不同光学区直径对使用飞秒激光角膜松弛切口矫正角膜散光的影响:8毫米与9毫米

IF 1.7 4区 医学 Q3 OPHTHALMOLOGY Current Eye Research Pub Date : 2024-10-04 DOI:10.1080/02713683.2024.2408395
Zhangliang Li, Yiyi Wang, Ziqi Meng, Yalan Wang, Xicong Lou, Zehui Zhu, Jing Jin, Yun-E Zhao
{"title":"不同光学区直径对使用飞秒激光角膜松弛切口矫正角膜散光的影响:8毫米与9毫米","authors":"Zhangliang Li, Yiyi Wang, Ziqi Meng, Yalan Wang, Xicong Lou, Zehui Zhu, Jing Jin, Yun-E Zhao","doi":"10.1080/02713683.2024.2408395","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To compare the impact of 8 mm versus 9 mm optical zone (OZ) diameters on corneal astigmatism correction and to evaluate the impact of incision depth percentage after femtosecond laser corneal relaxing incisions (CRIs) combined with cataract surgery.</p><p><strong>Methods: </strong>Thirty-nine eyes from 39 patients were enrolled and randomly assigned to two groups based on the OZ diameter: 8 mm and 9 mm. Corneal astigmatism and CRI depth were measured using Pentacam and anterior segment optical coherence tomography. Vector analysis was performed using Alpins method.</p><p><strong>Results: </strong>In the 8 mm group, postoperative corneal astigmatism was reduced by 0.77 ± 0.61 diopters (D), significantly greater than the reduction of 0.42 ± 0.40 D in the 9 mm group (<i>p</i> < 0.05). The 8 mm group exhibited greater surgically induced astigmatism (SIA), net corneal changes, and a smaller angle of error (AE) (<i>p</i> < 0.05). At 3 months postsurgery, the correction index (CI) values were 0.84 ± 0.39 for the 8 mm group, exceeding the 0.52 ± 0.32 observed in the 9 mm group (<i>p</i> < 0.05). The mean incision depth percentage was significantly higher in the 9 mm group (79.30 ± 10.76%) compared to the 8 mm group (72.58 ± 8.73%) (<i>p</i> < 0.05). In the 8 mm group, CI values closer to 1.00 were associated with lower percentages of incision depth.</p><p><strong>Conclusions: </strong>CRIs with an 8 mm OZ diameter demonstrated superior efficacy in correcting corneal astigmatism with shallower incision depths compared to those with a 9 mm diameter.</p>","PeriodicalId":10782,"journal":{"name":"Current Eye Research","volume":" ","pages":"1-7"},"PeriodicalIF":1.7000,"publicationDate":"2024-10-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The Impact of Different Optical Zone Diameter on Corneal Astigmatism Correction Using Femtosecond Laser Corneal Relaxing Incisions: 8 mm vs 9 mm.\",\"authors\":\"Zhangliang Li, Yiyi Wang, Ziqi Meng, Yalan Wang, Xicong Lou, Zehui Zhu, Jing Jin, Yun-E Zhao\",\"doi\":\"10.1080/02713683.2024.2408395\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To compare the impact of 8 mm versus 9 mm optical zone (OZ) diameters on corneal astigmatism correction and to evaluate the impact of incision depth percentage after femtosecond laser corneal relaxing incisions (CRIs) combined with cataract surgery.</p><p><strong>Methods: </strong>Thirty-nine eyes from 39 patients were enrolled and randomly assigned to two groups based on the OZ diameter: 8 mm and 9 mm. Corneal astigmatism and CRI depth were measured using Pentacam and anterior segment optical coherence tomography. Vector analysis was performed using Alpins method.</p><p><strong>Results: </strong>In the 8 mm group, postoperative corneal astigmatism was reduced by 0.77 ± 0.61 diopters (D), significantly greater than the reduction of 0.42 ± 0.40 D in the 9 mm group (<i>p</i> < 0.05). The 8 mm group exhibited greater surgically induced astigmatism (SIA), net corneal changes, and a smaller angle of error (AE) (<i>p</i> < 0.05). At 3 months postsurgery, the correction index (CI) values were 0.84 ± 0.39 for the 8 mm group, exceeding the 0.52 ± 0.32 observed in the 9 mm group (<i>p</i> < 0.05). The mean incision depth percentage was significantly higher in the 9 mm group (79.30 ± 10.76%) compared to the 8 mm group (72.58 ± 8.73%) (<i>p</i> < 0.05). In the 8 mm group, CI values closer to 1.00 were associated with lower percentages of incision depth.</p><p><strong>Conclusions: </strong>CRIs with an 8 mm OZ diameter demonstrated superior efficacy in correcting corneal astigmatism with shallower incision depths compared to those with a 9 mm diameter.</p>\",\"PeriodicalId\":10782,\"journal\":{\"name\":\"Current Eye Research\",\"volume\":\" \",\"pages\":\"1-7\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2024-10-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Current Eye Research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1080/02713683.2024.2408395\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Current Eye Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/02713683.2024.2408395","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:比较 8 毫米和 9 毫米光学区(OZ)直径对角膜散光矫正的影响,并评估飞秒激光角膜松弛切口(CRI)联合白内障手术后切口深度百分比的影响:39名患者的39只眼睛被纳入研究,并根据OZ直径随机分为两组:8毫米组和9毫米组。使用 Pentacam 和前段光学相干断层扫描测量角膜散光和 CRI 深度。结果:结果:8 毫米组的术后角膜散光减少了 0.77 ± 0.61 个屈光度(D),明显高于 9 毫米组减少的 0.42 ± 0.40 个屈光度(p p p p 结论):与直径为 9 mm 的 CRI 相比,直径为 8 mm OZ 的 CRI 在矫正角膜散光方面效果更佳,切口深度更浅。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The Impact of Different Optical Zone Diameter on Corneal Astigmatism Correction Using Femtosecond Laser Corneal Relaxing Incisions: 8 mm vs 9 mm.

