利用 MC-ICP-MS 和 Apex Omega 脱溶系统测量痕量钕和铪同位素(小于 10 纳克)的简化仪器方案

IF 3.1 2区 化学 Q2 CHEMISTRY, ANALYTICAL Journal of Analytical Atomic Spectrometry Pub Date : 2024-09-18 DOI:10.1039/d4ja00276h
Ting Zhou, Liang Qi, shenghua Liu, bo Zhou
{"title":"利用 MC-ICP-MS 和 Apex Omega 脱溶系统测量痕量钕和铪同位素(小于 10 纳克)的简化仪器方案","authors":"Ting Zhou, Liang Qi, shenghua Liu, bo Zhou","doi":"10.1039/d4ja00276h","DOIUrl":null,"url":null,"abstract":"We reported a simple technique allowing accurate and precise Nd and Hf isotope measurements of samples with low contents by the Neptune Plus MC-ICP-MS and Apex Omega membrane de-solvating system. By employing high sensitive Jet sample cone and X skimmer cone, our protocol achieved low oxide level (&lt;0.05 %) at high ion transmission (~880 V/ppm for Nd and 850 V/ppm for Hf) and was found to have little effect on the mass fractionation of Nd and Hf. This was accomplished by simple adjustments of the sweep gas of membrane de-solvating system and the sample gas of nebulizer. Instrumental sensitivities were enhanced by a factor exceeding tenfold, in comparison to those of the standard measurements by wet plasma. Long term measurements of 1 ng Nd solution standards yield 143Nd/144Nd ratios of 0.512117±0.000032 (2SD, n=24) and 0.512227±0.000036 (2SD, n=42) for Jndi-1 and JMC-Nd solutions respectively, while analysis of 1 ng JMC475 Hf gave 176Hf/177Hf ratios of 0.282163±0.000027 (2SD, n=21). These results are in agreements with their reference values. Potential interfering elements Ce and Sm are found to have insignificant influence on 143Nd/144Nd ratios. Lu and Yb have remarkable effect on 176Hf/177Hf ratios. Improved correction performance can be achieved by using Lu and Yb ratios obtained by analyzing pure Lu and Yb solutions. Five chemically purified rock reference materials are measured with the presented method and the results are consistent with their recommended values. Relative to other approaches, this protocol is rapid and accurate, and can be widely applied in Nd and Hf isotope analysis of samples with trace amounts of Nd and Hf (&lt;10 ng).","PeriodicalId":81,"journal":{"name":"Journal of Analytical Atomic Spectrometry","volume":null,"pages":null},"PeriodicalIF":3.1000,"publicationDate":"2024-09-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A simplified instrumental protocol for trace Nd and Hf isotope measurements (<10 ng) by MC-ICP-MS and Apex Omega de-solvating system\",\"authors\":\"Ting Zhou, Liang Qi, shenghua Liu, bo Zhou\",\"doi\":\"10.1039/d4ja00276h\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We reported a simple technique allowing accurate and precise Nd and Hf isotope measurements of samples with low contents by the Neptune Plus MC-ICP-MS and Apex Omega membrane de-solvating system. By employing high sensitive Jet sample cone and X skimmer cone, our protocol achieved low oxide level (&lt;0.05 %) at high ion transmission (~880 V/ppm for Nd and 850 V/ppm for Hf) and was found to have little effect on the mass fractionation of Nd and Hf. This was accomplished by simple adjustments of the sweep gas of membrane de-solvating system and the sample gas of nebulizer. Instrumental sensitivities were enhanced by a factor exceeding tenfold, in comparison to those of the standard measurements by wet plasma. Long term measurements of 1 ng Nd solution standards yield 143Nd/144Nd ratios of 0.512117±0.000032 (2SD, n=24) and 0.512227±0.000036 (2SD, n=42) for Jndi-1 and JMC-Nd solutions respectively, while analysis of 1 ng JMC475 Hf gave 176Hf/177Hf ratios of 0.282163±0.000027 (2SD, n=21). These results are in agreements with their reference values. Potential interfering elements Ce and Sm are found to have insignificant influence on 143Nd/144Nd ratios. Lu and Yb have remarkable effect on 176Hf/177Hf ratios. Improved correction performance can be achieved by using Lu and Yb ratios obtained by analyzing pure Lu and Yb solutions. Five chemically purified rock reference materials are measured with the presented method and the results are consistent with their recommended values. Relative to other approaches, this protocol is rapid and accurate, and can be widely applied in Nd and Hf isotope analysis of samples with trace amounts of Nd and Hf (&lt;10 ng).