金属髋关节置换术后的金属离子水平:一项针对中国患者的单中心纵向研究。

Yanlin Wan, Jia You, Wenxue Jiang, Pengfei Wang, Qun Xia
{"title":"金属髋关节置换术后的金属离子水平:一项针对中国患者的单中心纵向研究。","authors":"Yanlin Wan, Jia You, Wenxue Jiang, Pengfei Wang, Qun Xia","doi":"10.5152/j.aott.2024.23096","DOIUrl":null,"url":null,"abstract":"<p><p>This study aimed to investigate the long-term serum metal ion levels of patients who received metal-on-metal hip resurfacing arthroplasty (MoM HRA). We conducted a retrospective study of 99 patients (110 hips) from March 2006 to May 2017 who underwent MoM HRA. The Harris Hip Score (HHS) and the University of California at Los Angeles (UCLA) activity score were measured, and the patients underwent clinical and radiological management. Serum levels of cobalt (Co), chromium (Cr), and molybdenum (Mo) were measured using inductively coupled plasma mass spectrometry (ICPMS) at 1, 6, and 12 months, and each year follow-up after prosthesis implantation. Patients were followed up from 1 to 156 months, with a mean of 98 months. No complications occurred. Metal ion analysis revealed significantly elevated levels compared to preoperative levels. The metal ions levels increased and reached a peak after surgery, and then the levels began to decline gradually. Approximately 84-108 months after surgery, the metal ion levels increased again to approximately peak levels. Then, up to 156 months after surgery, the metal ions levels will drop approximately to preoperative levels. The serum levels of Cr in women were higher than those in men, with the difference being statistically significant. Patients with a body mass index (BMI) of ≥24.9 kg/m2 Co levels were significantly higher than those of normal-weight patients. The serum levels of metal ions showed no significant differences between the prostheses. The use of the MoM HRA was clinically effective, and the Co, Cr, and Mo levels increased significantly after HRA; however, upon long-term follow-up, serum metal ion levels tended to decrease to preoperative levels. Longer follow-up periods and larger study samples are needed to establish the long-term outcome of patients undergoing HRA with MoM bearings. Level IV, Therapeutic Study.</p>","PeriodicalId":93854,"journal":{"name":"Acta orthopaedica et traumatologica turcica","volume":"58 4","pages":"196-202"},"PeriodicalIF":0.0000,"publicationDate":"2024-07-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11448754/pdf/","citationCount":"0","resultStr":"{\"title\":\"Metal ion levels after metal-on-metal hip resurfacing: A single-center longitudinal study of Chinese patients.\",\"authors\":\"Yanlin Wan, Jia You, Wenxue Jiang, Pengfei Wang, Qun Xia\",\"doi\":\"10.5152/j.aott.2024.23096\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>This study aimed to investigate the long-term serum metal ion levels of patients who received metal-on-metal hip resurfacing arthroplasty (MoM HRA). We conducted a retrospective study of 99 patients (110 hips) from March 2006 to May 2017 who underwent MoM HRA. The Harris Hip Score (HHS) and the University of California at Los Angeles (UCLA) activity score were measured, and the patients underwent clinical and radiological management. Serum levels of cobalt (Co), chromium (Cr), and molybdenum (Mo) were measured using inductively coupled plasma mass spectrometry (ICPMS) at 1, 6, and 12 months, and each year follow-up after prosthesis implantation. Patients were followed up from 1 to 156 months, with a mean of 98 months. No complications occurred. Metal ion analysis revealed significantly elevated levels compared to preoperative levels. The metal ions levels increased and reached a peak after surgery, and then the levels began to decline gradually. Approximately 84-108 months after surgery, the metal ion levels increased again to approximately peak levels. Then, up to 156 months after surgery, the metal ions levels will drop approximately to preoperative levels. The serum levels of Cr in women were higher than those in men, with the difference being statistically significant. Patients with a body mass index (BMI) of ≥24.9 kg/m2 Co levels were significantly higher than those of normal-weight patients. The serum levels of metal ions showed no significant differences between the prostheses. The use of the MoM HRA was clinically effective, and the Co, Cr, and Mo levels increased significantly after HRA; however, upon long-term follow-up, serum metal ion levels tended to decrease to preoperative levels. Longer follow-up periods and larger study samples are needed to establish the long-term outcome of patients undergoing HRA with MoM bearings. Level IV, Therapeutic Study.