微创方法处理并发中心静脉导管插入的肱动脉主干插管:病例报告。

IF 2 Q2 EMERGENCY MEDICINE International Journal of Emergency Medicine Pub Date : 2024-10-08 DOI:10.1186/s12245-024-00744-9
Haihui Deng, Bin Chen, Deti Peng, Fuwen Pang
{"title":"微创方法处理并发中心静脉导管插入的肱动脉主干插管:病例报告。","authors":"Haihui Deng, Bin Chen, Deti Peng, Fuwen Pang","doi":"10.1186/s12245-024-00744-9","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Central venous catheterization, crucial for device insertion, monitoring, medication, and fluid resuscitation, commonly uses the subclavian, internal jugular, and femoral veins. Despite its general safety, complications like arterial puncture can be life-threatening, requiring rapid diagnosis and treatment.</p><p><strong>Case presentation: </strong>A 74-year-old woman in the recovery phase of cerebral infarction underwent right subclavian vein catheterization. The catheter was mistakenly placed in the brachiocephalic trunk, with its tip in the ascending aorta, as confirmed by computed tomography (CT) and digital subtraction angiography (DSA). With the high surgical risk and the complexity of endovascular treatment, catheter replacement was chosen. One month after the initial placement, the catheter was replaced with a smaller one, and another month later, it was retracted without complications. Follow-up CT and DSA revealed no leakage, with the patient's vitals remaining stable. A three-month post-discharge phone follow-up confirmed the patient's continued stability.</p><p><strong>Conclusion: </strong>This case demonstrates the effective use of a catheter replacement technique as a minimally invasive repair method when other options are impractical. Ultrasound guidance is also recommended to improve the procedure's accuracy and safety.</p>","PeriodicalId":13967,"journal":{"name":"International Journal of Emergency Medicine","volume":"17 1","pages":"145"},"PeriodicalIF":2.0000,"publicationDate":"2024-10-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11460035/pdf/","citationCount":"0","resultStr":"{\"title\":\"Minimally invasive approach to managing brachiocephalic trunk cannulation complicating central venous catheterization: a case report.\",\"authors\":\"Haihui Deng, Bin Chen, Deti Peng, Fuwen Pang\",\"doi\":\"10.1186/s12245-024-00744-9\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Central venous catheterization, crucial for device insertion, monitoring, medication, and fluid resuscitation, commonly uses the subclavian, internal jugular, and femoral veins. Despite its general safety, complications like arterial puncture can be life-threatening, requiring rapid diagnosis and treatment.</p><p><strong>Case presentation: </strong>A 74-year-old woman in the recovery phase of cerebral infarction underwent right subclavian vein catheterization. The catheter was mistakenly placed in the brachiocephalic trunk, with its tip in the ascending aorta, as confirmed by computed tomography (CT) and digital subtraction angiography (DSA). With the high surgical risk and the complexity of endovascular treatment, catheter replacement was chosen. One month after the initial placement, the catheter was replaced with a smaller one, and another month later, it was retracted without complications. Follow-up CT and DSA revealed no leakage, with the patient's vitals remaining stable. A three-month post-discharge phone follow-up confirmed the patient's continued stability.</p><p><strong>Conclusion: </strong>This case demonstrates the effective use of a catheter replacement technique as a minimally invasive repair method when other options are impractical. Ultrasound guidance is also recommended to improve the procedure's accuracy and safety.</p>\",\"PeriodicalId\":13967,\"journal\":{\"name\":\"International Journal of Emergency Medicine\",\"volume\":\"17 1\",\"pages\":\"145\"},\"PeriodicalIF\":2.0000,\"publicationDate\":\"2024-10-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11460035/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Emergency Medicine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1186/s12245-024-00744-9\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"EMERGENCY MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Emergency Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/s12245-024-00744-9","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"EMERGENCY MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

背景:中心静脉导管插入、监测、用药和液体复苏至关重要,通常使用锁骨下静脉、颈内静脉和股静脉。尽管其安全性一般,但动脉穿刺等并发症可能危及生命,需要快速诊断和治疗:一名 74 岁的妇女在脑梗塞恢复期接受了右锁骨下静脉导管插入术。经计算机断层扫描(CT)和数字减影血管造影(DSA)证实,导管被误置于肱脑干,其顶端位于升主动脉。由于手术风险高,血管内治疗复杂,因此选择了导管置换术。首次置入导管一个月后,更换了一根较小的导管,一个月后,导管回缩,未出现并发症。随访的 CT 和 DSA 显示没有渗漏,患者的生命体征保持稳定。出院后三个月的电话随访证实患者病情持续稳定:本病例展示了在其他方法不可行的情况下,导管置换技术作为微创修复方法的有效应用。此外,还建议使用超声引导,以提高手术的准确性和安全性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Minimally invasive approach to managing brachiocephalic trunk cannulation complicating central venous catheterization: a case report.

Background: Central venous catheterization, crucial for device insertion, monitoring, medication, and fluid resuscitation, commonly uses the subclavian, internal jugular, and femoral veins. Despite its general safety, complications like arterial puncture can be life-threatening, requiring rapid diagnosis and treatment.

Case presentation: A 74-year-old woman in the recovery phase of cerebral infarction underwent right subclavian vein catheterization. The catheter was mistakenly placed in the brachiocephalic trunk, with its tip in the ascending aorta, as confirmed by computed tomography (CT) and digital subtraction angiography (DSA). With the high surgical risk and the complexity of endovascular treatment, catheter replacement was chosen. One month after the initial placement, the catheter was replaced with a smaller one, and another month later, it was retracted without complications. Follow-up CT and DSA revealed no leakage, with the patient's vitals remaining stable. A three-month post-discharge phone follow-up confirmed the patient's continued stability.

Conclusion: This case demonstrates the effective use of a catheter replacement technique as a minimally invasive repair method when other options are impractical. Ultrasound guidance is also recommended to improve the procedure's accuracy and safety.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.60
自引率
0.00%
发文量
63
审稿时长
13 weeks
期刊介绍: The aim of the journal is to bring to light the various clinical advancements and research developments attained over the world and thus help the specialty forge ahead. It is directed towards physicians and medical personnel undergoing training or working within the field of Emergency Medicine. Medical students who are interested in pursuing a career in Emergency Medicine will also benefit from the journal. This is particularly useful for trainees in countries where the specialty is still in its infancy. Disciplines covered will include interesting clinical cases, the latest evidence-based practice and research developments in Emergency medicine including emergency pediatrics.
期刊最新文献
Successful transcatheter treatment of large right pulmonary artery to left atrial fistula: a case series and literature review. Airway, breathing, cellphone: a new vital sign? Impact of online expert interview-based research training on medical trainees' knowledge and confidence: a mixed-methods design. Fundamentals of emergency care support: a blended learning model to improve emergency and trauma care in a low-income country. Unveiling three accessory spleens in one patient: a rare case report and literature review.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1