[关于常规散光参数分析方法的诊断准确性问题]。

Q3 Medicine Vestnik oftalmologii Pub Date : 2024-01-01 DOI:10.17116/oftalma202414004126
S E Avetisov, A N Evdokimova
{"title":"[关于常规散光参数分析方法的诊断准确性问题]。","authors":"S E Avetisov, A N Evdokimova","doi":"10.17116/oftalma202414004126","DOIUrl":null,"url":null,"abstract":"<p><p>Accurate measurement of astigmatism parameters is the basis for prescribing modern means of optical correction. In recent years, another direction for correcting astigmatism has emerged - implantation of toric intraocular lenses (TIOL).</p><p><strong>Purpose: </strong>This study evaluates the diagnostic accuracy of various methods for measuring the parameters of regular astigmatism.</p><p><strong>Material and methods: </strong>The study included 83 patients (122 eyes) with regular astigmatism exceeding 1.0 D. Three groups were formed depending on the type of astigmatism. Spherical and cylindrical (power and axis) components of refraction were determined using automatic refractometry. The results were refined with subjective tests: power and axis tests with a cross-cylinder. The criterion for diagnostic accuracy was the level of corrected visual acuity. To assess the impact of cylinder position on visual acuity, discrete deviations of the axis of trial astigmatic lenses from the correct position (determined based on subjective tests) were modeled at 5, 10, and 15 degrees in both clockwise and counterclockwise directions.</p><p><strong>Results: </strong>In the overall sample of observations, coincidence of results was found only in one-third of cases, with a tendency for discrepancies in data between the two methods in nearly 70% of cases. Statistical processing revealed significant differences only in the magnitude of the cylinder in the group with against-the-rule astigmatism (<i>p</i><0.0005). An increase in maximum visual acuity corrected based on subjective test data was noted. With a deviation of the cylinder axis from the correct position by 10-15 degrees, regardless of the type of astigmatism, a significant tendency for a decrease in visual acuity was identified. At the same time, with a deviation of the cylinder axis within 5 degrees, a significant decrease in visual acuity was noted only in with-the-rule astigmatism and counterclockwise deviation.</p><p><strong>Conclusion: </strong>To achieve maximum visual acuity in the correction of regular astigmatism, objective method data must be refined with subjective tests. The results of modeling the deviation of the axis of the corrective lens from the proper position can be considered when evaluating the functional outcomes of TIOL implantation.</p>","PeriodicalId":23529,"journal":{"name":"Vestnik oftalmologii","volume":"140 4","pages":"26-32"},"PeriodicalIF":0.0000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[On the issue of diagnostic accuracy of methods for analyzing the parameters of regular astigmatism].\",\"authors\":\"S E Avetisov, A N Evdokimova\",\"doi\":\"10.17116/oftalma202414004126\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Accurate measurement of astigmatism parameters is the basis for prescribing modern means of optical correction. In recent years, another direction for correcting astigmatism has emerged - implantation of toric intraocular lenses (TIOL).</p><p><strong>Purpose: </strong>This study evaluates the diagnostic accuracy of various methods for measuring the parameters of regular astigmatism.</p><p><strong>Material and methods: </strong>The study included 83 patients (122 eyes) with regular astigmatism exceeding 1.0 D. Three groups were formed depending on the type of astigmatism. Spherical and cylindrical (power and axis) components of refraction were determined using automatic refractometry. The results were refined with subjective tests: power and axis tests with a cross-cylinder. The criterion for diagnostic accuracy was the level of corrected visual acuity. To assess the impact of cylinder position on visual acuity, discrete deviations of the axis of trial astigmatic lenses from the correct position (determined based on subjective tests) were modeled at 5, 10, and 15 degrees in both clockwise and counterclockwise directions.</p><p><strong>Results: </strong>In the overall sample of observations, coincidence of results was found only in one-third of cases, with a tendency for discrepancies in data between the two methods in nearly 70% of cases. Statistical processing revealed significant differences only in the magnitude of the cylinder in the group with against-the-rule astigmatism (<i>p</i><0.0005). An increase in maximum visual acuity corrected based on subjective test data was noted. With a deviation of the cylinder axis from the correct position by 10-15 degrees, regardless of the type of astigmatism, a significant tendency for a decrease in visual acuity was identified. At the same time, with a deviation of the cylinder axis within 5 degrees, a significant decrease in visual acuity was noted only in with-the-rule astigmatism and counterclockwise deviation.</p><p><strong>Conclusion: </strong>To achieve maximum visual acuity in the correction of regular astigmatism, objective method data must be refined with subjective tests. The results of modeling the deviation of the axis of the corrective lens from the proper position can be considered when evaluating the functional outcomes of TIOL implantation.</p>\",\"PeriodicalId\":23529,\"journal\":{\"name\":\"Vestnik oftalmologii\",\"volume\":\"140 4\",\"pages\":\"26-32\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Vestnik oftalmologii\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.17116/oftalma202414004126\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Vestnik oftalmologii","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17116/oftalma202414004126","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

