质子治疗扫描光束传输系统物理参数的实验研究和定量分析

IF 0.4 4区 物理与天体物理 Q4 PHYSICS, MULTIDISCIPLINARY Moscow University Physics Bulletin Pub Date : 2024-10-09 DOI:10.3103/S0027134924700644
V. A. Kiselev, A. P. Chernyaev, Yu. D. Udalov, M. A. Belikhin, A. M. Demidova, S. E. Gritsenko
{"title":"质子治疗扫描光束传输系统物理参数的实验研究和定量分析","authors":"V. A. Kiselev,&nbsp;A. P. Chernyaev,&nbsp;Yu. D. Udalov,&nbsp;M. A. Belikhin,&nbsp;A. M. Demidova,&nbsp;S. E. Gritsenko","doi":"10.3103/S0027134924700644","DOIUrl":null,"url":null,"abstract":"<p>The development of proton therapy techniques imposes strict requirements for the accuracy of proton beam delivery. Existing methods for determining the planning target volume allow one to take into account only the influence of patient positioning errors before the start of irradiation. In this paper, the results of work on taking into account proton therapy system beam delivery errors for determining the planning target volume are presented. The technique for measuring the proton beam parameters and analyzing the measurement results is described. The calculation of the minimum required margin from the clinical target volume is carried out to guarantee its irradiation, taking into account the errors in beam delivery by the proton therapy system.</p>","PeriodicalId":711,"journal":{"name":"Moscow University Physics Bulletin","volume":"79 4","pages":"516 - 523"},"PeriodicalIF":0.4000,"publicationDate":"2024-10-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Experimental Study and Quantitative Analysis of the Physical Parameters of the Proton Therapy Scanning Beam Delivery System\",\"authors\":\"V. A. Kiselev,&nbsp;A. P. Chernyaev,&nbsp;Yu. D. Udalov,&nbsp;M. A. Belikhin,&nbsp;A. M. Demidova,&nbsp;S. E. Gritsenko\",\"doi\":\"10.3103/S0027134924700644\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>The development of proton therapy techniques imposes strict requirements for the accuracy of proton beam delivery. Existing methods for determining the planning target volume allow one to take into account only the influence of patient positioning errors before the start of irradiation. In this paper, the results of work on taking into account proton therapy system beam delivery errors for determining the planning target volume are presented. The technique for measuring the proton beam parameters and analyzing the measurement results is described. The calculation of the minimum required margin from the clinical target volume is carried out to guarantee its irradiation, taking into account the errors in beam delivery by the proton therapy system.</p>\",\"PeriodicalId\":711,\"journal\":{\"name\":\"Moscow University Physics Bulletin\",\"volume\":\"79 4\",\"pages\":\"516 - 523\"},\"PeriodicalIF\":0.4000,\"publicationDate\":\"2024-10-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Moscow University Physics Bulletin\",\"FirstCategoryId\":\"101\",\"ListUrlMain\":\"https://link.springer.com/article/10.3103/S0027134924700644\",\"RegionNum\":4,\"RegionCategory\":\"物理与天体物理\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"PHYSICS, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Moscow University Physics Bulletin","FirstCategoryId":"101","ListUrlMain":"https://link.springer.com/article/10.3103/S0027134924700644","RegionNum":4,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PHYSICS, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

摘要

质子治疗技术的发展对质子束输送的准确性提出了严格要求。现有的规划目标体积确定方法只能考虑照射开始前病人定位误差的影响。本文介绍了在确定规划靶体积时考虑质子治疗系统束流传输误差的工作成果。本文介绍了测量质子束参数和分析测量结果的技术。考虑到质子治疗系统的射束传输误差,计算了临床靶体积的最小所需余量,以保证靶体积的辐照。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Experimental Study and Quantitative Analysis of the Physical Parameters of the Proton Therapy Scanning Beam Delivery System

The development of proton therapy techniques imposes strict requirements for the accuracy of proton beam delivery. Existing methods for determining the planning target volume allow one to take into account only the influence of patient positioning errors before the start of irradiation. In this paper, the results of work on taking into account proton therapy system beam delivery errors for determining the planning target volume are presented. The technique for measuring the proton beam parameters and analyzing the measurement results is described. The calculation of the minimum required margin from the clinical target volume is carried out to guarantee its irradiation, taking into account the errors in beam delivery by the proton therapy system.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Moscow University Physics Bulletin
Moscow University Physics Bulletin PHYSICS, MULTIDISCIPLINARY-
CiteScore
0.70
自引率
0.00%
发文量
129
审稿时长
6-12 weeks
期刊介绍: Moscow University Physics Bulletin publishes original papers (reviews, articles, and brief communications) in the following fields of experimental and theoretical physics: theoretical and mathematical physics; physics of nuclei and elementary particles; radiophysics, electronics, acoustics; optics and spectroscopy; laser physics; condensed matter physics; chemical physics, physical kinetics, and plasma physics; biophysics and medical physics; astronomy, astrophysics, and cosmology; physics of the Earth’s, atmosphere, and hydrosphere.
期刊最新文献
Influence of Dimensional Quantization Effects on the Effective Mass of Major Charge Carriers in LED Heterostructures with In\({}_{\boldsymbol{x}}\)Ga\({}_{\boldsymbol{1-x}}\)N/GaN Multiple Quantum Wells Is the Cyclic Model of the Universe Possible in the Relativistic Theory of Gravitation? Experimental Assessment of Magnetic Resonance Imaging Distortion for Radiation Therapy Planning Orbital and Spin Parts of Angular Momentum Flux Density of Monochromatic Radiation in Nonabsorbing Media with Nonlocal Nonlinear Optical Response Temperature Changes in Luminescence of Mixed Complexes of Terbium and Samarium with Organic Ligands Based on 2,2\({}^{\boldsymbol{\prime}}\)-bipyridylcarboxamides
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1