纸质微流控哨点传感器可在社区环境中快速进行现场废水监测

IF 7.9 2区 综合性期刊 Q1 CHEMISTRY, MULTIDISCIPLINARY Cell Reports Physical Science Pub Date : 2024-09-19 DOI:10.1016/j.xcrp.2024.102154
Yuwei Pan, Baojun Wang, Jonathan M. Cooper, Zhugen Yang
{"title":"纸质微流控哨点传感器可在社区环境中快速进行现场废水监测","authors":"Yuwei Pan, Baojun Wang, Jonathan M. Cooper, Zhugen Yang","doi":"10.1016/j.xcrp.2024.102154","DOIUrl":null,"url":null,"abstract":"<p>Tracking genomic sequences as microbial biomarkers in wastewater has been used to determine community prevalence of infectious diseases, contributing to public health surveillance programs worldwide. Here, we report upon a low-cost, rapid, and user-friendly paper microfluidic platform for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and influenza detection, using loop-mediated isothermal amplification, with signal read using a mobile phone camera. Sample-to-answer results were collected in less than 1.5 h, providing rapid multiplexed detection of viruses in wastewater, with a detection limit of &lt;20 copies mL<sup>−1</sup>. The device was subsequently used for on-site testing of SARS-CoV-2 in wastewater samples from four quarantine hotels at London Heathrow Airport, showing comparable results to those obtained using polymerase chain reaction. This sensing platform, which enables rapid and localized testing without requiring samples to be sent to centralized laboratories, provides a potentially important public health tool for pandemic preparedness, with a variety of future wastewater surveillance applications in community settings.</p>","PeriodicalId":9703,"journal":{"name":"Cell Reports Physical Science","volume":null,"pages":null},"PeriodicalIF":7.9000,"publicationDate":"2024-09-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Paper microfluidic sentinel sensors enable rapid and on-site wastewater surveillance in community settings\",\"authors\":\"Yuwei Pan, Baojun Wang, Jonathan M. Cooper, Zhugen Yang\",\"doi\":\"10.1016/j.xcrp.2024.102154\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Tracking genomic sequences as microbial biomarkers in wastewater has been used to determine community prevalence of infectious diseases, contributing to public health surveillance programs worldwide. Here, we report upon a low-cost, rapid, and user-friendly paper microfluidic platform for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and influenza detection, using loop-mediated isothermal amplification, with signal read using a mobile phone camera. Sample-to-answer results were collected in less than 1.5 h, providing rapid multiplexed detection of viruses in wastewater, with a detection limit of &lt;20 copies mL<sup>−1</sup>. The device was subsequently used for on-site testing of SARS-CoV-2 in wastewater samples from four quarantine hotels at London Heathrow Airport, showing comparable results to those obtained using polymerase chain reaction. This sensing platform, which enables rapid and localized testing without requiring samples to be sent to centralized laboratories, provides a potentially important public health tool for pandemic preparedness, with a variety of future wastewater surveillance applications in community settings.</p>\",\"PeriodicalId\":9703,\"journal\":{\"name\":\"Cell Reports Physical Science\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":7.9000,\"publicationDate\":\"2024-09-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Cell Reports Physical Science\",\"FirstCategoryId\":\"103\",\"ListUrlMain\":\"https://doi.org/10.1016/j.xcrp.2024.102154\",\"RegionNum\":2,\"RegionCategory\":\"综合性期刊\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cell Reports Physical Science","FirstCategoryId":"103","ListUrlMain":"https://doi.org/10.1016/j.xcrp.2024.102154","RegionNum":2,"RegionCategory":"综合性期刊","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

摘要

跟踪废水中作为微生物生物标志物的基因组序列已被用于确定传染病在社区的流行情况,为全球公共卫生监测计划做出了贡献。在此,我们报告了一种低成本、快速、用户友好的纸质微流控平台,该平台采用环介导等温扩增技术,使用手机摄像头读取信号,用于检测严重急性呼吸系统综合征冠状病毒 2(SARS-CoV-2)和流感。从样品到回答结果的采集时间不到 1.5 小时,可对废水中的病毒进行快速多重检测,检测限为 20 拷贝 mL-1。该设备随后被用于现场检测伦敦希思罗机场四家隔离酒店废水样本中的 SARS-CoV-2 病毒,结果与使用聚合酶链反应获得的结果相当。这种传感平台可进行快速和本地化检测,无需将样本送往集中实验室,为大流行病防备提供了一种潜在的重要公共卫生工具,未来可在社区环境中进行各种废水监测应用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Paper microfluidic sentinel sensors enable rapid and on-site wastewater surveillance in community settings

Tracking genomic sequences as microbial biomarkers in wastewater has been used to determine community prevalence of infectious diseases, contributing to public health surveillance programs worldwide. Here, we report upon a low-cost, rapid, and user-friendly paper microfluidic platform for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and influenza detection, using loop-mediated isothermal amplification, with signal read using a mobile phone camera. Sample-to-answer results were collected in less than 1.5 h, providing rapid multiplexed detection of viruses in wastewater, with a detection limit of <20 copies mL−1. The device was subsequently used for on-site testing of SARS-CoV-2 in wastewater samples from four quarantine hotels at London Heathrow Airport, showing comparable results to those obtained using polymerase chain reaction. This sensing platform, which enables rapid and localized testing without requiring samples to be sent to centralized laboratories, provides a potentially important public health tool for pandemic preparedness, with a variety of future wastewater surveillance applications in community settings.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Cell Reports Physical Science
Cell Reports Physical Science Energy-Energy (all)
CiteScore
11.40
自引率
2.20%
发文量
388
审稿时长
62 days
期刊介绍: Cell Reports Physical Science, a premium open-access journal from Cell Press, features high-quality, cutting-edge research spanning the physical sciences. It serves as an open forum fostering collaboration among physical scientists while championing open science principles. Published works must signify significant advancements in fundamental insight or technological applications within fields such as chemistry, physics, materials science, energy science, engineering, and related interdisciplinary studies. In addition to longer articles, the journal considers impactful short-form reports and short reviews covering recent literature in emerging fields. Continually adapting to the evolving open science landscape, the journal reviews its policies to align with community consensus and best practices.
期刊最新文献
Paper microfluidic sentinel sensors enable rapid and on-site wastewater surveillance in community settings Catalyzing deep decarbonization with federated battery diagnosis and prognosis for better data management in energy storage systems 4.8-V all-solid-state garnet-based lithium-metal batteries with stable interface Deformation of collagen-based tissues investigated using a systematic review and meta-analysis of synchrotron x-ray scattering studies Catalysis for plastic deconstruction and upcycling
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1