME in the palm oil industry; however, anaerobically treated POME has high concentrations of residual contaminants and color intensity. This study proposes an approach to treat anaerobically-treated POME in recycled water for industrial applications by integrating preliminary organic precipitation, electrocoagulation, and electrooxidation (EO). The EO process was optimized in terms of the current density, electrolysis time, electrode arrangement, and feed flow rate. At a current density of 60 mA/cm<sup>2</sup> and an electrolysis time of 9 min, the EO process with a graphite anode and stainless-steel cathode in the monopolar electrode configuration reduced the phenolic concentration and color in the preliminary-treated POME from 8.95 mg/L and 317.19 ADMI to 0.25 mg/L and 26.10 ADMI, respectively. Additionally, the EO process exhibited a 92.26% efficiency in lowering the ammonium-nitrogen content.</p></div>","PeriodicalId":8374,"journal":{"name":"Applied Water Science","volume":"14 10","pages":""},"PeriodicalIF":5.7000,"publicationDate":"2024-09-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://link.springer.com/content/pdf/10.1007/s13201-024-02288-y.pdf","citationCount":"0","resultStr":"{\"title\":\"Performance of combined organic precipitation, electrocoagulation, and electrooxidation in treating anaerobically treated palm oil mill effluents\",\"authors\":\"Peerawat Khongkliang, Kaewmada Chalearmkul, Kettawan Boonloh, Nunthakan Kanjanasombun, Tipaporn Darnsawat, Jarungwit Boonnorat, Abudukeremu Kadier, Putu Teta Prihartini Aryanti, Chantaraporn Phalakornkule\",\"doi\":\"10.1007/s13201-024-02288-y\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Palm oil mill effluent (POME), wastewater generated from palm oil production, is known for its extremely high chemical oxygen demand and brownish color. Anaerobic digestion is the primary treatment method for POME in the palm oil industry; however, anaerobically treated POME has high concentrations of residual contaminants and color intensity. This study proposes an approach to treat anaerobically-treated POME in recycled water for industrial applications by integrating preliminary organic precipitation, electrocoagulation, and electrooxidation (EO). The EO process was optimized in terms of the current density, electrolysis time, electrode arrangement, and feed flow rate. At a current density of 60 mA/cm<sup>2</sup> and an electrolysis time of 9 min, the EO process with a graphite anode and stainless-steel cathode in the monopolar electrode configuration reduced the phenolic concentration and color in the preliminary-treated POME from 8.95 mg/L and 317.19 ADMI to 0.25 mg/L and 26.10 ADMI, respectively. Additionally, the EO process exhibited a 92.26% efficiency in lowering the ammonium-nitrogen content.</p></div>\",\"PeriodicalId\":8374,\"journal\":{\"name\":\"Applied Water Science\",\"volume\":\"14 10\",\"pages\":\"\"},\"PeriodicalIF\":5.7000,\"publicationDate\":\"2024-09-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://link.springer.com/content/pdf/10.1007/s13201-024-02288-y.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Applied Water Science\",\"FirstCategoryId\":\"93\",\"ListUrlMain\":\"https://link.springer.com/article/10.1007/s13201-024-02288-y\",\"RegionNum\":3,\"RegionCategory\":\"环境科学与生态学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"WATER RESOURCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Applied Water Science","FirstCategoryId":"93","ListUrlMain":"https://link.springer.com/article/10.1007/s13201-024-02288-y","RegionNum":3,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"WATER RESOURCES","Score":null,"Total":0}
Performance of combined organic precipitation, electrocoagulation, and electrooxidation in treating anaerobically treated palm oil mill effluents
Palm oil mill effluent (POME), wastewater generated from palm oil production, is known for its extremely high chemical oxygen demand and brownish color. Anaerobic digestion is the primary treatment method for POME in the palm oil industry; however, anaerobically treated POME has high concentrations of residual contaminants and color intensity. This study proposes an approach to treat anaerobically-treated POME in recycled water for industrial applications by integrating preliminary organic precipitation, electrocoagulation, and electrooxidation (EO). The EO process was optimized in terms of the current density, electrolysis time, electrode arrangement, and feed flow rate. At a current density of 60 mA/cm2 and an electrolysis time of 9 min, the EO process with a graphite anode and stainless-steel cathode in the monopolar electrode configuration reduced the phenolic concentration and color in the preliminary-treated POME from 8.95 mg/L and 317.19 ADMI to 0.25 mg/L and 26.10 ADMI, respectively. Additionally, the EO process exhibited a 92.26% efficiency in lowering the ammonium-nitrogen content.