</p>\",\"PeriodicalId\":93854,\"journal\":{\"name\":\"Acta orthopaedica et traumatologica turcica\",\"volume\":\"58 4\",\"pages\":\"196-202\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-07-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11448754/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta orthopaedica et traumatologica turcica\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5152/j.aott.2024.23096\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta orthopaedica et traumatologica turcica","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5152/j.aott.2024.23096","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本研究旨在调查接受金属髋关节置换术(MoM HRA)患者的长期血清金属离子水平。我们对 2006 年 3 月至 2017 年 5 月期间接受金属髋关节置换术的 99 例患者(110 个髋关节)进行了回顾性研究。我们测量了哈里斯髋关节评分(HHS)和加州大学洛杉矶分校(UCLA)活动度评分,并对患者进行了临床和放射学管理。在假体植入后的 1 个月、6 个月、12 个月和每年的随访期间,使用电感耦合等离子体质谱法(ICPMS)测量血清中钴(Co)、铬(Cr)和钼(Mo)的含量。患者的随访时间从 1 个月到 156 个月不等,平均为 98 个月。无并发症发生。金属离子分析显示,与术前水平相比,金属离子水平明显升高。金属离子水平在手术后上升并达到峰值,然后开始逐渐下降。术后约 84-108 个月,金属离子水平再次升高至接近峰值水平。然后,在术后 156 个月内,金属离子水平将大致降至术前水平。女性血清中的铬含量高于男性,差异具有统计学意义。体重指数(BMI)≥24.9 kg/m2的患者的Co水平明显高于正常体重的患者。不同假体的血清金属离子水平无明显差异。使用 MoM HRA 在临床上是有效的,HRA 后 Co、Cr 和 Mo 的水平明显升高;但在长期随访中,血清金属离子水平趋于降至术前水平。需要更长的随访时间和更大的研究样本来确定使用 MoM 轴承进行 HRA 患者的长期疗效。四级,治疗性研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Metal ion levels after metal-on-metal hip resurfacing: A single-center longitudinal study of Chinese patients.

This study aimed to investigate the long-term serum metal ion levels of patients who received metal-on-metal hip resurfacing arthroplasty (MoM HRA). We conducted a retrospective study of 99 patients (110 hips) from March 2006 to May 2017 who underwent MoM HRA. The Harris Hip Score (HHS) and the University of California at Los Angeles (UCLA) activity score were measured, and the patients underwent clinical and radiological management. Serum levels of cobalt (Co), chromium (Cr), and molybdenum (Mo) were measured using inductively coupled plasma mass spectrometry (ICPMS) at 1, 6, and 12 months, and each year follow-up after prosthesis implantation. Patients were followed up from 1 to 156 months, with a mean of 98 months. No complications occurred. Metal ion analysis revealed significantly elevated levels compared to preoperative levels. The metal ions levels increased and reached a peak after surgery, and then the levels began to decline gradually. Approximately 84-108 months after surgery, the metal ion levels increased again to approximately peak levels. Then, up to 156 months after surgery, the metal ions levels will drop approximately to preoperative levels. The serum levels of Cr in women were higher than those in men, with the difference being statistically significant. Patients with a body mass index (BMI) of ≥24.9 kg/m2 Co levels were significantly higher than those of normal-weight patients. The serum levels of metal ions showed no significant differences between the prostheses. The use of the MoM HRA was clinically effective, and the Co, Cr, and Mo levels increased significantly after HRA; however, upon long-term follow-up, serum metal ion levels tended to decrease to preoperative levels. Longer follow-up periods and larger study samples are needed to establish the long-term outcome of patients undergoing HRA with MoM bearings. Level IV, Therapeutic Study.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Assessment of spinopelvic relationship among Turkish orthopedic surgeons in total joint replacement: a survey. Asymptomatic iatrogenic bilateral occlusion of vertebral artery after atlantoaxial fusion: a case report. Bibliometric analysis of the Acta Orthopaedica et Traumatologica Turcica from 2013 to 2022. Comparison of autologous matrix-induced chondrogenesis and mosaicplasty in the treatment of osteochondral defects of the talus. Comparison of mechanical stability of modified pedicle screw fixator and unilateral lumbopelvic fixation for treating sacroiliac joint disruption: A finite element analysis study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1