{"title":"放射性核素骨 SPECT/CT 成像定量分析在椎体压缩性骨折中的价值:一项回顾性研究。","authors":"Yuhua Wang, Feifei Qiao, Na Li, Ye Liu, Yahong Long, Kang Xu, Jiantao Wang, Wanchun Zhang","doi":"10.1186/s12880-024-01452-9","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Most patients with osteoporosis experience vertebral compression fracture (VCF), which significantly reduces their quality of life. These patients are at a high risk of secondary VCF regardless of treatment. Thus, accurate diagnosis of VCF is important for treating and preventing new fractures. We aimed to investigate the diagnostic and predictive value of quantitative bone imaging techniques for fresh VCF.</p><p><strong>Methods: </strong>From November 2021 to March 2023, 34 patients with VCF were enrolled in this study, all of whom underwent routine <sup>99m</sup>Tc-MDP whole-body bone planar scan and local SPECT/CT imaging. The maximum standard uptake value (SUVmax) of 57 fresh VCF, 57 normal adjacent vertebrae, and 19 old VCF were measured. Based on the site of the fracture, fresh VCFs were regrouped into the intervertebral-type group and the margin-type group. Meanwhile, 52 patients who had no bone metastasis or VCFs in their bone scan were assigned to the control group. The SUVmax of 110 normal vertebral bodies and 10 old VCFs in the control group were measured.</p><p><strong>Results: </strong>The median SUVmax of fresh VCF was 19.80, which was significantly higher than the SUVmax of other groups. The receiver operator characteristic (ROC) curve showed that the cut-off value of SUVmax was 9.925 for diagnosing fresh VCF. The SUVmax in the intervertebral-type group was significantly higher than that in the margin-type group (P = 0.04). The SUVmax of normal vertebrae was higher among patients than among the control group (P<0.01), but the CT HU value showed no significant difference.</p><p><strong>Conclusion: </strong>The quantitative technique of bone SPECT/CT has a significant value in diagnosing fresh VCF. It can also determine the severity of fractures. In addition, whether the SUVs of the vertebrae adjacent to the fractured vertebra can predict re-fracture deserves further studies.</p>","PeriodicalId":9020,"journal":{"name":"BMC Medical Imaging","volume":"24 1","pages":"270"},"PeriodicalIF":2.9000,"publicationDate":"2024-10-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11459896/pdf/","citationCount":"0","resultStr":"{\"title\":\"The value of quantitative analysis of radionuclide bone SPECT/CT imaging in vertebral compression fracture: a retrospective study.\",\"authors\":\"Yuhua Wang, Feifei Qiao, Na Li, Ye Liu, Yahong Long, Kang Xu, Jiantao Wang, Wanchun Zhang\",\"doi\":\"10.1186/s12880-024-01452-9\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Most patients with osteoporosis experience vertebral compression fracture (VCF), which significantly reduces their quality of life. These patients are at a high risk of secondary VCF regardless of treatment. Thus, accurate diagnosis of VCF is important for treating and preventing new fractures. We aimed to investigate the diagnostic and predictive value of quantitative bone imaging techniques for fresh VCF.</p><p><strong>Methods: </strong>From November 2021 to March 2023, 34 patients with VCF were enrolled in this study, all of whom underwent routine <sup>99m</sup>Tc-MDP whole-body bone planar scan and local SPECT/CT imaging. The maximum standard uptake value (SUVmax) of 57 fresh VCF, 57 normal adjacent vertebrae, and 19 old VCF were measured. Based on the site of the fracture, fresh VCFs were regrouped into the intervertebral-type group and the margin-type group. Meanwhile, 52 patients who had no bone metastasis or VCFs in their bone scan were assigned to the control group. The SUVmax of 110 normal vertebral bodies and 10 old VCFs in the control group were measured.</p><p><strong>Results: </strong>The median SUVmax of fresh VCF was 19.80, which was significantly higher than the SUVmax of other groups. The receiver operator characteristic (ROC) curve showed that the cut-off value of SUVmax was 9.925 for diagnosing fresh VCF. The SUVmax in the intervertebral-type group was significantly higher than that in the margin-type group (P = 0.04). The SUVmax of normal vertebrae was higher among patients than among the control group (P<0.01), but the CT HU value showed no significant difference.</p><p><strong>Conclusion: </strong>The quantitative technique of bone SPECT/CT has a significant value in diagnosing fresh VCF. It can also determine the severity of fractures. In addition, whether the SUVs of the vertebrae adjacent to the fractured vertebra can predict re-fracture deserves further studies.</p>\",\"PeriodicalId\":9020,\"journal\":{\"name\":\"BMC Medical Imaging\",\"volume\":\"24 1\",\"pages\":\"270\"},\"PeriodicalIF\":2.9000,\"publicationDate\":\"2024-10-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11459896/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"BMC Medical Imaging\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1186/s12880-024-01452-9\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC Medical Imaging","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s12880-024-01452-9","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
The value of quantitative analysis of radionuclide bone SPECT/CT imaging in vertebral compression fracture: a retrospective study.
Background: Most patients with osteoporosis experience vertebral compression fracture (VCF), which significantly reduces their quality of life. These patients are at a high risk of secondary VCF regardless of treatment. Thus, accurate diagnosis of VCF is important for treating and preventing new fractures. We aimed to investigate the diagnostic and predictive value of quantitative bone imaging techniques for fresh VCF.
Methods: From November 2021 to March 2023, 34 patients with VCF were enrolled in this study, all of whom underwent routine 99mTc-MDP whole-body bone planar scan and local SPECT/CT imaging. The maximum standard uptake value (SUVmax) of 57 fresh VCF, 57 normal adjacent vertebrae, and 19 old VCF were measured. Based on the site of the fracture, fresh VCFs were regrouped into the intervertebral-type group and the margin-type group. Meanwhile, 52 patients who had no bone metastasis or VCFs in their bone scan were assigned to the control group. The SUVmax of 110 normal vertebral bodies and 10 old VCFs in the control group were measured.
Results: The median SUVmax of fresh VCF was 19.80, which was significantly higher than the SUVmax of other groups. The receiver operator characteristic (ROC) curve showed that the cut-off value of SUVmax was 9.925 for diagnosing fresh VCF. The SUVmax in the intervertebral-type group was significantly higher than that in the margin-type group (P = 0.04). The SUVmax of normal vertebrae was higher among patients than among the control group (P<0.01), but the CT HU value showed no significant difference.
Conclusion: The quantitative technique of bone SPECT/CT has a significant value in diagnosing fresh VCF. It can also determine the severity of fractures. In addition, whether the SUVs of the vertebrae adjacent to the fractured vertebra can predict re-fracture deserves further studies.
期刊介绍:
BMC Medical Imaging is an open access journal publishing original peer-reviewed research articles in the development, evaluation, and use of imaging techniques and image processing tools to diagnose and manage disease.