{"title":"机器人辅助双叉韧带保留全膝关节置换术后,前交叉韧带损伤导致股骨和胫骨组件失效","authors":"Kosuke Shiga MD , Takao Kaneko MD, PhD , Ayakane Yamamoto MD , Kazuki Amemiya PT , Masaru Omata PT","doi":"10.1016/j.artd.2024.101523","DOIUrl":null,"url":null,"abstract":"<div><div>We report a case of failure of the femoral and tibial components due to anterior cruciate ligament (ACL) injury after robotic-assisted bicruciate-retaining total knee arthroplasty. A 70-year-old woman with osteoarthritis underwent robotic-assisted bicruciate-retaining total knee arthroplasty. At 8 months after surgery, persistent knee pain and swelling of the knee joint were noted after fall in knee. We diagnosed a failure between the femoral and tibial components following an ACL injury. Proximal ACL injury and spin out of ultra-high molecular weight polyethylene were confirmed. We selected a constrained condylar knee prosthesis due to large bone attribution after femoral and tibial component removal. Postoperative three-dimensional computed tomography images suggested that excessive internal rotational alignment of the tibial component caused stress on the ACL.</div></div>","PeriodicalId":37940,"journal":{"name":"Arthroplasty Today","volume":"30 ","pages":"Article 101523"},"PeriodicalIF":1.5000,"publicationDate":"2024-10-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Failure of the Femoral and Tibial Components Following Anterior Cruciate Ligament Injury After Robotic-Assisted Bicruciate-Retaining Total Knee Arthroplasty\",\"authors\":\"Kosuke Shiga MD , Takao Kaneko MD, PhD , Ayakane Yamamoto MD , Kazuki Amemiya PT , Masaru Omata PT\",\"doi\":\"10.1016/j.artd.2024.101523\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>We report a case of failure of the femoral and tibial components due to anterior cruciate ligament (ACL) injury after robotic-assisted bicruciate-retaining total knee arthroplasty. A 70-year-old woman with osteoarthritis underwent robotic-assisted bicruciate-retaining total knee arthroplasty. At 8 months after surgery, persistent knee pain and swelling of the knee joint were noted after fall in knee. We diagnosed a failure between the femoral and tibial components following an ACL injury. Proximal ACL injury and spin out of ultra-high molecular weight polyethylene were confirmed. We selected a constrained condylar knee prosthesis due to large bone attribution after femoral and tibial component removal. Postoperative three-dimensional computed tomography images suggested that excessive internal rotational alignment of the tibial component caused stress on the ACL.</div></div>\",\"PeriodicalId\":37940,\"journal\":{\"name\":\"Arthroplasty Today\",\"volume\":\"30 \",\"pages\":\"Article 101523\"},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2024-10-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Arthroplasty Today\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2352344124002085\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Arthroplasty Today","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2352344124002085","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
Failure of the Femoral and Tibial Components Following Anterior Cruciate Ligament Injury After Robotic-Assisted Bicruciate-Retaining Total Knee Arthroplasty
We report a case of failure of the femoral and tibial components due to anterior cruciate ligament (ACL) injury after robotic-assisted bicruciate-retaining total knee arthroplasty. A 70-year-old woman with osteoarthritis underwent robotic-assisted bicruciate-retaining total knee arthroplasty. At 8 months after surgery, persistent knee pain and swelling of the knee joint were noted after fall in knee. We diagnosed a failure between the femoral and tibial components following an ACL injury. Proximal ACL injury and spin out of ultra-high molecular weight polyethylene were confirmed. We selected a constrained condylar knee prosthesis due to large bone attribution after femoral and tibial component removal. Postoperative three-dimensional computed tomography images suggested that excessive internal rotational alignment of the tibial component caused stress on the ACL.
期刊介绍:
Arthroplasty Today is a companion journal to the Journal of Arthroplasty. The journal Arthroplasty Today brings together the clinical and scientific foundations for joint replacement of the hip and knee in an open-access, online format. Arthroplasty Today solicits manuscripts of the highest quality from all areas of scientific endeavor that relate to joint replacement or the treatment of its complications, including those dealing with patient outcomes, economic and policy issues, prosthetic design, biomechanics, biomaterials, and biologic response to arthroplasty. The journal focuses on case reports. It is the purpose of Arthroplasty Today to present material to practicing orthopaedic surgeons that will keep them abreast of developments in the field, prove useful in the care of patients, and aid in understanding the scientific foundation of this subspecialty area of joint replacement. The international members of the Editorial Board provide a worldwide perspective for the journal''s area of interest. Their participation ensures that each issue of Arthroplasty Today provides the reader with timely, peer-reviewed articles of the highest quality.