\",\"PeriodicalId\":81,\"journal\":{\"name\":\"Journal of Analytical Atomic Spectrometry\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.1000,\"publicationDate\":\"2024-09-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Analytical Atomic Spectrometry\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.1039/d4ja00276h\",\"RegionNum\":2,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Analytical Atomic Spectrometry","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1039/d4ja00276h","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

我们报告了一种简单的技术,利用 Neptune Plus MC-ICP-MS 和 Apex Omega 膜除溶系统,可对低含量样品进行精确的钕和铪同位素测量。通过采用高灵敏度的 Jet 样品锥和 X 收样锥,我们的方案在高离子传输(钕为 ~880 V/ppm,铪为 850 V/ppm)条件下实现了低氧化物含量(<0.05 %),并且发现对钕和铪的质量分馏影响很小。通过简单调整膜脱溶系统的扫气和雾化器的样品气,便可实现这一目标。与湿等离子体标准测量相比,仪器的灵敏度提高了十倍以上。对 1 毫微克钕溶液标准的长期测量结果显示,Jndi-1 和 JMC-Nd 溶液的 143Nd/144Nd 比率分别为 0.512117±0.000032 (2SD,n=24)和 0.512227±0.000036 (2SD,n=42);而对 1 毫微克 JMC475 Hf 的分析结果显示,176Hf/177Hf 比率为 0.282163±0.000027(2SD,n=21)。这些结果与参考值一致。潜在干扰元素 Ce 和 Sm 对 143Nd/144Nd 比率的影响不大。而 Lu 和 Yb 则对 176Hf/177Hf 比率有显著影响。通过分析纯的 Lu 和 Yb 溶液获得的 Lu 和 Yb 比率可以提高校正性能。使用所介绍的方法测量了五种化学纯化的岩石参考材料,结果与推荐值一致。与其他方法相比,该方法快速、准确,可广泛应用于含有痕量 Nd 和 Hf(<10 毫微克)的样品的 Nd 和 Hf 同位素分析。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A simplified instrumental protocol for trace Nd and Hf isotope measurements (<10 ng) by MC-ICP-MS and Apex Omega de-solvating system
We reported a simple technique allowing accurate and precise Nd and Hf isotope measurements of samples with low contents by the Neptune Plus MC-ICP-MS and Apex Omega membrane de-solvating system. By employing high sensitive Jet sample cone and X skimmer cone, our protocol achieved low oxide level (<0.05 %) at high ion transmission (~880 V/ppm for Nd and 850 V/ppm for Hf) and was found to have little effect on the mass fractionation of Nd and Hf. This was accomplished by simple adjustments of the sweep gas of membrane de-solvating system and the sample gas of nebulizer. Instrumental sensitivities were enhanced by a factor exceeding tenfold, in comparison to those of the standard measurements by wet plasma. Long term measurements of 1 ng Nd solution standards yield 143Nd/144Nd ratios of 0.512117±0.000032 (2SD, n=24) and 0.512227±0.000036 (2SD, n=42) for Jndi-1 and JMC-Nd solutions respectively, while analysis of 1 ng JMC475 Hf gave 176Hf/177Hf ratios of 0.282163±0.000027 (2SD, n=21). These results are in agreements with their reference values. Potential interfering elements Ce and Sm are found to have insignificant influence on 143Nd/144Nd ratios. Lu and Yb have remarkable effect on 176Hf/177Hf ratios. Improved correction performance can be achieved by using Lu and Yb ratios obtained by analyzing pure Lu and Yb solutions. Five chemically purified rock reference materials are measured with the presented method and the results are consistent with their recommended values. Relative to other approaches, this protocol is rapid and accurate, and can be widely applied in Nd and Hf isotope analysis of samples with trace amounts of Nd and Hf (<10 ng).
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
6.20
自引率
26.50%
发文量
228
审稿时长
1.7 months
期刊介绍: Innovative research on the fundamental theory and application of spectrometric techniques.
期刊最新文献
Back cover Titanomagnetite, a new potential geochronometer for in situ U–Pb dating A simplified instrumental protocol for trace Nd and Hf isotope measurements (<10 ng) by MC-ICP-MS and Apex Omega de-solvating system Simultaneous determination of the oxygen isotope ratio and vola-tile composition of apatite with high lateral resolution via nano-secondary-ion mass spectrometry Development and application of reference and routine analytical methods providing SI-traceable results for the determination of technology-critical elements in PCB from WEEE
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1