{"title":"唾液腺闪烁成像中的参数成像。","authors":"Rogério Anton Faria, Graziella Chagas Jaguar, Eduardo Nóbrega Pereira Lima","doi":"10.1097/MNM.0000000000001901","DOIUrl":null,"url":null,"abstract":"<p><p>Salivary gland scintigraphy (SGS) is an imaging technique to evaluate functional aspects of the salivary glands. First described in 1965, visual analyses of summed images and of time-activity curves generated through regions of interest (ROI) are still the main evaluation tools used in clinical practice. An alternative to ROI-based analysis is the use of parametric images, which are images generated through pixel-by-pixel calculation of parameters from the original frames. In this article, we would like to present some parametric images for SGS studies and how to create and use them. Two images, vascular flow and uptake velocity, were created using the intercept and slope of a linear model of the frames from after the first to fifth minute of acquisition. And two others, excretion fraction and absolute excretion, by subtraction and division methods of the frames before and after sialogogue stimulation. These images allow the visualization of the spatial distribution and heterogeneity of these quantitative parameters, favoring different forms of analysis and helping with image segmentation. After more than a year of using these images in daily routine, our general impression is that they have been very helpful. This article, however, still represents only our early experiences with this technique, and clinical studies are yet needed to better evaluate this method.</p>","PeriodicalId":19708,"journal":{"name":"Nuclear Medicine Communications","volume":" ","pages":"1098-1104"},"PeriodicalIF":1.3000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Parametric imaging in salivary gland scintigraphy.\",\"authors\":\"Rogério Anton Faria, Graziella Chagas Jaguar, Eduardo Nóbrega Pereira Lima\",\"doi\":\"10.1097/MNM.0000000000001901\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Salivary gland scintigraphy (SGS) is an imaging technique to evaluate functional aspects of the salivary glands. First described in 1965, visual analyses of summed images and of time-activity curves generated through regions of interest (ROI) are still the main evaluation tools used in clinical practice. An alternative to ROI-based analysis is the use of parametric images, which are images generated through pixel-by-pixel calculation of parameters from the original frames. In this article, we would like to present some parametric images for SGS studies and how to create and use them. Two images, vascular flow and uptake velocity, were created using the intercept and slope of a linear model of the frames from after the first to fifth minute of acquisition. And two others, excretion fraction and absolute excretion, by subtraction and division methods of the frames before and after sialogogue stimulation. These images allow the visualization of the spatial distribution and heterogeneity of these quantitative parameters, favoring different forms of analysis and helping with image segmentation. After more than a year of using these images in daily routine, our general impression is that they have been very helpful. This article, however, still represents only our early experiences with this technique, and clinical studies are yet needed to better evaluate this method.</p>\",\"PeriodicalId\":19708,\"journal\":{\"name\":\"Nuclear Medicine Communications\",\"volume\":\" \",\"pages\":\"1098-1104\"},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2024-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Nuclear Medicine Communications\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/MNM.0000000000001901\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/9/18 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nuclear Medicine Communications","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/MNM.0000000000001901","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/9/18 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

唾液腺闪烁扫描(SGS)是一种评估唾液腺功能的成像技术。该技术于 1965 年首次被描述,通过感兴趣区(ROI)生成的总和图像和时间活动曲线的视觉分析仍是临床实践中使用的主要评估工具。参数图像是基于原始图像逐像素计算参数生成的图像,是基于 ROI 分析的另一种替代方法。本文将介绍一些用于 SGS 研究的参数图像,以及如何创建和使用这些图像。血管流量和摄取速度这两幅图像是利用从采集第一分钟到第五分钟的帧线性模型的截距和斜率生成的。另外两幅图像,即排泄分数和绝对排泄量,则是通过对sialogogue刺激前后的帧进行减法和除法计算得出的。通过这些图像可以观察到这些定量参数的空间分布和异质性,有利于进行不同形式的分析,并有助于图像分割。经过一年多在日常工作中使用这些图像,我们的总体印象是它们非常有用。不过,这篇文章还只是我们使用这项技术的早期经验,还需要进行临床研究,以更好地评估这种方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Parametric imaging in salivary gland scintigraphy.

Salivary gland scintigraphy (SGS) is an imaging technique to evaluate functional aspects of the salivary glands. First described in 1965, visual analyses of summed images and of time-activity curves generated through regions of interest (ROI) are still the main evaluation tools used in clinical practice. An alternative to ROI-based analysis is the use of parametric images, which are images generated through pixel-by-pixel calculation of parameters from the original frames. In this article, we would like to present some parametric images for SGS studies and how to create and use them. Two images, vascular flow and uptake velocity, were created using the intercept and slope of a linear model of the frames from after the first to fifth minute of acquisition. And two others, excretion fraction and absolute excretion, by subtraction and division methods of the frames before and after sialogogue stimulation. These images allow the visualization of the spatial distribution and heterogeneity of these quantitative parameters, favoring different forms of analysis and helping with image segmentation. After more than a year of using these images in daily routine, our general impression is that they have been very helpful. This article, however, still represents only our early experiences with this technique, and clinical studies are yet needed to better evaluate this method.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.20
自引率
6.70%
发文量
212
审稿时长
3-8 weeks
期刊介绍: Nuclear Medicine Communications, the official journal of the British Nuclear Medicine Society, is a rapid communications journal covering nuclear medicine and molecular imaging with radionuclides, and the basic supporting sciences. As well as clinical research and commentary, manuscripts describing research on preclinical and basic sciences (radiochemistry, radiopharmacy, radiobiology, radiopharmacology, medical physics, computing and engineering, and technical and nursing professions involved in delivering nuclear medicine services) are welcomed, as the journal is intended to be of interest internationally to all members of the many medical and non-medical disciplines involved in nuclear medicine. In addition to papers reporting original studies, frankly written editorials and topical reviews are a regular feature of the journal.
期刊最新文献
Correlation between 18 F-FDG PET/CT metabolic parameters and microvascular invasion before liver transplantation in patients with hepatocellular carcinoma. Evaluation of jaw pathologies of patients with medication-related osteonecrosis of the jaw using a computer program to assess the bone scan index: comparison of standardized uptake values with bone SPECT/CT. Parametric imaging in salivary gland scintigraphy. Predicting invasiveness of ground-glass nodules in lung adenocarcinoma: based on preoperative 18 F-fluorodeoxyglucose PET/computed tomography and high-resolution computed tomography. SeHCAT retention measurements may be compromised by traces of 177 Lu/ 177m Lu more than 90 days after 177 Lu-DOTATATE was administered.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1