使用牵引器安装的摄像头和平视显示器进行俯卧位转侧椎体间融合术:示例。

Suraj Sulhan, Jonathan N Sellin
{"title":"使用牵引器安装的摄像头和平视显示器进行俯卧位转侧椎体间融合术:示例。","authors":"Suraj Sulhan, Jonathan N Sellin","doi":"10.3171/CASE24318","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The prone transpsoas (PTP) technique involves the performance of a lateral lumbar interbody fusion with the patient prone. One challenge encountered in the early experience with the PTP technique is that with the patient in the prone position rather than the lateral decubitus position, the surgeon is often forced to raise the bed significantly and perform the interbody work in a hunched and seated position with their neck extended and shoulders abducted. The authors report on the use of a sterile retractor-mounted camera during PTP that allows for the surgery to be performed with surgical anatomy visualized on a heads-up display.</p><p><strong>Observations: </strong>The PTP procedure is performed without significant modification from standard practice. After the self-retaining retractor is inserted, a sterile retractor-mounted camera can be introduced down one of the blades of the self-retaining retractor, preferably the dorsally situated blade to avoid camera line-of-sight issues with dependent irrigation or bleeding. The surgical field can now be visualized on a high-definition monitor, allowing the surgeon to stand at the patient's side instead of sitting.</p><p><strong>Lessons: </strong>A sterile retractor-mounted camera with a heads-up display is a novel way to address ergonomic challenges as well as improve educational opportunities in the operating room. https://thejns.org/doi/10.3171/CASE24318.</p>","PeriodicalId":94098,"journal":{"name":"Journal of neurosurgery. Case lessons","volume":"8 14","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-09-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11445863/pdf/","citationCount":"0","resultStr":"{\"title\":\"Prone transpsoas lateral interbody fusion with retractor-mounted camera and heads-up display: illustrative case.\",\"authors\":\"Suraj Sulhan, Jonathan N Sellin\",\"doi\":\"10.3171/CASE24318\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>The prone transpsoas (PTP) technique involves the performance of a lateral lumbar interbody fusion with the patient prone. One challenge encountered in the early experience with the PTP technique is that with the patient in the prone position rather than the lateral decubitus position, the surgeon is often forced to raise the bed significantly and perform the interbody work in a hunched and seated position with their neck extended and shoulders abducted. The authors report on the use of a sterile retractor-mounted camera during PTP that allows for the surgery to be performed with surgical anatomy visualized on a heads-up display.</p><p><strong>Observations: </strong>The PTP procedure is performed without significant modification from standard practice. After the self-retaining retractor is inserted, a sterile retractor-mounted camera can be introduced down one of the blades of the self-retaining retractor, preferably the dorsally situated blade to avoid camera line-of-sight issues with dependent irrigation or bleeding. The surgical field can now be visualized on a high-definition monitor, allowing the surgeon to stand at the patient's side instead of sitting.</p><p><strong>Lessons: </strong>A sterile retractor-mounted camera with a heads-up display is a novel way to address ergonomic challenges as well as improve educational opportunities in the operating room. https://thejns.org/doi/10.3171/CASE24318.</p>\",\"PeriodicalId\":94098,\"journal\":{\"name\":\"Journal of neurosurgery. Case lessons\",\"volume\":\"8 14\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-09-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11445863/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of neurosurgery. Case lessons\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3171/CASE24318\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of neurosurgery. Case lessons","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3171/CASE24318","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

背景:俯卧位跨腰椎(PTP)技术是指在患者俯卧位的情况下进行侧腰椎椎间融合术。在使用 PTP 技术的早期经验中遇到的一个挑战是,当患者处于俯卧位而不是侧卧位时,外科医生往往被迫大幅抬高床位,并以驼背和坐姿进行椎体间融合术,此时患者颈部伸直,肩部外展。作者报告了在 PTP 过程中使用安装在无菌牵引器上的摄像头的情况,这种摄像头可以在平视显示器上显示手术解剖结构的情况下进行手术:观察结果:PTP 手术的实施与标准做法相比没有重大改变。插入自留置牵开器后,可将安装在牵开器上的无菌摄像头从自留置牵开器的一个刀片(最好是背侧刀片)向下导入,以避免摄像头视线受到依赖性灌洗或出血的影响。现在,手术区域可以在高清显示器上看到,外科医生可以站在病人身边,而不是坐着:https://thejns.org/doi/10.3171/CASE24318。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Prone transpsoas lateral interbody fusion with retractor-mounted camera and heads-up display: illustrative case.

Background: The prone transpsoas (PTP) technique involves the performance of a lateral lumbar interbody fusion with the patient prone. One challenge encountered in the early experience with the PTP technique is that with the patient in the prone position rather than the lateral decubitus position, the surgeon is often forced to raise the bed significantly and perform the interbody work in a hunched and seated position with their neck extended and shoulders abducted. The authors report on the use of a sterile retractor-mounted camera during PTP that allows for the surgery to be performed with surgical anatomy visualized on a heads-up display.

Observations: The PTP procedure is performed without significant modification from standard practice. After the self-retaining retractor is inserted, a sterile retractor-mounted camera can be introduced down one of the blades of the self-retaining retractor, preferably the dorsally situated blade to avoid camera line-of-sight issues with dependent irrigation or bleeding. The surgical field can now be visualized on a high-definition monitor, allowing the surgeon to stand at the patient's side instead of sitting.

Lessons: A sterile retractor-mounted camera with a heads-up display is a novel way to address ergonomic challenges as well as improve educational opportunities in the operating room. https://thejns.org/doi/10.3171/CASE24318.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
0.40
自引率
0.00%
发文量
0
期刊最新文献
Convexity dural hemangioma: illustrative case. Detection of face motor activation in the precentral gyrus with functional thermography following inconclusive direct electrical stimulation mapping: illustrative case. Endovascular removal of a symptomatic intracranial foreign body via contact aspiration: illustrative case. Failed ulnar nerve surgery due to persistent unrecognized snapping triceps from cubitus varus due to a distal humeral malunion in an adult: illustrative case. Middle fossa approach for a petrous apex bony spur causing trigeminal neuralgia: illustrative case.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1