Purpose: To compare the impact of 8 mm versus 9 mm optical zone (OZ) diameters on corneal astigmatism correction and to evaluate the impact of incision depth percentage after femtosecond laser corneal relaxing incisions (CRIs) combined with cataract surgery.

Methods: Thirty-nine eyes from 39 patients were enrolled and randomly assigned to two groups based on the OZ diameter: 8 mm and 9 mm. Corneal astigmatism and CRI depth were measured using Pentacam and anterior segment optical coherence tomography. Vector analysis was performed using Alpins method.

Results: In the 8 mm group, postoperative corneal astigmatism was reduced by 0.77 ± 0.61 diopters (D), significantly greater than the reduction of 0.42 ± 0.40 D in the 9 mm group (p < 0.05). The 8 mm group exhibited greater surgically induced astigmatism (SIA), net corneal changes, and a smaller angle of error (AE) (p < 0.05). At 3 months postsurgery, the correction index (CI) values were 0.84 ± 0.39 for the 8 mm group, exceeding the 0.52 ± 0.32 observed in the 9 mm group (p < 0.05). The mean incision depth percentage was significantly higher in the 9 mm group (79.30 ± 10.76%) compared to the 8 mm group (72.58 ± 8.73%) (p < 0.05). In the 8 mm group, CI values closer to 1.00 were associated with lower percentages of incision depth.

Conclusions: CRIs with an 8 mm OZ diameter demonstrated superior efficacy in correcting corneal astigmatism with shallower incision depths compared to those with a 9 mm diameter.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Current Eye Research
Current Eye Research 医学-眼科学
CiteScore
4.60
自引率
0.00%
发文量
163
审稿时长
12 months
期刊介绍: The principal aim of Current Eye Research is to provide rapid publication of full papers, short communications and mini-reviews, all high quality. Current Eye Research publishes articles encompassing all the areas of eye research. Subject areas include the following: clinical research, anatomy, physiology, biophysics, biochemistry, pharmacology, developmental biology, microbiology and immunology.
期刊最新文献
Relationship of Angle Kappa with Ocular Parameters using Swept-Source Ocular Coherence Tomography in Cataract Surgery Patients. Selective Gamma-Secretase Inhibition by CHF5074 Attenuates Inflammation and Neovascularization in a Murine Model of Choroidal Neovascularization. Expression of PAX6 and Keratocyte-Characteristic Markers in Human Limbal Stromal Cells of Congenital Aniridia and Healthy Subjects, In Vitro. Brolucizumab and Platelet Activation and Reactivity. Correction.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1