准确测量散光参数是制定现代光学矫正方法的基础。近年来,出现了矫正散光的另一个方向--植入散光眼内透镜(TIOL)。目的:本研究评估了测量规则散光参数的各种方法的诊断准确性:根据散光类型分为三组。使用自动屈光仪测定屈光的球面和柱面(功率和轴)成分。通过主观测试对结果进行完善:使用交叉圆筒进行功率和轴测试。诊断准确性的标准是矫正视力水平。为了评估柱镜位置对视力的影响,对试验散光镜片的轴线与正确位置(根据主观测试确定)的离散偏差进行了建模,分别为顺时针和逆时针方向 5 度、10 度和 15 度:在所有观察样本中,只有三分之一的结果是一致的,近 70% 的结果显示两种方法的数据存在差异。统计处理显示,只有逆规则散光组的圆柱度有明显差异(p):为了在矫正规则散光时达到最大视力,客观方法的数据必须与主观测试相结合。在评估 TIOL 植入术的功能结果时,可以考虑矫正透镜轴线偏离正确位置的建模结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
[On the issue of diagnostic accuracy of methods for analyzing the parameters of regular astigmatism].

Accurate measurement of astigmatism parameters is the basis for prescribing modern means of optical correction. In recent years, another direction for correcting astigmatism has emerged - implantation of toric intraocular lenses (TIOL).

Purpose: This study evaluates the diagnostic accuracy of various methods for measuring the parameters of regular astigmatism.

Material and methods: The study included 83 patients (122 eyes) with regular astigmatism exceeding 1.0 D. Three groups were formed depending on the type of astigmatism. Spherical and cylindrical (power and axis) components of refraction were determined using automatic refractometry. The results were refined with subjective tests: power and axis tests with a cross-cylinder. The criterion for diagnostic accuracy was the level of corrected visual acuity. To assess the impact of cylinder position on visual acuity, discrete deviations of the axis of trial astigmatic lenses from the correct position (determined based on subjective tests) were modeled at 5, 10, and 15 degrees in both clockwise and counterclockwise directions.

Results: In the overall sample of observations, coincidence of results was found only in one-third of cases, with a tendency for discrepancies in data between the two methods in nearly 70% of cases. Statistical processing revealed significant differences only in the magnitude of the cylinder in the group with against-the-rule astigmatism (p<0.0005). An increase in maximum visual acuity corrected based on subjective test data was noted. With a deviation of the cylinder axis from the correct position by 10-15 degrees, regardless of the type of astigmatism, a significant tendency for a decrease in visual acuity was identified. At the same time, with a deviation of the cylinder axis within 5 degrees, a significant decrease in visual acuity was noted only in with-the-rule astigmatism and counterclockwise deviation.

Conclusion: To achieve maximum visual acuity in the correction of regular astigmatism, objective method data must be refined with subjective tests. The results of modeling the deviation of the axis of the corrective lens from the proper position can be considered when evaluating the functional outcomes of TIOL implantation.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Vestnik oftalmologii
Vestnik oftalmologii Medicine-Ophthalmology
CiteScore
0.80
自引率
0.00%
发文量
129
期刊介绍: The journal publishes materials on the diagnosis and treatment of eye diseases, hygiene of vision, prevention of ophthalmic affections, history of Russian ophthalmology, organization of ophthalmological aid to the population, as well as the problems of special equipment. Original scientific articles and surveys on urgent problems of theory and practice of Russian and foreign ophthalmology are published. The journal contains book reviews on ophthalmology, information on the activities of ophthalmologists" scientific societies, chronicle of congresses and conferences.The journal is intended for ophthalmologists and scientific workers dealing with clinical problems of diseases of the eye and physiology of vision.
期刊最新文献
[Structural and functional features of the eye in Marfan syndrome. Report 2. Changes in the anatomical complex of the lens]. [Subfamily of betaherpesviruses as a cause of epithelial and stromal keratitis]. [Terson syndrome and acute myeloid leukemia (case report)]. [The association between myopia and glaucoma]. [The effect of pleoptic treatment on the stability of visual fixation in children and adolescents with amblyopia of various degrees].
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1